You may also be interested in
Safety module, Control panel, Safety controller, Safety switch, Emergency stop
Text version of the page
4
AS-Interface Safety at Work®
Safe transmission mechanism
The communication protocol for
safety relevant applications is
based on the unchanged ASInterface
Standard transmission.
With each AS-Interface master
call each safety device answers
in return with a preset data telegram.
This information is analysed
and in case of a deviation
from the pre-set values the
enabling paths are opened. The
maximum response time for a
safe shutdown is 40 ms.
Cost reduction with
AS-Interface Safety at Work
Reduce cost and installation
time – A never ending story.
During installation and machine
commissioning as well as during
maintenance, AS-Interface SaW
supports the user with integrated
system diagnosis. It provides
detailed information about
the cause and place of the failure,
and enables the user to
quickly find and analyse a malfunction
and therefore minimise
machine downtime. With ASInterface
Safety at Work you
can directly reduce your cost.
More flexibility with
AS-Interface Safety at Work
For the realisation of individual
safety solutions, SCHMERSAL
offers the maximum amount of
flexibility with its diverse range
of safety devices. Depending on
the application the user can
choose the optimal solution out
of an extensive product basket.
As AS-Interface SaW is an open
system, the user has also the
possibility to include additional
Safety components from other
suppliers. AS-Interface Safety
at Work fulfils the safety requirements
to the highest standards.
AS-Interface Safety at Work
(SaW) is the first safety bus
system based upon the open
standard of AS-International.
Safety components such as
Emergency Stop command
devices, safety switches, solenoid
interlocks or safety light
curtains are simply connected
to the yellow AS-Interface cable.
For the evaluation of the safety
signals a “Safety Monitor” is
merely added to the AS-Interface
system.
AS-Interface Standard in
accordance with EN 50295
With the integration of AS-Interface
SaW the AS-Interface network
will continue to operate
unchanged. The well known
components, like the standard
AS-Interface master, the standard
power supply as well as the
AS-Interface yellow cable will
still form the basis of all ASInterface
installations. Therefore
an existing machine can easily
be equipped with additional
AS-i SaW components.
The heart of safety
The safety monitor analyses all
transmitted information from
each safety device on the ASInterface
network and, in case of
a safety device being activated
or in case of a fault in one of the
safety devices, the safety monitor
immediately shuts down to
create a safe condition. The
safety monitor is equipped with
one or two redundant pairs of
enabling paths for applications
up to performance level e according
to EN ISO 13849-1.
Each safety function of the monitor
can be set with a simple drag
& drop software. Afterwards the
configuration is downloaded into
the safety monitor and protected
with a password.
AS-Interface SaW
Easy, safe and reliable
|
|