32 AST LC ST-AS • Input module for 2 monitored PNP semiconductor outputs for safety light curtains and light grids • AS-Interface LED and status display • AS-Interface M12 connector • Thermoplastic enclosure • Long life • Protection class IP 67 AST LC ST-AS Standards: EN 50295, EN 61496-1, EN ISO 13849-1, IEC 61508 Enclosure: glass-fibre reinforced thermoplastic, self-extinguishing AS-Interface connection type: connector M12 x 1 Protection class: IP 67 to IEC/EN 60529 AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof AS-Interface operating current: £ 50 mA AS-Interface specification: (V 2.1) Profile: S-0.B IO-Code: 0x0 ID-Code: 0xB ID-Code1: 0xF ID-Code2: 0xE AS-I inputs: contact 1: data bits D0 /D1 = static code 00 or dynamic code transmission contact 2: data bits D2 /D3 = static code 00 or dynamic code transmission Outputs: A0 ... A3 not used Parameter bits: P0 ... P3 not used Input module address: default on address 0, programmable via the AS-Interface Master or Hand-held programming device Indications: AS-Interface: voltage LED green, communication LED red, OSSD1/2; Enabling status: LED yellow Power supply for AOPD: PELV power supply to IEC 364-4-41 Response time: £ 20 ms EMC rating: conforming to EMC Directive Ambient temperature: – 25 °C … + 60 ºC Storage and transport temperature: – 25 °C … + 85 ºC Classification: Standards: EN ISO 13849-1; IEC 61508 PL: up to e Category: up to 4 PFH value: 1,74 x 10-9 /h SIL: up to 3 Service life: 20 years The addressing must take place via the cable end or the M12 connector. C 16,5 ca. 2000 2 70 66 25 ¤28 M30x1,5 ca. 500 ST1 ST2 Approvals F Connector male ST AS-Interface 1: AS-i + 2: spare 3: AS-i – 4: spare Connector male ST1 Supply voltage 1: + 24 VDC 2: spare 3: GND 4: spare 5: FE (shield) Connector female ST2 Connection AOPD 1: + 24 VDC 2: OSSD 1 3: GND 4: OSSD 2 5: FE (shield) 1 4 5 2 3 1 4 2 3 5 1 4 2 3 Ordering details Technical data Note Note R C S OR AS-Interface Safety at Work

pageCatalog pdf di En 2012-02-07-17