Note
• The wiring diagram is shown with guard
doors closed and in de-energised condition.
• The AST module can on be used for the
connection of potential-free contacts. Additional
LED’s on the connecting wire are not
acceptable.
• Monitoring a sliding guard door using two
position switches with safety function. The
NC contact must have positive break when
the guard door is opened.
• The module AST...AS is monitored by the ASInterface.
The locking solenoid is powered by
an external power supply. Connection to the
AS-Interface and the auxiliary power is made
via a single M12 connector or via a 4-pole
connecting cable.
• The passive connection module (see page 35)
links up the external solenoid power supply
(auxiliary power supply, black cable) and the
AS-i network connection (yellow cable) to a
single M12 connector. A 4-wired cable makes
the connection to the AST…ST6 module.
• An internal output controls the solenoid operation.
Depending on the interlocking device,
output bit A0 locks or unlocks the actuator.
Output bit A0 has the same address as the
safety inputs.
Wiring diagram
AST 02
ST 2
BN BN
BU BU
AST 11
ST 6
13 14 21 22
BN BU WH BK RD GY
A1 A2
Sensor connection
AS-i connection
Sensor connection
AS-i connection
z.B. AZM 170-11z
R C
S OR
AS-Interface Safety at Work
|
|