28
R C
S OR
AS-Interface Safety at Work
AZM 170 AS Technical data
ø 4,2
22
15
90
31
60
23
8
30
30
8
M12 37
• Solenoid interlock in 2 versions:
AZM 170 B ST-AS:
Release, when door is closed
AZM 170 BZ ST-AS:
AS-i split code 1, when door is closed
AS-i split code 2, when door is locked
• High holding force 1,000 N
• Integrated AS-Interface
• AS-Interface LED and status display
• AS-Interface M12 connector
• AS-Interface magnet control
• Solenoid power supply via 24 VDC
• Manual release for power to unlock
• Protection class IP 67
Ordering details
Technical data
Note
Manual release from side
• For manual release using M5 triangular key,
available as accessory
• Only available for power to unlock principle
• Ordering suffix -2197
AZM 170 À ST-AS ÁÂPÃ
Nr. Option Beschreibung
À B Actuator monitored
BZ Combined monitoring of
actuator/solenoid interlock
Á Latching force 5 N
R Latching force 30 N
 Power to unlock
A Power to lock
à 2197 Manual release for power
to unlock
Ambient conditions:
Ambient temperature: – 25 °C … + 55
ºC
Storage and transport
temperature: – 25 °C … + 85 °C
Relative humidity: 30% … 95%,
non-condensing, non-icing
Resistance to vibration: 10 ... 150 Hz,
amplitude 0.35 mm
Resistance to shock: 30 g / 11 ms
Switching frequency f: £ 1 Hz
Switch-off delay: < 100 ms
Actuating speed: £ 2 m/s
Classification: *approvals under
preparation
If a fault exclusion for hazardous damage
of the 1-channel mechanics is authorized
and an adequate protection against tampering
is ensured, suitable for use up to:
Standards: EN ISO 13849-1; IEC 61508
PL: up to d
Category: up to 3
PFH value: 1,01 x 10-7 /h
for max. 100.000 operations/year
SIL: up to 2
Service life: 20 years
Basically suitable up to:
Standards: EN ISO 13849-1; IEC 61508
PL: up to c
Category: up to 1
PFH value: 1,16 x 10-6 /h
for max. 100.000 operations/year
SIL: up to 1
Service life: 20 years
Note
The solenoid interlock and the actuator unit
must be ordered separately!
Interlocks with power to lock principle may
only be used after a thorough evaluation of the
accident risk, since the safety guard can be
opened immediately on failure of the power
supply or upon activation of the main switch.
The addressing must take place via
the M12 connector.
1: AS-i +
2: Aux – (P)
3: AS-i –
4: Aux + (P)
1 4
2 3
C
Approvals
F* *
* under preparation
Standards: EN 50295, EN 60947-5-1,
EN ISO 13849-1, IEC 61508
Enclosure: glass-fibre reinforced
thermoplastic, self-extinguishing
Actuator and locking bolt: stainless steel
Mechanical life: ³ 1 million operations
Fmax: 1000 N
Holding force: typically 30 N for suffix R
Protection class: IP 67 to IEC/EN 60529
Protection class: II, X
Overvoltage category: III
Degree of pollution: 3
Connection: Connector M12, 4 poles
Electrical data AS-Interface:
Operating voltage: 26.5 ... 31.6 VDC,
via AS-Interface, reverse-polarity proof
Operating current: max. 0,1 A
AS-Interface specification:
(V 2.1) Profile S-7.B
IO-Code 0x7
ID-Code 0xB
ID-Code1: 0xF
ID-Code2 0xE
AS-I inputs: Data bits D0 ... D3:
static code 0 or dynamic
code transmission
AS-I outputs:
Bit 0 Solenoid control
Bit 1 ... Bit 3 not used
Parameter port:
P0: Actuator present
P1: Interlock locked
P2: no function
P3: no function
Input module address: preset to address 0,
can be modified by means of the
AS-Interface bus master or
the hand programming device
Diagnostic display:
LED grün AS-i supply voltage on
LED rot AS-i communication error
or slave address = 0
LED gelb Enabling status
Auxiliary voltage (Aux):
Operating voltage: 24 VDC (– 15% / + 10%)
(stabilised PELV)
Operating current: max. 0,5 A
Magnet: 100% ED
Device fuse: £ 4 A
when used to UL 508
|
|