24 R C S OR AS-Interface Safety at Work MZM 100 AS 40 40 1 92 68 167 11,5 32 13 4 M12 28 Ordering details MZM 100 À ST-AS ÁÂ AP No. Option Description À Interlock monitored B Actuator monitored Á Without latching (only for variant “interlock monitored“) R Latching force variable approx. 30 N … 170 N Â Without permanent magnet M With permanent magnet approx. 30 N A Power to lock P Supply through auxiliary voltage Technical data Auxiliary voltage: Operating voltage: 24 VDC –15%/+10% (stabilised PELV) Operating current: max. 0.6 A Magnet: 100% ED Ambient conditions: Ambient temperature: – 25 °C … + 55 ºC Storage and transport temperature: – 25 °C … + 85 ºC Relative humidity: 30% … 95%, non-condensing, non-icing Resistance to vibration: 10 ... 150 Hz amplitude 0.35 mm / 5 g Resistance to shock: 30 g / 11 ms Switching frequency f: 1 Hz Response time: < 100 ms Duration of risk: < 100 ms Time to readiness: < 4 s Classification: Standards: EN ISO 13849-1; IEC 61508; IEC 60947-5-3 PL: up to e Category: up to 4 PFH value: 5,0 x 10-9 /h SIL: up to 3 Service life: 20 years Classification: PDF-M Technical data Connecting Addressing through M12 connector. 1: AS-Interface + 2: Aux – (p) 3: AS-Interface – 4: Aux + (p) 1 4 2 3 Note The solenoid interlock and the actuator unit must be ordered separately! Interlocks with power to lock principle may only be used after a thorough evaluation of the accident risk, since the safety guard can be opened immediately on failure of the power supply or upon activation of the main switch. Approvals F* C Misalignment ± 5 mm ± 3 mm • Safety switchgear in 2 variants MZM 100 ST-AS …: Solenoid interlock MZM 100 B ST-AS …: Safety switch with supplementary guard locking function • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally • Power-to-lock principle • Holding force ³ 500 N • Adjustable latching force 30 N … 170 N • Integrated AS-Interface • AS-Interface LED and status display • AS-Interface M12 connector • AS-Interface magnet control • External magnet voltage supply • Intelligent diagnosis functions • Protection class IP 67 • Easy to clean • Suitable for applications: - up to PL e/category 4 to EN ISO 13849-1 - up to SIL 3 to IEC 61508 * under preparation Standards: EN 50295, IEC 60947-5-3, EN ISO 13849-1, IEC 61508 Enclosure: glass-fibre reinforced thermoplastic, self-extinguishing Mechanical life: ³ 1 million operations (for guards £ 5 kg; actuating speed £ 0.5 m/s) Fmax : 500 N Holding force: approx. 30 N … 170 N Protection class: IP 67 to IEC/EN 60529 Protection class: II, X Overvoltage category: III Degree of pollution: 3 Connection: Connector M12 x 1, 4 poles Electrical data AS-Interface: Operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof Operating current: 0.1 A AS-Interface specification: (V 2.1) Profile S-7.B IO-Code 0x7 ID-Code 0xB ID-Code1: 0xF ID-Code2 0xE Inputs: Data bits D0 ... D3: static code 0 or dynamic code transmission Outputs: Bit 0 Solenoid control Bit 1 ... Bit 3 adjustment latching force, steps with 20 N Parameter port: P0: Actuator present P1: Door locked P2: Auxiliary voltage on P3: Error detected Input module address: preset to address 0, can be modified by means of the AS-Interface bus master or the hand programming device Diagnostic display: LED green/red AS-i supply voltage on/ AS-i communication error/ Slave address = 0 LED yellow Device status LED red Device error

pageCatalog pdf di En 2012-02-07-17