AS-Interface Safety at Work
AZM 200 AS
40
220
155,5
5
6,5
32,5
37,7
7,5
3,3
20 ± 1
M12
Ordering details
AZM 200 À ST-T-AS ÁP
No. Option Description
À Interlock monitored
B Actuator monitored
BZ Combined monitoring of
the actuator/interlock
Á Power to unlock
A Power to lock
P Magnet supply through
auxiliary voltage
Technical data
Ambient conditions:
Ambient temperature: – 25 °C … + 60 ºC
Storage and transport
temperature: – 25 °C … + 85 ºC
Relative humidity: 30% … 95%,
non-condensing, non-icing
Resistance to vibration: 10 ... 150 Hz
amplitude 0.35 mm / 5 g
Resistance to shock: 30 g / 11 ms
Switching frequency f: 1 Hz
Response time: 1 million operations
Holding force Fmax.: 2000 N
Latching force: typically 30 N
Protection class: IP 67 to IEC/EN 60529
Insulation protection class: II, X
Overvoltage category: III
Degree of pollution: 3
Connection: connector M 12 x 1, four pole
Electrical data AS-Interface:
Operating voltage: 26.5 ... 31.6 VDC,
via AS-Interface,
reverse-polarity proof
Operating current: 0.1 A
AS-Interface specification:
(V 2.1) Profile S-7.B
IO-Code 0x7
ID-Code 0xB
ID-Code1: 0xF
ID-Code2 0xE
Inputs: Data bits D0 ... D3:
static code 0 or dynamic
code transmission
Outputs:
Bit 0 Solenoid control
Bit 1 ... Bit 3 not used
Parameter port:
P0: Door and actuator detected
P1: Door locked
P2: Solenoid voltage within tolerance range
P3: Error detected
Input module address: preset to address 0,
can be modified by means of the
AS-Interface bus master or
the hand programming device
Diagnostic display:
LED green/red AS-i supply voltage on/
AS-i communication error/
Slave address = 0
LED yellow Device status
LED red Device error
Magnet auxiliary voltage:
Operating voltage: 24 VDC –15%/+10%
(stabilised PELV)
Operating current: max. 0.5 A
Magnet: 100% ED
C
Approvals
F
• Solenoid interlock in 3 versions:
AZM 200 ST-T-AS:
Release, when door is locked
AZM 200 B ST-T-AS:
Release, when door is closed
AZM 200 BZ ST-T-AS:
AS-i split code 1, when door is closed
AS-i split code 2, when door is locked
• With integrated guard detection sensor
• Integrated AS-Interface
• AS-Interface LED and status display
• AS-Interface M12 connector
• AS-Interface magnet control
• External magnet voltage supply
• Sensor technology permits an offset
between actuator and interlock of ± 5 mm
• High holding force 2000 N
• Intelligent diagnosis
• Manual release
• Suitable for applications:
- up to PL e/category 4 to EN ISO 13849-1
- up to SIL 3 to IEC 61508
|
|