20 R C S OR AS-Interface Safety at Work AZM 200 AS 40 220 155,5 5 6,5 32,5 37,7 7,5 3,3 20 ± 1 M12 Ordering details AZM 200 À ST-T-AS ÁP No. Option Description À Interlock monitored B Actuator monitored BZ Combined monitoring of the actuator/interlock Á Power to unlock A Power to lock P Magnet supply through auxiliary voltage Technical data Ambient conditions: Ambient temperature: – 25 °C … + 60 ºC Storage and transport temperature: – 25 °C … + 85 ºC Relative humidity: 30% … 95%, non-condensing, non-icing Resistance to vibration: 10 ... 150 Hz amplitude 0.35 mm / 5 g Resistance to shock: 30 g / 11 ms Switching frequency f: 1 Hz Response time: 1 million operations Holding force Fmax.: 2000 N Latching force: typically 30 N Protection class: IP 67 to IEC/EN 60529 Insulation protection class: II, X Overvoltage category: III Degree of pollution: 3 Connection: connector M 12 x 1, four pole Electrical data AS-Interface: Operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof Operating current: 0.1 A AS-Interface specification: (V 2.1) Profile S-7.B IO-Code 0x7 ID-Code 0xB ID-Code1: 0xF ID-Code2 0xE Inputs: Data bits D0 ... D3: static code 0 or dynamic code transmission Outputs: Bit 0 Solenoid control Bit 1 ... Bit 3 not used Parameter port: P0: Door and actuator detected P1: Door locked P2: Solenoid voltage within tolerance range P3: Error detected Input module address: preset to address 0, can be modified by means of the AS-Interface bus master or the hand programming device Diagnostic display: LED green/red AS-i supply voltage on/ AS-i communication error/ Slave address = 0 LED yellow Device status LED red Device error Magnet auxiliary voltage: Operating voltage: 24 VDC –15%/+10% (stabilised PELV) Operating current: max. 0.5 A Magnet: 100% ED C Approvals F • Solenoid interlock in 3 versions: AZM 200 ST-T-AS: Release, when door is locked AZM 200 B ST-T-AS: Release, when door is closed AZM 200 BZ ST-T-AS: AS-i split code 1, when door is closed AS-i split code 2, when door is locked • With integrated guard detection sensor • Integrated AS-Interface • AS-Interface LED and status display • AS-Interface M12 connector • AS-Interface magnet control • External magnet voltage supply • Sensor technology permits an offset between actuator and interlock of ± 5 mm • High holding force 2000 N • Intelligent diagnosis • Manual release • Suitable for applications: - up to PL e/category 4 to EN ISO 13849-1 - up to SIL 3 to IEC 61508

pageCatalog pdf di En 2012-02-07-17