16 R C S OR AS-Interface Safety at Work AZ 16 AS 14 M 12 M 12 52 5,5 15,5 7 18 8 29 90 8 40 13 9 30 • Safety switch with separate actuator • Integrated AS-Interface interface • AS-Interface LED and status display • AS-Interface M12 connector • Thermoplastic enclosure • Coded actuator • Long life • Protection class IP 67 Approvals F Ordering details AZ 16À-ASÁ No. Option Description À ST1 Connector (middle) ST2 Connector (right) ST3 Connector (left) Á No latching R Latching 30 N R-2254 Latching 5 N Technical data Standards: EN 50295, EN 60947-5-1, EN ISO 13849-1, IEC 61508 Enclosure: glass-fibre reinforced thermoplastic, self-extinguishing AS-Interface connection type: connector M12 x 1 Protection class: IP 67 AS-Interface operating voltage: 26.5 ... 31.6 VDC, via AS-Interface, reverse-polarity proof AS-Interface operating current: £ 50 mA AS-Interface specification: (V 2.1) Profile: S-0.B IO-Code: 0x0 ID-Code: 0xB ID-Code1: 0xF ID-Code2: 0xE AS-I inputs: contact 1: data bits D0 /D1 = static code 00 or dynamic code transmission contact 2: data bits D2 /D3 = static code 00 or dynamic code transmission Parameter bits: P0 … P3 not used Input module address: default on address 0, programmable via the AS-Interface Master or Hand-held programming device Indications: AS-Interface: voltage LED green, communication LED red Enabling status: LED yellow Mechanical life: > 1 million operations EMC rating: conforming to EMC Directive Ambient temperature: – 25 °C … + 60 ºC Storage and transport temperature: – 25 °C … + 85 ºC Note The addressing must take place via the M12 connector. 1: AS-i + 2: spare 3: AS-i – 4: spare 1 4 2 3 C Technical data Classification: If a fault exclusion for hazardous damage of the 1-channel mechanics is authorized and an adequate protection against tampering is ensured, suitable for use up to: Standards: EN ISO 13849-1; IEC 61508 PL: up to d Category: up to 3 PFH value: 1,01 x 10-7 /h for max. 100.000 operations/year SIL: up to 2 Service life: 20 years Basically suitable up to: Standards: EN ISO 13849-1; IEC 61508 PL: up to c Category: up to 1 PFH value: 1,14 x 10-6 /h for max. 100.000 operations/year SIL: up to 1 Service life: 20 years Note Actuators must be ordered separately.

pageCatalog pdf di En 2012-02-07-17