You may also be interested in
Control foot-switch, Proximity switch, Solenoid interlock, Control device, Safety relay
Text version of the page
15
R C
S OR
AS-Interface Safety at Work
T. 235-AS
6
25
12 10
3,5
22
13,5
30
20
30
63,5
20 8,5
20
4,3
22
• Integrated AS-Interface
• AS-Interface LED and status display
• AS-Interface M12 connector
• Metal enclosure
• Slow action
• Wide range of alternative actuators
• Actuator heads can be repositioned
by 4 x 90°
• Angle of roller lever adjustable in 10° steps
• Good resistance to oil and petroleum spirit
• Protection class IP 67
Ordering details
Technical data
Standards: EN 50295, EN 60947-5-1,
EN ISO 13849-1, IEC 61508
Design: fixings to EN 50047
Enclosure: zinc die-cast, enamelled
Switching system: slow action, positive
break NC contacts A
AS-Interface connection type: connector
M12 x 1
Protection class: IP 67 to IEC/EN 60529
AS-Interface
operating voltage: 26.5 ... 31.6 VDC,
via AS-Interface,
reverse-polarity proof
AS-Interface
operating current: AS electronics: £ 50 mA
AS-Interface specification:
(V 2.1) Profile: S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code1: 0xF
ID-Code2: 0xE
AS-I inputs:
contact 1: data bits D0 /D1 = static code 00
or dynamic code transmission
contact 2: data bits D2 /D3 = static code 00
or dynamic code transmission
Outputs: A0 ... A3 not used
Parameter bits: P0 ... P3 not used
Input module address: Default on address 0
Indications:
AS-Interface: voltage LED green,
communication LED red
Enabling status: LED yellow
Mechanical life: > 1 million operations
Switching frequency: max. 5000/h
EMC rating: conforming to
EMC Directive
Ambient temperature: – 25 °C … + 60 ºC
Storage and transport
temperature: – 25 °C … + 85 ºC
Note
The addressing must take place via
the M12 connector.
1: AS-i +
2: spare
3: AS-i –
4: spare
5: FE (shield)
1 4
2 3
5
C
TÀ 235-AS-ST
No. Option Description
À R Roller plunger R
A selection of actuators can
be found in the Main catalogue
„Safety technology“
Approvals
F
Technical data
Classification:
Standards: EN ISO 13849-1; IEC 61508
PL: up to c
Category: up to 1
PFH value: 1,14 x 10-6 /h
for max. 1.000.000 operations/year
SIL: up to 1
Service life: 20 years
When 2 safety switches with mutual
monitoring are used and provided that an
adequate protection against tampering is
installed, then suitable up to:
PL: up to e
Category: up to 4
PFH value: 2,5 x 10-8 /h
for max. 1.000.000 operations/year
SIL: up to 3
Service life: 20 years
|
|