You may also be interested in
Light barrier, Safety switch, Safety light curtain, Magnetic switch, Emergency stop
Text version of the page
13
R C
S OR
AS-Interface Safety at Work
BNS 36 AS
6
25
13
4,5
ø4,5
6
78
88
• Safety sensor
• Integrated AS-Interface interface
• AS-Interface LED and status display
• Available with M12 plug-in connector
and pre-wired cable
• Thermoplastic enclosure
• Coded actuator
• Long life, no mechanical wear
• Insensitive to transverse misalignment
• Concealed mounting possible
• Insensitive to soiling
• Protection class IP 67
Ordering details
BNS 36 À-AS-Á
No. Option Description
À Cable 2 m
STG Cable with straight
connector M12
STW Cable with angled
connector M12
Á L Left hand door
R Right hand door
Technical data
Note
System components
18,5 3
25
5
7
4,5 6
88
78
ø5
6
25
13
4,5
ø4,5
6
78
88
Actuating magnets BPS 36-1/-2
Spacer BNS 36
Left hand door
Right hand door
Ordering details
Actuating magnets
Standard BPS 36-1
Mounting angle of 90° BPS 36-2
Spacer Distanzstück BNS 36
The actuators for the magnetic safety sensors
must be ordered separately.
The addressing must take place via the cable
end or the M12 connector.
1: AS-i +
2: spare
3: AS-i –
4: spare
1 4
2 3
C
Approvals
F
0
2
4
7
3
6
5,3
6
6,5
7
7,5
8
4,5
1
3
5
0
2
4
7
3
6
5,3
6
6,5
7
7,5
8
4,5
1
3
5
BPS 36-1
BPS 36-2
Switch on/off diagram
Standards: EN 50295, IEC 60947-5-3,
EN ISO 13849-1, IEC 61508
Enclosure: glass-fibre reinforced thermoplastic
Design: rectangular
Mode of operation: magnetic
AS-Interface connection type: cable LSYY (2 m);
or cable (2 m) with connector M12, 4 poles
Protection class: IP 67
Ambient temperature: – 25 °C … + 60 ºC
Storage/transport temp.: – 25 °C … + 70 °C
Resistance to vibration: 10 … 55 Hz,
amplitude 1 mm
Resistance to shock: 30 g / 11 ms
Switching frequency f: £ 1 Hz
Assured operation distance Sao: 7 mm
Assured release distance Sar: 17 mm
Electrical data AS-Interface:
AS-I operating voltage: 26.5 ... 31.6 VDC,
via AS-Interface, reverse-polarity proof
AS-Interface operating current: £ 0,05 A
AS-I specification: Profile: S-0.B
(V 2.1) IO-Code: 0x0
ID-Code: 0xB
ID-Code1: 0xF
ID-Code2: 0xE
AS-I inputs:
contact 1: data bits D0 /D1 = static code 00
or dynamic code transmission
contact 2: data bits D2 /D3 = static code 00
or dynamic code transmission
AS-i Parameter port: P0 … P3: no function,
set parameter outputs “1111” (0xF)
AS-i input module address: default on
address 0, programmable via the AS-Interface
Master or Hand-held programming device
Diagnostic indication:
AS-i LED green AS-Interface supply voltage on
AS-i LED red AS-Interface communication error
or slave address = 0
LED yellow enabling status
Classification:
Standards: EN ISO 13849-1; IEC 61508;
IEC 60947-5-3
PL: up to e
Category: up to 4
PFH value: 1,24 x 10-8 /h
for max. 500.000 operations/year
SIL: up to 3
Service life: 20 years
Classification: PDF-M
|
|