You may also be interested in
Relay, Magnetic switch, Emergency stop, Light barrier, Safety switch
Text version of the page
12
AS-Interface Safety at Work R C
S OR
BNS 260 AS
26
6
2000
13
4 36
19
22
¤ 4,5
LED
• Safety sensor
• Integrated AS-Interface interface
• AS-Interface LED
• Available with M12 plug-in connector
and pre-wired cable
• Thermoplastic enclosure
• Coded actuator
• Long life, no mechanical wear
• Insensitive to transverse misalignment
• Concealed mounting possible
• Insensitive to soiling
• Protection class IP 67
Approvals
F
Ordering details
Technical data
Standards: EN 50295, IEC 60947-5-3,
EN ISO 13849-1, IEC 61508
Enclosure: glass-fibre reinforced
thermoplastic
AS-Interface
connection type: cable LSYY (black)
Cable section: 2 x 0.24 mm2
Protection class: IP 67
AS-Interface
operating voltage: 26.5 ... 31.6 VDC,
via AS-Interface, reverse-polarity proof
AS-Interface operating current: £ 50 mA
AS-Interface specification:
(V 2.1) Profile: S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code1: 0xF
ID-Code2: 0xE
AS-I inputs:
contact 1: data bits D0 /D1 = static code 00
or dynamic code transmission
contact 2: data bits D2 /D3 = static code 00
or dynamic code transmission
Parameter bits: P0 … P3 not used
Input module address: Default on address 0,
programmable via the
AS-Interface Master or
Hand-held programming device
Indications: AS-Interface: voltage LED green,
communication LED orange
Mode of operation: magnetic
Sao: 5 mm
Sar: 15 mm
Repeat accuracy: R £ 0,1 Sao
Switching frequency f: < 1 Hz
Actuating magnet: BPS 260, coded
EMC rating: conforming to EMC Directive
Ambient temperature: – 25 °C … + 60 ºC
Storage and transport
temperature: – 25 °C … + 70 ºC
Classification:
Standards: EN ISO 13849-1; IEC 61508;
IEC 60947-5-3
PL: up to e
Category: up to 4
PFH value: 6,21 x 10-9 /h
for max. 500.000 operations/year
SIL: up to 3
Service life: 20 years
Classification: PDF-M
Note Ordering details
Actuating magnets
Standard BPS 260-1
Mounting angle of 90° BPS 260-2
Spacer Distanzstück BNS 260
The actuators for the magnetic safety sensors
must be ordered separately.
The addressing must take place via the
cable end or the M12 connector.
1: AS-Interface +
2: spare
3: AS-Interface –
4: spare
1 4
2 3
C
BNS 260À-AS-Á
No. Option Description
À 2 m cable
STG 2 m cable with
straight plug M12
STW 2 m cable with
angled plug M12
Á L Left hand door
R Right hand door
System components
5
22
19
¤ 4,5
36
26
13
6
36
26
19
22
¤4,5
Actuating magnets BPS 260-1/-2
Spacer BNS 260
Left hand door
Right hand door
3,5
3,5
3,5
3,5
3,5
3
3
4
5
2
1
0
5
5
5
4
3
2
3,5
3,5
3,5
3,5
3,5
3
3
4
5
2
1
0
5
5
5
4
3
2
BPS 260-1
BPS 260-2
Switch on/off diagram
|
|