You may also be interested in
Control device, Controller, Emergency stop, Control foot-switch, Position switch
Text version of the page
11
R C
S OR
AS-Interface Safety at Work
ASM G2
Approvals
F *
Ordering details
Technical data
Standards: EN 50295, EN ISO 13849-1,
IEC 61508
Response time: < 40 ms
Switch-on time: < 10 s
AS-i specification: profile: S-7.5.5
Enclosure: stainless steel
Dimensions (L/W/H): 120 x 85 x 96 mm
Weight: approx. 800 g
Mounting: onto standard DIN rails
Screw terminals: max. 2 x 1.5 mm2
Electrical data:
AS-i operating voltage: 26.5 ... 31.6 VDC
Power consumption
from AS-i: approx. 250 mA or
external supply
Operating voltage: 24 VDC ± 15 %
Power consumption 24 VDC: approx. 200 mA
Power consumption from AS-i: approx. 50 mA
Insulation voltage: ³ 500 V
Inputs: 4 inputs, supplied from AS-i,
as EDM or start inputs
Outputs: each time 2 output
switching elements, for
enabling paths 1 and 2
Contact load capacity: 3 A DC-13 at 30 V
3 A AC-15 at 30 V
Diagnostic indications:
LCD AS-i status and error indications
LED green Power
LED green/red U AS-i / Fault
LED yellow Ready
LED green Channel 1
LED green Channel 2
Ambient conditions:
Operating temperature: 0 °C … + 55 ºC
Storage and transport
temperature: – 25 °C … + 85 °C
Protection class: IP 20 to IEC/EN 60529
Resistance to vibrations: to EN 61131-2
Resistance to shocks: to EN 61131-2
Classification:
Standards: EN ISO 13849-1; IEC 61508
PL: up to e
Category: up to 4
PFH value: 5,4 x 10-9 /h
SIL: up to 3
Service life: 20 years
Note
For the configuration with the asimon software,
a PC or laptop is required.
Hardware requirements:
• A Pentium® Intel® processor or faster (e.g.
compatible models, e.g. AMD® or Cyrix®)
• A CD-ROM player
• At least 32 MB RAM and 32 MB HDD
• A free RS 232 (serial) interface with 9-pole
SubD-connector
(Using a USB-RS 232 interface convertor
or a serial interface card could cause communication
problems with the safety monitor)
Operating system:
• Microsoft® Windows 2000 / XP / Vista®
Ordering details
Configuration cable ASM G2-CC
with PS2 connector and
SUBD 9 connector,
Length: 1.8 meter
asimon G2 software package ASM G2-CD
Configuration and diagnostic
software version 3.x with
documentation on CD-ROM
C
Safety monitor ASM G2-R2/R2
for 2 AS-i circuits and for
up to 16 enabling paths
* Note:
UL/CSA: Class 2 power-supply only
System components
Configuration cable ASM G2-CC
Configuration software asimon G2 V 3.x
Software asimon G2 for the configuration,
commissioning and diagnostics of the
AS-Interface ASM G2 safety monitor
• Safety monitor for 2 AS-i circuits
• Monitoring of up to 62 safe AS-i slaves,
e.g.: safety switches, solenoid interlocks,
emergency stop devices, two-hand controls,
light curtains and light grids, etc.
• 256 function blocks (devices) possible
• Control of up to 16 redundant enabling
paths, 2 internally in the device and
up to 14 external safe AS-i outputs
• Mains coupling of 2 AS-i circuits
• LCD diagnostic display with 4 buttons
• Configurable monitoring modules for
different safety switchgear
• Filter functions for bouncing safety guards
• Integrated muting module
• Other functions:
AND-operations, OR-operations,
start modules, on-site reset, start-up test,
stop categories 0 & 1
• START inputs: start functions through
external button
• EDM inputs: connection of feedback circuits
to monitor external contactors
• LED status indication
• AS-i system connection
• Suitable for applications:
- up to PL e/category 4 to EN ISO 13849-1
- up to SIL 3 to IEC 61508
- PFH: 5,4 x 10-9 / h
|
|