You may also be interested in
Safety device, Emergency stop switch, Modular controller, Controller, Control device
Text version of the page
R C
S OR
10
AS-Interface Safety at Work
asimon version 3.x
The asimon software is a tool for the
configuration and commissioning of the
AS-Interface safety monitor.
The configuration of the safety monitor and its
safety devices, i.e. E-Stop buttons, solenoid
interlocks, safety switches, 2-Hand controls,
light curtains etc. is performed by an easyto-
use graphical interface. Thus providing
safeguarding of hazardous areas present by
power-driven machinery.
Approvals
F
Ordering details
ASM-startup-package: SET ASM-SWP
Configuration and diagnostic
software package with
online documentation on
CD-ROM, a configurationand
downloadcable
asimon software package: ASM-CD
Configuration and diagnostic
software package with online
documentation on CD-ROM
The asimon offers the user a library of icons
representing different safety devices and other
functional devices. For the implementation of
a new safety application the required safety
devices are selected from the icon library,
configured and assigned to the respective
enabling path.
Following the successful configuration and
download, the safety monitor and the safety
devices can be tested and monitored with
asimon.
Besides the classic representation in table
form, a representation as logical diagram
(FUP) can be chosen as well.
The following functions are available with
the asimon software:
• Configuration of different safety devices
• Configuration of different filter functions
for bouncing safety guards
• Configuration of start-modules
• Configuration logical combinations
(AND, OR, RS Flip-Flops)
• Configuration of the feedback loops
• Configuration of the operating methods
• Configuration of the system-modules
• Print out of Configuration protocol
Asimon can be used offline as well as online
during development and project planning.
The configuration files can be saved and
loaded as desired.
The software is compatible with the
Microsoft® operating system
Windows 95/98/ME/NT/2000/XP/Vista®.
Note
Hardware requirements:
• A Pentium®- Intel® processor of faster
(or compatible models, e.g. AMD® or Cyrix®)
• At least 32 Mb free random-access memory
(RAM)
• At least 32 Mb free disk space
• A CD-ROM player
• A free RS 232 (serial) interface with
9-pole SubD connector
(Using a USB-RS 232 interface convertor
or a serial interface card could cause
communication problems with the
safety monitoring module)
Software requirements:
• Operating system: Microsoft® Windows
95/98/ME/NT/2000/XP/Vista®
C
Ordering details
Download cable: ASM-DC1
Interface cable with
two RJ 45 connectors,
Length: 0.10 m
Configuration cable: ASM-KC1
Interface cable with one RJ 45
and SUBD 9 connector,
Length: 1.2 m
System components
Download cable ASM-DC1
Configuration cable ASM-KC1
|
|