| | | .-o ® SCHALTBAU | | |
| | | | | |
| | | |
| | | |
| | | Power contactors for AC and DC, Series CT | | |
| | | |
| | | Owing to a new blowout technology, CT Series contactors can be used in almost any AC or DC railway network, even in countries where the normal tolerances are exceeded. The single pole contactor ensures low-wear and reliable switching of both extremely low and very high loads. | | |
| | | Double and triple pole styles are being developed. Especially robust and environmentally friendly materials, from plastics featuring low smoke and low content of toxic gases up to cadmium-free contact tips, are used for the CT1000. It has been tested and approved by independent laboratories. | | |
| | | |
| | | |
| | | Features | | Ordering code | | |
| | | |
| | | |
| | | • Compact, rugged design • 2 breaking capacity levels, 4 current ratings • Double-break contacts, (normally open) • 1, 2, and 3 pole versions • Easy maintenance: • Easy inspection and replacement of main contact tips • Easy replacement of arc chute • Drive system with coil tolerance according to railway standards, no economy circuit required! • Functional insulation for main circuit • Basic insulation between main circuit and protective earth • Reinforced insulation between main circuit and control circuit / auxiliary circuit and protective earth | | |
| | | Example: CT1130/04 H 110ET-00 | | |
| | | |
| | | Series CT11 CT12 CT13 | | |
| | | 1 pole NO contactor 2 pole NO contactor 3 pole NO contactor | | |
| | | |
| | | |
| | | Nominal voltage - 15 Un = 1,500 V 30 Un = 3,000 V Conv. thermal current | | |
| | | |
| | | | | | | | | | | 02 | Ith = | 200 A*1 | | | | 04 | Ith = | 400 A | | | | 08 | Ith = | 800 A*2 | | | | 14 | Ith = | 1,400 A*1 | | | | | | | | | | |
| | | |
| | | |
| | | Mounting position - H Horizontal (lock bar yellow) V Vertical (lock bar red) | | |
| | | |
| | | Coil voltage 24 / 36 / 72 / 110 V DC Coil tolerance E -30 % ... +25 % | | |
| | | Applications | | |
| | | |
| | | • Main contactor for: • traction motors • converters • inverters for auxiliary equipment • Contactor for: • field circuits of motors • conventional resistor based traction units (retrofit) • starters and compressor motors • Power switch for heating circuits • Contactor for a host of industrial applications | | |
| | | |
| | | Coil suppression - T Suppressor diode Auxiliary switches, number and type | | |
| | | |
| | | 1x S870*3 (a1)
| | |
| | | 00 | | |
| | | |
| | | |
| | | 1x S870*3 (b0)
| | M3 screw-type terminals | | |
| | | |
| | | |
| | | 2x S826 a L*4 1x S870*3 (a1) | | |
| | | 01 | | |
| | | |
| | | |
| | | 1x S870*3 (b0)
| | Flat tabs 6.3 x 0.8 | | |
| | | |
| | | 2x S826 a L*4 4x S826 a L*4 } M3 screw-type terminals 4x S826 a L*4 } Flat tabs 6.3 x 0.8 | | |
| | | |
| | | 03 04 | | |
| | | |
| | | |
| | | *1 Series planned *2 Series in development | | *3 See also catalogue D70 *4 See also catalogue D26 | | |
| | | Standards | | |
| | | |
| | | |
| | | Presented in this catalogue are only stock items which can be supplied in short delivery time. Special variant If you need a special variant of the contactor, please do not hesitate to contact us. Maybe the type of contactor you are looking for is among our many special designs. If not, we can also supply customized designs. In this case, however, minimum order quantities apply. | | |
| | | • IEC 60077: Railway applications -Electric equipment for rolling stock • EN 50124-1: Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |