Flyer AC Vacuum Circuit Breaker CVB15, CVB25 - Schaltbau - #1

/ 1


catalogue search
Flyer AC Vacuum Circuit Breaker CVB15, CVB25 - Schaltbau
P. 01
Page:
Flyer AC Vacuum Circuit Breaker CVB15, CVB25 - Schaltbau


See other catalogues for Schaltbau

Text version of the page
Connect - Contact - Control NEW M12 M12 M12 430 940 280 L1 592.5 L2 L3 870 320 6x Ø14 270 L4 200 P R O D U C T I N F O R M A T I O N Schaltbau GmbH Hollerithstrasse 5 81829 Munich Germany Phone +49 89 93005-0 Fax +49 89 93005-350 e-mail contact@schaltbau.de Internet www.schaltbau.com We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.com. S1853/0809/0.5 Printed in Germany by Schaltbau GmbH Issued January 2009 Dimension diagram Specifications Length Series CVB15 CVB25 L1 452 527 L2 347 422 L3 483 558 L4 748 823 Dimensions in mm The CVB Series vacuum circuit breaker is the main electrical switch and protection device of AC locomotives and electric multiple units. Mode of operation: The energy required to switch on the CVB is stored by a spring. It takes only a small pulse energy to unlock the main spring release latch and set free the stored energy. As soon as the supply voltage is applied, the spring gets recharged in less than 10 s. When no control voltage is being applied, the vacuum circuit breaker is in switched off position and the spring remains charged and ready for the next switching operation. Features: ƒÜ Electrically driven vacuum circuit breaker ƒÜ No secondary supply energy like pressurized air required ƒÜ Versions for 15 kV and 25 kV to UIC 550 available ƒÜ Maintenance free: 200,000 operating cycles ƒÜ Following the fail safe principle Application: ƒÜ AC main switch in electric locomotives and EMUs Standards: ƒÜ IEC 60077-4, EN 50124-1, IEC 60694, EN 50155, EN 50121-3-2 CVB15, CVB25 Switchgear for Traction AC Vacuum Circuit Breaker Nominal voltage UN 15 kV AC, 16 Hz OV4 / PD4 25 kV AC, 50/60 Hz OV4 / PD4 Rated operating voltage Ue 17.5 kV AC 30 kV AC Rated operating current Ie 750 A 450 A Short circuit breaking capacity 25 kA 20 kA Utilization category C3 Control voltage Ucontrol 24 / 110 V DC* Operating temperature range - 40°C ... + 70°C Ordering code: Example: CVB15-X-110E-00 Series CVB AC vacuum circuit breaker Nominal voltage 15 / 25 15 kV AC, 16 Hz / 25 kV AC, 50/60 Hz BTE terminal X / R / L none / right / left Control voltage 24 / 110* 24 / 110 V DC Tolerance E -30 % … +25 % Aux. contacts, type and number of 00 10x S826 a L, SPDT * others on request

pageCatalog pdf di En 2012-06-22-01