| | | High-voltage fuses | | AC vacuum circuit breaker | | |
| | | |
| | | |
| | | For the protection ofhigh-voltage switchgear Schaltbau offers a comprehensive range of high-voltage fuses and fuse holders. F-HS Series fuses are main fuses disigned for nominal currents of 7.5 A up to 125 A, whereas F-VS Series fuses are distribution fuses designed for nominalcurrents of3Aupto16A. | | CVB Series vacuum circuit breakers are used as main switches on electric locomotivesand multiple units.Thereareversionsfor 15 kVand 25 kVin accordance with UIC 550. Mode of operation: As soon as the control voltage is applied, the energy stored in a spring is set free to trigger the switching operation. After that the spring is recharged. Thevacuum circuit breaker is in switched off position when no control voltage is being applied, and the spring remains charged and ready for the next switching operation. | | |
| | | |
| | | |
| | | Features | | |
| | | |
| | | Safecut-offofshortcircuits Also available for operating voltages of 5 kV DC Suitableforall UlCvoltages All fuses are approved bythe European railwayauthorities Suitable fuse holders approved for railway useareavailable | | Long-lasting vacuum tube. Minimum wearand long, trouble-freeservicelife Spring actuator: Function guaranteed even when battery is low Maintenance-free: 200,000 operating cycles with no need to adjustthe main contacts, no maintenance ofthe pneumatic Operation without second source of energy, e.g. pneumatic Fail-Safe: Safe switching offin case offailure | | |
| | | |
| | | |
| | | ( Catalogue F185.en ) | | ( Catalogue C30.en ) | | |
| | | |
| | | Specifications | | |
| | | |
| | | | CVB15 | 15kVAC,162/3 17,5kVAC 750A 25kA | | |
| | | 25kVAC,50...60Hz 30kVAC 450A 20kA | | NominalvoltageUn Rated operating voltage Ue Rateoperating current le Short-circuit breaking capacity Utilization category Pollution degree Overvoltage category Mechanical endurance Temperature range Standards | | |
| | | I.OkVAC/I.OkVDC 1.5kVAC/1.5kVDC 3.0kVAC/3.0kVDC 5.0kVDC | | |
| | | Nominal voltage | | |
| | | |
| | | |
| | | Nominal currents MainfusesF-HS Distribution fuses F-VS Fuse sizes MainfusesF-HS Distribution fuses F-VS Fuse holders forfusesizes MainfusesF-HS | | |
| | | |
| | | 7.5...125A 2...16A | | |
| | | C3 PD4 OV4 >200,000cycles -40°C...+70°C IEC 60077-4, EN 50124-1, EN 60694, EN 50155, EN 50121-3-2 | | |
| | | |
| | | 1...8 1,2 | | |
| | | |
| | | 1...8 1,2 | | |
| | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |