Series IA008, IA108, IA109, IA114, 242,ZH254,ZH44
Cam controllers
High-voltage heaters Air and water heaters, tubular heaters, radiators
Development and manufacture ofheaters for rail vehicles have a tradition for decades with Schaltbau.
Schaltbau tubular elements for air and water heaters as well as electric reheating radiators are the backbone ofthe air conditioning system and supply ofwarm water in rail vehicles all over Europe.
To meet various requirements Schaltbau developed a great variety of products - its standard product line.
Cam controllers are mainly used in driver's cabs oflight rail vehicles such as trams.The rugged cam controllers are ofopen design.The switching sequence is implemented by corresponding cam plates to customer requirements.
Operating handles, knobs and hand wheels are available for actuation.
Features
Open design with easily accessible contacts
Switching elements can be replaced individually
Single or double-row arrangement with snap-action switches S800 or S826
Rugged design
Customer-specific implementation of switching sequence by variation of the cam plates
SuitableforallUICvoltages
Insulation is achieved without additional insulators. So touching of heating elements in compact heaters will not damage them.
Noncorrosiveairheatersmadeofchromenickel steel (INOX)
Cooling fins or strips supplied on request
We can supply complete heater groups or heating devices to suit your particular requirements
( Catalogue F195.en )
Specifications
I IA008... IA114, ZHx81,ZH242, ZH254, ZH449, ;
S073
S074
S800,S826 Screws,flattabs
Rating, dimensions,type
Surface
Nominal voltage Electricstrength Mechanical endurance Temperature range Standards
In accordance with customerspecifications
Air heater: Chrome nickel steel (INOX) Water heater: Chrome nickel steel (INOX)
3kVDC
8kVDC,cold
>100,000hours
-40°C...+85°C
IEC61373
Termination ^fl
TemperaturerangJ
Standards
14,single-row
28,double-row
400 V PD3 OV3 10A >300,000cycles -20°C...+70°C IEC60077,VDE0660