| | | Fire Retardant Tapes Scapa Fire Retardant tapes function as a fire barrier to meet more demanding fire propagation and fire survival requirements. These tapes are based on a finelywoven glass substrate, which has intrinsic fire retardant properties, and the surface coating also gives weave stability. All ofthese tapes are free from halogens and sulphur. The high tensile strengths give the additional benefit of excellent binding properties. There is a semi-conducting version available to complementthe rest ofthe insulative range. | | |
| | | |
| | | | | | | | | | | | | | CODE | CABLE TYPE/APPLICATION | TENSILE STRENGTH (N/cm) | WEIGHT (g/m2) | SUBSTRATE | THICKNESS (mm) | | | | FR14/103 | Fire retardant, fire barrier | >200 | 140 | Woven glass | 0.10 | | | | FR21/103 | Fire retardant, fire barrier | >200 | 130 | Woven glass | 0.10 | | | | FR22/103 | Fire retardant, fire barrier | >200 | 140 | Woven glass | 0.11 | | | | FR22/109 | Fire retardant, fire barrier | >300 | 240 | Woven glass | 0.20 | | | | FR4019/205 | Bedding, binding, identification and protection | >8o | 240 | Polyesterviscose stitch bonded fabric | 0.55 | | | | FR62/103 | Fire barrier and electrical core screen | >200 | 125 | Woven glass | 0.11 | | | | SFR10/103 | Superior fire retardant | >200 | 140 | Woven glass | 0.12 | | | | | | | | | | | | | |
| | | |
| | | Fire Retardant Tapes - Key Features & Benefits • Acts as a barrier between the flame and the combustible core/insulation within the cable. • Retains the integrity of the cable during and after exposure to fire. • Extends the fire-survival time ofthe cable and its functions. • High tensile strength aids bonding and prevents bird-caging. • Used in cables designed to meet IEC60332-3 CategoryAand IEC331. • Available in widths, inside and outside diameters, and lengths to suit the cable manufacturers individual requirements. | | |
| | | |
| | | The information supplied is accurate to the best of Scapa's knowledge and is based upon all current data available to it. Properties quoted are typical and do not therefore constitute a specification. Customers must complete their own assessment ofthe product for its intended application under their own conditions. Our technical advice is to be regarded as an expression of opinion only and although such advice is given in good faith, it shall not, in any circumstances, be regarded as the basis of or as being a representation or statement of fact. This applies also where propriety or protective rights of third parties are involved. Any liability arising in respect of our products will be strictly limited to the value of those products charged to the customer and shall not extend to any consequential loss whatsoever and howsoever arising. Freedom from Patent Rights must not be assumed. This document does not form part ofany contract with a customer. | | |
| | | |
| | | | | |
| | | |
| | | | | | | | | | | | | |