サーボモータ型番の見方
SERVO AMPLIFIER
MC
System error
50/60Hz
100V AC
MC
CN1
SG
SG
F-PC
F-PC
R-PC
R-PC
SG
+5
+5 +5
+5
SG
SG
SG
SERVO MOTOR
MA
MB
CN2
NOTE 4)
NOTE 2)
Blue(Black)
Red(White)
Green(Yellow)
RY1
Orange
Orange
Encoder
90V
(24V)
CONT-COM1
CONT1
DC5V〜24V
CONT2
CONT3
CONT4
OUT-COM4
OUT5 12
OUT4 11
OUT3 10
OUT2 8
OUT1 7
DC12V〜24V
26
25
C
C
B 24
B 23
22
21
A
A
User unit
13
NOTE 3)
NOTE 5)
NOTE 8)
NOTE 6)
NOTE 6)
NOTE 2)
SH SH
SH
CN4
CN3
DC5V,
5
4
3
2
1
M
Output COMMON
OUT-COM3 9
3
2
1
ALM1
ALM2
ALM4
NFB
SG
16
17
18
19
20
1
2
3
5
6
4
15 SG
SG
CONT-COM2
SH
A
A
B
B
C
C
-DC
NOTE 9)
+DC
MC
NOTE 9)
24V DC
-DC
+DC
NOTE 7)
140V DC
-DC
24V DC
+DC
-DC
+DC
Shell:10314-52A0-008
Plug:10114-3000PE
Plug:10126-3000PE
Shell:10326-52A0-008
Housing:DK-3100S-03R
Contact: DK-3RECLLP1-100 Contact: DK-3RECLLP1-100
Housing:DK-3100S-05R
power supply
Main circuit
Control circuit power supply
Power
Supply
Unit
Start ready Start ready
ON OFF
Emergency
stop
Line driver
HD26C31 Corresponding
Line driver
HD26C31
Corresponding
Line driver
HD26C31
Corresponding
pulse
pulse
Forward
revolution
Backward
revolution
Position command pulse input
Encoder division signal output
General purpose output
General-purpose input
Deviation clear
propotional
Servo ON
Velocity loop
control
Alarm Reset
Holding brake
(for the type with a brake only)
Output COMMON
Deviation
Start ready
complete output
zero output
code
Alarm
output
Note 1) For the parts marked ,use a twisted
pair shielded cable.
Note 2) For a cable clamp method, can do shield
connection by clamping a drain line.
Note 3) Connection of the motor side is different
by specifications of a motor.
Note 4) For how to wire the encoder
connector,refer to the encoder wiring
diagram.
Note 5) Refer to the following figure when
connecting the command pulse input to
the open collector output.
Note 6) Your are required to prepare the power.
Either of the inputs can be selected.
Note 7) We recommend that a UL-approved earth
leakage breaker be used that complies
with IEC or EN standard.
Note 8) Make sure to connect the differential
input SG. If not connected,malfunction or
breakage may result due to noise.
Note 9) A power supply for control power please
use a power supply that insulated double
or reinforced from a primary power
supply of 100V or 200V.
External Wiring Diagram
SERVO AMPLIFIER
MC
System error
50/60Hz
100V AC
MC
CN1
ON OFF
MC
Emergency
stop
SERVO MOTOR
MA
MB
CN2
NOTE 2)
RY1
Orange
Orange
Encoder
90V
(24V)
NOTE 6)
CONT-COM1
CONT1
DC5V〜24V
1
2
3 CONT2
5 CONT3
6 CONT4
OUT-COM4
OUT5 12
OUT4 11
OUT3 10
OUT2 8
OUT1 7
DC12V〜24V
26
25
B 24
B 23
22
21
A
A
User unit
13
NOTE 3)
NOTE 5)
NOTE 6)
NOTE 2)
SH SH
SH
CN4
CN3
DC5V,
5
4
3
2
1
+DC
-DC
Control circuit power supply
24V DC
NOTE 7)
4
M
OUT-COM3 9
3
2
1
NFB
-DC
+DC
NOTE 7)
CONT-COM2
SH
A
A
B
B
15
14
SG
SG
/T-REF
V-REF
SG
-
+
VCMD/TCMD
SG
20 SG
SG
-DC
+DC
-DC
+DC
24V DC
140V DC
NOTE 4)
Contact :DK-3RECLLP1-100
Housing:DK-3100S-05R Housing:DK-3100S-03R
Contact :DK-3RECLLP1-100
Plug:10114-3000PE
Shell:10314-52A0-008
Plug:10126-3000PE
Shell:10326-52A0-008
C
C
C
C
power supply
Main circuit
Power
Supply
Unit
Start ready Start ready
General-purpose input
General-purpose output
Velocity command/
Torque command input
Alarm Reset RST
Servo ON SON
propotional
Deviation clear CLR
control PCON
Velocity loop
Line driver
HD26C31 Corresponding
Blue(Black)
Red(White)
Green(Yellow)
Encoder division signal output
Holding brake
(for the type with a brake only)
Output COMMON
ALM1
ALM2
ALM4
Output COMMON
Start ready
complete output
code
Alarm
output
Low speed
output
Velocity command/Torque command Type
Position command Type
15
18
16
20
Forward
revolution
pulse
Backward
revolution
pulse
Note 1) For the parts marked ,use a twisted
pair shielded cable.
Note 2) For a cable clamp method, can do shield
connection by clamping a drain line.
Note 3) Connection of the motor side is different
by specifications of a motor.
Note 4) For how to wire the encoder
connector,refer to the encoder wiring
diagram.
Note 5) Your are required to prepare the power.
Either of the inputs can be selected.
Note 6) We recommend that a UL-approved earth
leakage breaker be used that complies
with IEC or EN standard.
Note 7) A power supply for control power please
use a power supply that insulated double
or reinforced from a primary power
supply of 100V or 200V.
|
|