You may also be interested in
Converter, AC servo-drive, DC servo-drive, Centrifugal fan, On-line UPS
Text version of the page
3
Easy Set-up for Optimal Operation
Auto-Tuning
A new auto-tuning algorithm improves system
response by providing functions such as inertia
identification, 5 auto-tuning modes, 30 levels of
response, and parameter setting auto-save.
Tuning start
Velocity command
value
Detected velocity value
Test Function (JOG)
On-board JOG operation function is available for
testing motor and amplifier connection without the
need to connect to host device.
5-digit LED Display, Built-in Operator
Parameter setting, monitoring and alarm
tracing can be easily done using the built-in operator.
Capable of JOG operation
without connecting
to host device
Power Supply Harmonic Suppression
Equipped with DC reactor connection terminals as
standard feature for supressing power supply
harmonics.
DL1
DL2
DC reactor
iOptionj
Built-in Dynamic Brake
A built-in dynamic brake provides emergency stop
capability. The six kinds of motion sequences for the
dynamic brake can be selected by parameter setting.
Rotation speed
(min-1)
Time(s)
Controlled
state Dynamic braking state
Built-in Regeneration Resistor
A built-in regeneration resistor can be used to absorb
regenerative energy generated during motor
deceleration. External regeneration resistors can be
added if internal regeneration capacity is insufficient.
Built-in Regeneration Resistor
External regenerative
resistor (option)
|
|