24 Standard Specifications Model Number Nomencalture System Configuration Features and Functions Optional Equipment Dimensions External Wiring Diagram Setup Software Amp,capacity 50A DL1 DL2 RB1 RB2 P RB4 - + Amp,capacity 100AC150A Amp,capacity 300A DL1 DL2 RB1 P RB2 - + RB2 CNB DL1 - P DL2 RB1 + Note 2) Note 3) Note 4) Note 2) Note 3) Note 4) Terminal block Terminal block External regenerative resistor External regenerative resistor MC MC MC Single-phase (200V) 50^60Hz 200 to 230V Single-phase AC Powe Note 10) User Unit Operation Prep. ON Operation Prep. OFF System Error Emergency Stop 3-phase (200V) Amp,capacity 50A User Unit 3-phase AC power Note 10) System Error Emergency Stop Operation Prep. ON Operation Prep. OFF External power source for output (+24V) NC ready (NCRDY) In-position (INPS) Positioning complete (PFIN) While operation (MOVE) External operation effective (EXT) Homing complete (ZFIN) Holding brake excitation timing output (HBON) Error output (Err) Power ON ready (A-RDY) Slow down before Home (SDN) External power source for input (+24G) Common for output external power (24G) 1 step feeding (+1step) 1 step feeding (-1step) Interruption start (I_RUN) MFIN (MFIN) External data setting (E_STR) Output selection 3 (SEL3) Over travel (-0T) Over travel (+0T) Manual feeding (+JOG) Manual feeding (-JOG) Over ride (OVRID)/Manual high speed (RAP) Homing start (ZRT) External Error (EXT_E) Alarm reset (ARST) Servo ON (S-ON) Cancel (CACL) Output selection 1 (SEL1) Output selection 2 (SEL2) Start (RUN) { | { | { | Point specification 200 to 230V 50/60Hz Note 11) Note 2) Note 3) Note 4) SERVO AMPLIFIER Regenerative resistor Shell : 10320-52A0-008 Plug : 10120-3000PE, SERVO MOTOR Orange (for the type with Holding brake a brake only) (Yellow) Orange (Yellow) Note 6) White Red Green (Green/Yellow) Black Encoder Encoder connector Note 5) Note 7) Note 2) Note 8) General-purpose output Note 8) MC MC T R S t r W V U CN2 SH SH RY1 90V (24V) 12 7 3 4 6 5 8 9 10 11 14 12 13 15 16 24 17 18 26 25 19 27 20 21 22 23 28 29 30 31 33 32 34 35 36 39 37 38 40 41 46 42 43 45 44 47 48 49 50 OUT(1) OUT(4) OUT(3) OUT(2) OUT(5) OUT(6) OUT(7) OUT(8) IN(16) IN(1) IN(2) IN(8) IN(4) IN(64) IN(32) IN(128) CN1 MC Plug :10150-3000PE Shell :10350-52A0-008 Built-in regenerative resistor Note 1) For the parts marked , use a shielded cable. Note 2) AMP. capacity 50A When using an external regenerative resistor, connect it between RB1 and 2. If RB1 and 2are connected to the internal amplifier's resistor, or if a shorting bar is connected between RB1and 4, first disconnect them. AMP. capacity 100A,150A When using internal regenerative resistor, connect short-circuit bar between RB1 and RB4 terminals. When using external regenerative resistor, connect it between RB1 and RB2 terminalsafter removing short-circuit bar between RB1 and RB4 terminals. AMP. capacity 300A Connect external regenerative resistor between RB1 and RB2 terminals. Note 3) The DL1 and DL2 terminals are for connecting a DC reactor. If a DC reactor is not used, short the DL1 and DL2 terminals using the short bar supplied. Note 4) The terminal and the P terminal are for maintenance Note 5) Refer to the Instruction Manual for instructions on theshielding process. Note 6) The motor-side connection depends on the motor specification. The red, white, black green and orange markings are for use with lead type motor power line and brake line. Refer to the motor specifications for cannon plug type connections. Note 7) Refer to the encoder connection diagram regarding the encoder connector wiring. Note 8) Power should be supplied by the user. Either of the inputs can be selected. Note 9) R,S,T,t,r, ,P,DL1,DL2,RB1,RB2, RB4 (100A, 150A only), U,V,W are high-voltage circuits, all other lines are low-voltage. Ensure sufficient distance between the high- and low-voltage circuits. Note 10) It is recommended to use a ground fault interrupter conforming to the UL, IEC and EN standards. Note 11) Do not wire the S phase for a single-phase power amplifier. 50A : CNA 100 to 300A : Terminalblock 50A : CNC 100 to 300A : Terminalblock Servo Amplifer built-in positioning function model Main Power : 200V AC^Control Power : 200V AC

pageCatalog pdf di En 2012-02-07-15