AC SERVO - SANMOTION R AC100V 30-200W / AC200V 30W-1kW - SANYO DENKI EUROPE - #23 |
|
You may also be interested in
PLC, UPS, AC servo-drive, Controller, DC servo-motor
Text version of the page
22
Standard
Specifications
Model Number
Nomencalture
System
Configuration
Features and
Functions
Optional
Equipment
Dimensions External Wiring
Diagram
Setup Software
Single-Axis Servo Amplifier built-in positioning function serial interface model
3-phase(200V AC)
MC
MC
MC
User Unit
Note 10)
1-phase(100V AC) 1-phase(200V AC)
Note10)
MC
MC
MC
1-phase
AC power
100 to 115V
50/60Hz
3-phase
AC power
200 to 230V
50/60Hz
User Unit
System Error
Emergency
Stop
Operation Prep.
ON
Operation Prep.
OFF
Operation Prep.
ON
System Error
Emergency
Stop
Operation Prep.
OFF
Operation Prep.
ON
System Error
Emergency
Stop
Operation Prep.
OFF
General-purpose output
General-purpose input
SH
SH
OUT-COM
6
CONT3
5 CONT4
4
MC
DC24V
Note10)
MC
MC
CONT1
CONT2
2
3
1
OUT1 7
OUT2 8
OUT-PWR 9
P
RB2
DL1
DL2
RB1
CNA
CN1
T
S
t
r
R
+
CN2 Encoder connector
SH
Plug : 10120-3000PE,
Shell : 10320-52A0-008
SH
V
U
Regenerative
resistor
CNC
W
User Unit
CNB
90V
(24V)
RY1
DC24V
A/A'
GND
B/B'
GND
8
SG
4
5
CN4
8
A/A'
B/B' 4
5
CN3
組み合わせ
CONT-COM
Plug: TM21P-88P or equivalent
Combination
RS-485
TRANCEIVER
SH
SH
SW2
1/4W 120ル
(3M)
(Hirose)
Plug: TM21P-88P or equivalent
Combination
(Hirose)
SERVO MOTOR
Plug kit: MUF-PK10K-X or equivalent
Combination
(J.S.T.Mfg.CO.,LTD)
Note 11)
Note 2)
Note 3)
Note 4)
SERVO AMPLIFIER
1-phase
AC power
200 to 230V
50/60Hz
Holding brake
(for the type with
a brake only)
Orange
(Yellow)
Orange
(Yellow)
Note 6)
Note 5)
Note 8)
Note 1)
Note 1)
Note 8)
Note 7)
White
Red
Green
(Green/Yellow)
Black
Encoder
Note 1) For the parts marked , use a shielded cable.
Note 2) Connect regenerative resistor between RB1 and RB2 terminals.
Note 3) The DL1 terminal and DL2 terminal are terminals to connect to
the DC reactor. When a DC reactor is not used, short-circuit between
DL1 and DL2 terminals with the supplied short-circuit bar.
Note 4) The terminal and the P terminal are for maintenance
Note 5) Refer to the Instruction Manual for instructions on the shielding
process.
Note 6) The motor-side connection depends on the motor specification.
The red, white, black green and orange markings are
for use with lead type motor power line and brake line.
Refer to the motor specifications for cannon plug type connections.
Note 7) Refer to the encoder connection diagram regarding
the encoder connector wiring.
Note 8) Power should be supplied by the user.
Either of the inputs can be selected.
Note 9) R,S,T,t,r, ,P,DL1,DL2,RB1,RB2,U,V,W are high-voltage circuits,
all other lines are low-voltage. Ensure sufficient
distance between the high- and low-voltage circuits.
Note 10) It is recommended to use a ground fault interrupter conforming
to the UL, IEC and EN standards.
Note 11) Do not wire the S phase for a single-phase power amplifier.
○
○
|
|