21 External Wiring Diagram Single-Axis Servo Amplifier built-in positioning function model MC MC 3-phase(200V AC) 1-phase(200V AC) MC Operation Prep. System Error Emergency Stop ON Operation Prep. OFF | { User Unit 1-phase(100V AC) Note10j MC User Unit MC MC 1-phase AC power 100 to 115V 50^60Hz Operation Prep. System Error Emergency Stop ON Operation Prep. OFF Note 1) For the parts marked , use a shielded cable. Note 2) Connect regenerative resistor between RB1 and RB2 terminals. When using external regenerative resistor, terminals. When using external regenerative resistor, connect it between RB1 and RB2 terminals after removing the wiring of built-in regenerative resistor. Note 3) The DL1 and DL2 terminals are for connecting a DC reactor. If a DC reactor is not used, short the DL1 and DL2 terminals using the short bar supplied. Note 4) The terminal and the P terminal are for maintenance Note 5) Refer to the Instruction Manual for instructions on the shielding process. Note 6) The motor-side connection depends on the motor specification. The red, white, black green and orange markings are for use with lead type motor power line and brake line. Refer to the motor specifications for cannon plug type connections. Note 7) Refer to the encoder connection diagram regarding the encoder connector wiring. Note 8) Power should be supplied by the user. Either of the inputs can be selected. Note 9) R,S,T,t,r, ,P,DL1,DL2,RB1,RB2,U,V,W are high-voltage circuits, all other lines are low-voltage. Ensure sufficient distance between the high- and low-voltage circuits. Note 10) It is recommended to use a ground fault interrupter conforming to the UL, IEC and EN standards. Note 11) Do not wire the S phase for a single-phase power amplifier. User Unit 3-phase AC power Note 10) System Error Emergency Stop Operation Prep. ON Operation Prep. OFF External power source for output (+24V) NC ready (NCRDY) In-position (INPS) Positioning complete (PFIN) While operation (MOVE) External operation effective (EXT) Homing complete (ZFIN) Holding brake excitation timing output (HBON) Error output (Err) Power ON ready (A-RDY) Slow down before Home (SDN) External power source for input (+24G) Common for output external power (24G) 1 step feeding (+1step) 1 step feeding (-1step) Interruption start (I_RUN) MFIN (MFIN) External data setting (E_STR) Output selection 3 (SEL3) Over travel (-0T) Over travel (+0T) Manual feeding (+JOG) Manual feeding (-JOG) Over ride (OVRID)/Manual high speed (RAP) Homing start (ZRT) External Error (EXT_E) Alarm reset (ARST) Servo ON (S-ON) Cancel (CACL) Output selection 1 (SEL1) Output selection 2 (SEL2) Start (RUN) { | { | { | Point specification 200 to 230V 50/60Hz MC CNA T Note 11) R S t r MC MC RB2 CNB DL1 P DL2 RB1 Note 2) Note 3) Note 4) SERVO AMPLIFIER Regenerative resistor Shell : 10320-52A0-008 W V CNC Plug : 10120-3000PE U CN2 SH SH SERVO MOTOR RY1 90V (24V) Orange (for the type with Holding brake a brake only) (Yellow) Orange (Yellow) Note 6) White Red Green (Green/Yellow) Black Encoder Encoder connector Note 5) Note 7) CN1 Note 2) Note 8) 12 7 3 4 6 5 8 9 10 11 14 12 13 15 16 24 17 18 26 25 19 27 20 21 22 23 28 29 30 31 33 32 34 35 36 39 37 38 40 41 46 42 43 45 44 47 48 49 50 OUT(1) OUT(4) OUT(3) OUT(2) OUT(5) OUT(6) OUT(7) OUT(8) General-purpose output Note 8) IN(16) IN(1) IN(2) IN(8) IN(4) IN(64) IN(32) IN(128) Shell : 10350-52A0-008 Plug : 10150-3000PE Note 10) 1-phase AC power 200 to 230V 50/60Hz Note 1) For the parts marked , use a shielded cable. Note 2) Connect regenerative resistor between RB1 and RB2 terminals. When using external regenerative resistor, terminals. When using external regenerative resistor, connect it between RB1 and RB2 terminals after removing the wiring of built-in regenerative resistor. Note 3) The DL1 and DL2 terminals are for connecting a DC reactor. If a DC reactor is not used, short the DL1 and DL2 terminals using the short bar supplied. Note 4) The terminal and the P terminal are for maintenance Note 5) Refer to the Instruction Manual for instructions on the shielding process. Note 6) The motor-side connection depends on the motor specification. The red, white, black green and orange markings are for use with lead type motor power line and brake line. Refer to the motor specifications for cannon plug type connections. Note 7) Refer to the encoder connection diagram regarding the encoder connector wiring. Note 8) Power should be supplied by the user. Either of the inputs can be selected. Note 9) R,S,T,t,r, ,P,DL1,DL2,RB1,RB2,U,V,W are high-voltage circuits, all other lines are low-voltage. Ensure sufficient distance between the high- and low-voltage circuits. Note 10) It is recommended to use a ground fault interrupter conforming to the UL, IEC and EN standards. Note 11) Do not wire the S phase for a single-phase power amplifier.

pageCatalog pdf di En 2012-02-07-16