AC COOLING FAN - SANYO DENKI EUROPE - #6

/ 52


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
P. 41
P. 42
P. 43
P. 44
P. 45
P. 46
P. 47
P. 48
P. 49
P. 50


See other catalogues for SANYO DENKI EUROPE

Text version of the page
5 AC San Ace 1. UL ratings  (USA) Underwriters Laboratories Inc. was established by the American Union of Fire Insurance Underwriters. The purpose of UL is to ensure safety of machines, equipment, and materials and protect human lives and property from fire and other accidents. To that end, UL has conducted numerous tests and extensive research and, as a result, set up UL ratings. Any seller of products in any of the majority of the states of the USA must produce their products according to the UL ratings, have them pass UL-specified safety inspections, and have them listed in UL's registration book. Therefore, to export and sell any product in the United States, one must in most cases apply for UL-listing. Additionally, UL is accredited by The Standards Council of Canada (SCC) as both a Certification Organization (CO) and a Testing Organization (TO) and is officially recognized in all provinces and territories throughout Canada. Accordingly, our products can be tested by UL for compliance with Canadian safety standards. Certified products are entitled to display the C-UL Mark, which authorizes their use and sale in Canada. If products are deemed to be compliant with both U.S. and Canadian standards, then both the UL Mark and C-UL Mark can be displayed or a combination U.S. and Canadian mark (bottom left). Our products are certified as satisfying all UL507 requirements. Safety standards Description of safety standards Safety standard list ■Plug Code 489-008-L10 489-008-L21 489-008-L35 489-016-L10 489-016-L21 489-006-L10 489-006-L21 489-006-L35 489-037-L10 489-037-L21 489-037-L35 489-1618-L10 489-1618-L21 489-1618-L28 UL CSA TワV CE UL・CSA・TワV and CE acquired Model.No Applicable model 80ラ80ラ42mm 80ラ80ラ42mm 80ラ80ラ42mm 120ラ120ラ25mm 92ラ92ラ25mm  80ラ80ラ25mm 80ラ80ラ38mm 120ラ120ラ25mm 92ラ92ラ25mm  80ラ80ラ25mm 80ラ80ラ38mm 120ラ120ラ38mm 120ラ120ラ38mm 120ラ120ラ38mm 120ラ120ラ38mm 120ラ120ラ38mm 120ラ120ラ38mm 160ラ160ラ51mm 160ラ160ラ51mm 160ラ160ラ51mm 489-1619-L10 489-1619-L21 489-007-L10 489-007-L21 489-047-L10 489-047-L21 489-084-L10 489-084-L21 489-086-L10 489-086-L21 Model.No UL CSA TワV CE Applicable model 172mmラ51mm 160ラ160ラ51mm 172mmラ51mm 160ラ160ラ51mm 120ラ120ラ38mm 120ラ120ラ38mm 120ラ120ラ25mm 92ラ92ラ25mm  80ラ80ラ25mm 80ラ80ラ38mm 120ラ120ラ25mm 92ラ92ラ25mm  80ラ80ラ25mm 80ラ80ラ38mm 172mmラ51mm 160ラ160ラ51mm  L-Shaped 172mmラ51mm 160ラ160ラ51mm  L-Shaped 160ラ160ラ51mm Straight 160ラ160ラ51mm Straight The meaning of the specifi cations @Voltage This is the necessary voltage to drive the fan. Single-phase AC100V, AC115V, AC200V and AC230V are also available. AFrequency This is a frequency of alternating current(AC). The frequencies of 50Hz and 60Hz are existing in Japan. Performance of AC fan varies depending on the frequency. BInput The input value during the fan's rated operation without load. CCurrentThe current value during the fan's rated operation without load. DLocked Rotor Current This is a current when rotor of motor that applies rated voltage is locked. ERated Speed The rotating speed during the fan's rated operation without load. FAir Flow The maximum air volume that the fan can output during rated operation (according to the company's dual-chamber device). The volume of air generated by the fan in a given time period. GStatic Pressure The maximum static pressure value that the fan can output during rated operation (according to the company's dual-chamber device). The static pressure is the fan's force to propel air by overcoming the resistance of the device that uses the fan when it propels air. HSPL "SPL" is Sound Pressure Level. The noise level during the fan's rated operation. Please refer to Page 45 for the method used to measure the noise. IOperating Temperature Range The temperature range over which fan operation is guaranteed (Non- condensing) JLife Expectancy The fan's expected operating life when the fan operates continuously at the rated voltage at a temperature of 60「ェC and at relative humidity of 90%. For details, please refer to Page 45. @ A B C D E F G H I J Model No. Voltage Frequency Input Current Locked Rotor Current Rated Speed Air Flow Static Pressure SPL Operating Temperature Life Expectancy [V] [Hz] [W] [A] [A] [min-1] [mウ/min] [CFM] [Pa] [inchHイO] [dB(A)] [℃] [h] 109-180 100 50/60 5/4 0.06/0.05 0.07/0.06 2250/2700 0.27/0.33 9.5/11.7 11.8/18.6 0.047/0.075 24/26 −30 to +70 25,000 109-183 115 0.06/0.05

pageCatalog pdf di En 2012-02-07-14