5
AC San Ace
1. UL ratings
(USA)
Underwriters Laboratories Inc. was established by the American Union of Fire Insurance Underwriters. The
purpose of UL is to ensure safety of machines, equipment, and materials and protect human lives and property
from fire and other accidents. To that end, UL has conducted numerous tests and extensive research and, as
a result, set up UL ratings. Any seller of products in any of the majority of the states of the USA must produce
their products according to the UL ratings, have them pass UL-specified safety inspections, and have them listed
in UL's registration book. Therefore, to export and sell any product in the United States, one must in most cases
apply for UL-listing.
Additionally, UL is accredited by The Standards Council of Canada (SCC) as both a Certification Organization
(CO) and a Testing Organization (TO) and is officially recognized in all provinces and territories throughout
Canada. Accordingly, our products can be tested by UL for compliance with Canadian safety standards. Certified
products are entitled to display the C-UL Mark, which authorizes their use and sale in Canada. If products are
deemed to be compliant with both U.S. and Canadian standards, then both the UL Mark and C-UL Mark can be
displayed or a combination U.S. and Canadian mark (bottom left).
Our products are certified as satisfying all UL507 requirements.
Safety standards
Description of safety standards
Safety standard list
■Plug Code
489-008-L10
489-008-L21
489-008-L35
489-016-L10
489-016-L21
489-006-L10
489-006-L21
489-006-L35
489-037-L10
489-037-L21
489-037-L35
489-1618-L10
489-1618-L21
489-1618-L28
UL CSA TワV CE
UL・CSA・TワV and CE acquired
Model.No Applicable model
80ラ80ラ42mm
80ラ80ラ42mm
80ラ80ラ42mm
120ラ120ラ25mm 92ラ92ラ25mm
80ラ80ラ25mm 80ラ80ラ38mm
120ラ120ラ25mm 92ラ92ラ25mm
80ラ80ラ25mm 80ラ80ラ38mm
120ラ120ラ38mm
120ラ120ラ38mm
120ラ120ラ38mm
120ラ120ラ38mm
120ラ120ラ38mm
120ラ120ラ38mm
160ラ160ラ51mm
160ラ160ラ51mm
160ラ160ラ51mm
489-1619-L10
489-1619-L21
489-007-L10
489-007-L21
489-047-L10
489-047-L21
489-084-L10
489-084-L21
489-086-L10
489-086-L21
Model.No UL CSA TワV CE Applicable model
172mmラ51mm 160ラ160ラ51mm
172mmラ51mm 160ラ160ラ51mm
120ラ120ラ38mm
120ラ120ラ38mm
120ラ120ラ25mm 92ラ92ラ25mm
80ラ80ラ25mm 80ラ80ラ38mm
120ラ120ラ25mm 92ラ92ラ25mm
80ラ80ラ25mm 80ラ80ラ38mm
172mmラ51mm 160ラ160ラ51mm
L-Shaped
172mmラ51mm 160ラ160ラ51mm
L-Shaped
160ラ160ラ51mm Straight
160ラ160ラ51mm Straight
The meaning of the specifi cations
@Voltage This is the necessary voltage to drive the fan.
Single-phase AC100V, AC115V, AC200V and AC230V are also available.
AFrequency This is a frequency of alternating current(AC). The frequencies of 50Hz and 60Hz are existing in Japan.
Performance of AC fan varies depending on the frequency.
BInput The input value during the fan's rated operation without load.
CCurrentThe current value during the fan's rated operation without load.
DLocked Rotor Current This is a current when rotor of motor that applies rated voltage is locked.
ERated Speed The rotating speed during the fan's rated operation without load.
FAir Flow The maximum air volume that the fan can output during rated operation
(according to the company's dual-chamber device).
The volume of air generated by the fan in a given time period.
GStatic Pressure The maximum static pressure value that the fan can output during rated operation
(according to the company's dual-chamber device).
The static pressure is the fan's force to propel air by overcoming the resistance of the device that uses
the fan when it propels air.
HSPL "SPL" is Sound Pressure Level. The noise level during the fan's rated operation.
Please refer to Page 45 for the method used to measure the noise.
IOperating Temperature Range The temperature range over which fan operation is guaranteed (Non- condensing)
JLife Expectancy The fan's expected operating life when the fan operates continuously at the rated voltage at a
temperature of 60「ェC and at relative humidity of 90%.
For details, please refer to Page 45.
@ A B C D E F G H I J
Model No. Voltage Frequency Input Current Locked Rotor Current Rated Speed Air Flow Static Pressure SPL Operating Temperature Life Expectancy
[V] [Hz] [W] [A] [A] [min-1] [mウ/min] [CFM] [Pa] [inchHイO] [dB(A)] [℃] [h]
109-180 100
50/60 5/4 0.06/0.05
0.07/0.06
2250/2700 0.27/0.33 9.5/11.7 11.8/18.6 0.047/0.075 24/26 −30 to +70 25,000
109-183 115 0.06/0.05
|