3
Constant current circuit
Source voltage : DC24V・operating current : 2A/phase,
2-phase energization(full-step)
JL =[ 0.94x10-4kg・m2(5.14 oz・in2)Use the rubber coupling]
fs: No load maximum starting pulse rate
● SH1421-52 □□
0.1 1 10 100
Pulse rate(kpulse/s)
70
0
60
50
40
30
20
10
Torque(kgf・cm)
Torque(oz・in)
Torque(N・m)
1
2
3
4
5
0
0.1
0.2
0.3
0.4
0.5
0
Pull-out torque at JL
fs
Number of rotations (min-1)
100 1000 2000 3000 5000
■ Pulse rate-torque characteristics
0.1 1 10 100
Pulse rate(kpulse/s)
70
0
60
50
40
30
20
10
Torque(kgf・cm)
Torque(oz・in)
Torque(N・m)
1
2
3
4
5
0
0.1
0.2
0.3
0.4
0.5
0
Pull-out torque at JL
fs
Number of rotations (min-1)
100 1000 2000 3000 5000
● SH1422-52 □□ ● SH1424-52 □□
0.1 1 10 100
Pulse rate(kpulse/s)
70
0
60
50
40
30
20
10
Torque(kgf・cm)
Torque(oz・in)
Torque(N・m)
1
2
3
4
5
0
0.1
0.2
0.3
0.4
0.5
0
Pull-out torque at JL
fs
Number of rotations (min-1)
100 1000 2000 3000 5000
Bipolar winding・Lead wire type
Model Holding torque at 2-phase
energization Rated current Wiring resistance Winding inductance Rotor inertia Mass(Weight)
Single shaft Double shafts [N・m (oz・in)MIN.] A/phase ル /phase mH/phase [ラ10- 4kg・m2 (oz・in2)] [kg(Ibs)]
SH1421-5041 -5011 0.23(32.5) 1 3.3 8.0 0.044(0.24) 0.24(0.53)
SH1421-5241 -5211 0.23(32.5) 2 0.85 2.1 0.044(0.24) 0.24(0.53)
SH1422-5041 -5011 0.34(48.1) 1 4.0 14.0 0.066(0.36) 0.29(0.64)
SH1422-5241 -5211 0.34(48.1) 2 1.05 3.6 0.066(0.36) 0.29(0.64)
SH1424-5041 -5011 0.48(67.9) 1 4.7 15.0 0.089(0.49) 0.38(0.84)
SH1424-5241 -5211 0.48(67.9) 2 1.25 3.75 0.089(0.49) 0.38(0.84)
Constant current circuit
Source voltage : DC24V・operating current : 2A/phase,
2-phase energization(full-step)
JL =[ 0.94x10-4kg・m2(5.14 oz・in2)Use the rubber coupling]
fs: No load maximum starting pulse rate
Constant current circuit
Source voltage : DC24V・operating current : 2A/phase,
2-phase energization(full-step)
JL =[ 0.94x10-4kg・m2(5.14 oz・in2)Use the rubber coupling]
fs: No load maximum starting pulse rate
The data are measured under the drive condition of our company. The drive torque may very depending on the accuracy of customer-side equipment.
Constant current circuit
Source voltage : DC24V・operating current : 2A/phase,
2-phase energization(full-step)
JL =[ 0.94x10-4kg・m2(5.14 oz・in2)Use the rubber coupling]
fs: No load maximum starting pulse rate
● SH1421-50 □□
0.1 1 10 100
fs
Pulse rate(kpulse/s)
0.5
0.4
0.3
0.2
0.1
0
5
4
3
2
1
0
Torque(kgf・cm)
Torque(oz・in)
60
40
20
0
Torque(N・m)
Pull-out torque at JL
Number of rotations (min-1)
100 1000 2000 3000 5000
0.1 1 10 100
fs
Pulse rate(kpulse/s)
0.5
0.4
0.3
0.2
0.1
0
5
4
3
2
1
0
Torque(kgf・cm)
Torque(oz・in)
60
40
20
0
Torque(N・m)
Pull-out torque at JL
Number of rotations (min-1)
100 1000 2000 3000 5000
● SH1422-50 □□ ● SH1424-50 □□
0.1 1 10 100
fs
Pulse rate(kpulse/s)
0.5
0.4
0.3
0.2
0.1
0
5
4
3
2
1
0
Torque(kgf・cm)
Torque(oz・in)
60
40
20
0
Torque(N・m)
Pull-out torque at JL
Number of rotations (min-1)
100 1000 2000 3000 5000
Constant current circuit
Source voltage : DC24V・operating current : 2A/phase,
2-phase energization(full-step)
JL =[ 0.94x10-4kg・m2(5.14 oz・in2)Use the rubber coupling]
fs: No load maximum starting pulse rate
Constant current circuit
Source voltage : DC24V・operating current : 2A/phase,
2-phase energization(full-step)
JL =[ 0.94x10-4kg・m2(5.14 oz・in2)Use the rubber coupling]
fs: No load maximum starting pulse rate
|