Catalog excerpts
COOLING SYSTEMS DC fans with various features, such as high air flow, long life, splash proofing, and oil proofing These fans are detailed separately in the DC
Open the catalog to page 2Technical Material Characteristics Calculation Method and Description ••• P.46
Open the catalog to page 3Domain Diagram AC Fan Air Flow(m 3 /min) Frame Size Conversion table Safety Standard List AC Fan Frame size
Open the catalog to page 4Frame size
Open the catalog to page 5Safety Standard List Plug Code ✓ UL CSA TÜV and CE acquired Model.No Applicable model Applicable model The Meaning of the Specifications Model No. Voltage Frequency Input Current Locked Rotor Current Rated Speed Max. Air Flow SPL Operating Temperature Range Expected Life Locked Rotor Current Rated Speed A Operating Temperature Expected Life This is the necessary voltage to drive the fan. Single-phase AC100V, AC115V, AC200V and AC230V are also available. This is a frequency of alternating current(AC). The frequencies of 50Hz and 60Hz are existing in Japan. Performance of AC fan varies...
Open the catalog to page 6The Canadian Standards Association (CSA) was set up in response to the advice of the Canadian government. In Canada, the law prohibits the use and sale of any product other than those approved under CSA in terms of safety. CSA has set up CSA standards as inspection procedures and other requirements to ensure product safety. Our products are certified as satisfying the CSA standard C22.2 No. 113. In the EU territory, the harmonization of industrial standards and safety standards of different countries is under way. The unified standards are called Harmonized Standards. Each of these...
Open the catalog to page 7General Specifications Material Expected Life Frame: Aluminum, Impeller:Plastics (Flammability: UL94V-1) Refer to specifications (L10: Survival rate: 90% at 60 , rated voltage, and continuously run in a free air state) 50/60Hz 1,500VAC 1minute (between lead conductor and frame) Black, 2pcs 30 to 70 (Non-condensing Voltage of each model 10% Dielectric Strength Lead Wire Storage Temperature Operating Voltage Range Locked Rotor Current Rated Speed A Operating Temperature Expected Life Dimensions Unit : mm 8- 4.3 Mounting Hole 10 Lead Wire AWG26 UL1430 M4 0.7 Earth Ground tap Air Flow Direction...
Open the catalog to page 8Finger guards color Model: 109-139E Surfacetreatment : Nickel-chrome plating (silver) : 109-139H : Cation electropainting (black) Inlet side. Outlet side Resin finger guards Resin filter kits Air Flow - Static Pressure Characteristics
Open the catalog to page 9General Specifications Material Expected Life Frame: Aluminum, Impeller:Plastics (Flammability: UL94V-1) Refer to specifications (L10: Survival rate: 90% at 60 , rated voltage, and continuously run in a free air state) 50/60Hz 1,500VAC 1minute (between lead conductor and frame) Black, 2pcs 30 to 70 (Non-condensing Voltage of each model 10% Dielectric Strength Lead Wire Storage Temperature Operating Voltage Range Locked Rotor Current Rated Speed A Operating Temperature Expected Life Dimensions Unit : mm 8- 4.3 Mounting Hole M4 0.7 Earth Ground tap Air Flow Direction Rotating Direction...
Open the catalog to page 10Finger guards color Model: 109-139E Surfacetreatment : Nickel-chrome plating (silver) : 109-139H : Cation electropainting (black) Inlet side. Outlet side Resin finger guards Resin filter kits Air Flow - Static Pressure Characteristics
Open the catalog to page 1120mm thick 25mm thick, 38mm thick, 42mm thick General Specifications Material Expected Life Frame: Aluminum, Impeller:Plastics (Flammability: UL94V-1) Refer to specifications (L10:Survival rate: 90% at 60 , rated voltage,and continuously run in a free air state) 50/60Hz 1,500VAC 1minute (between input terminal and frame or between lead conductor and frame Black, 2pcs 30 to 70 (Non-condensing Voltage of each model 10% Dielectric Strength Lead Wire Storage Temperature Operating Voltage Range Locked Rotor Current Rated Speed A Operating Temperature Expected Life Lead Wire AWG22 UL1430 Rotating...
Open the catalog to page 12Finger guards color Model: 109-049C Surfacetreatment : Nickel-chrome plating (silver) Outlet side Model: 109-049E Surfacetreatment : Nickel-chrome plating (silver) : 109-049H : Cation electropainting (black) Inlet side. Outlet side Resin finger guards Resin filter kits ■ Air Flow - Static Pressure Characteristics
Open the catalog to page 13San Ace 80 20mm thick 25mm thick, 38mm thick, 42mm thick General Specifications Material Expected Life Dielectric Strength Storage Temperature Operating Voltage Range Frame: Aluminum, Impeller:Plastics (Flammability: UL94V-1) Refer to specifications (L10:Survival rate: 90% at 60 , rated voltage,and continuously run in a free air state) 50/60Hz 1,500VAC 1minute (between input terminal and frame or between lead conductor and frame 30 to 70 (Non-condensing Voltage of each model 10% Locked Rotor Current Rated Speed Operating Temperature Expected Life Rotating Direction Reference Dimension of...
Open the catalog to page 14Finger guards Resin finger guards Options Unit : mm Model 109-1002G Color Surface treatment Nickel-chrome plating silver Outlet side 101.2 Color Surface treatment Nickel-chrome plating silver Cation electropainting black Resin filter kits Model 109-1002F13 13PPI 109-1002F30 30PPI Inlet side, Outlet side Plug cord (UL/CSA CERTIFIED) UL FILE No.E50197 CSA FILE No.LR67048 Model 489-047-L10 /489-047-L21 (Products compliant with Electrical Appliance and Material Safety Law) Model 489-016-L 10 /489-016-L 21 Power cord length(mm) mm 1,000 2,100 Air Flow - Static Pressure Characteristics Static...
Open the catalog to page 1520mm thick 25mm thick, 38mm thick, 42mm thick General Specifications Material Expected Life Frame: Aluminum, Impeller:Plastics (Flammability: UL94V-1) Refer to specifications (L10:Survival rate: 90% at 60 , rated voltage,and continuously run in a free air state) 50/60Hz 1,500VAC 1minute (between input terminal and frame or between lead conductor and frame 30 to 70 (Non-condensing Voltage of each model 10% Dielectric Strength Storage Temperature Operating Voltage Range Locked Rotor Current Rated Speed min-1 Operating Temperature Expected Life Rotating Direction Reference Dimension of...
Open the catalog to page 16Finger guards Resin finger guards Options Unit : mm Model 109-1002G Color Surface treatment Nickel-chrome plating silver 101.2 Color Surface treatment Nickel-chrome plating silver Cation electropainting black Resin filter kits Model 109-1002F13 13PPI 109-1002F30 30PPI Inlet side, Outlet side Plug cord (UL/CSA CERTIFIED) UL FILE No.E50197 CSA FILE No.LR67048 Model 489-047-L10 /489-047-L21 (Products compliant with Electrical Appliance and Material Safety Law) Model 489-016-L 10 /489-016-L 21 Power cord length(mm) mm 1,000 2,100 Air Flow - Static Pressure Characteristics Pa Static Pressure
Open the catalog to page 17All SANYO DENKI America catalogs and technical brochures
-
San Ace Cooling Systems
52 Pages
-
San Ace 40L
4 Pages
-
San Ace Cooling Fan
673 Pages
-
San Ace 120AD 9AD type
4 Pages
-
San Ace 92 9RA type
4 Pages
-
San Ace 92 9GA
5 Pages
-
San Ace 140W 9WL
5 Pages
-
San Ace 140L 9LG
5 Pages
-
San Ace 92W 9WL
3 Pages
-
San Ace B97 9BMC
2 Pages
-
Splash Proof Fan Catalog
126 Pages
-
Oil Proof Fan Catalog
126 Pages
-
Long Life Fan Catalog
91 Pages
-
SANMOTION R 3E
172 Pages
-
SANMOTION T
36 Pages
-
SANMOTION F5
128 Pages
-
SANMOTION F2
84 Pages
-
SANMOTION C
12 Pages
-
DC Fan Catalog
247 Pages
-
San Ace 92W
4 Pages
-
San Ace B97
2 Pages
-
San Ace 172 GP
4 Pages
-
San Ace 40
2 Pages
-
San Ace 60T
2 Pages
-
Blower
20 Pages
-
Electrolytic Corrosion Proof Fan
11 Pages
-
PWM Controller
4 Pages
-
SANMOTION MODEL No.PB
2 Pages
-
ACDC Fan
5 Pages
-
Reversible Flow Fan
4 Pages
-
DC San Ace Catalog
378 Pages
-
SANMOTION R
40 Pages
-
SANMOTION R 400V
36 Pages
-
SANMOTION R Medium Capacity
40 Pages
-
SANMOTION R ADVANCED MODEL
64 Pages
-
1 to 20kVA Modular UPS: A11J
12 Pages
-
1 to 5kVA Modular UPS: ASE-H
6 Pages
-
Online UPS: A11H
4 Pages
-
Hybrid UPS
8 Pages
Archived catalogs
-
AC_San_Ace
56 Pages
-
DC_San_Ace
332 Pages
-
PD-D11A
8 Pages