SANWA GENERAL CATALOG - Sanwa Electric Instrument - #4

/ 26


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
Pages:


See other catalogues for Sanwa Electric Instrument

Text version of the page
igital Multimeters
| High accuracy & high resolution (PC Link)
PC5000
What is Digital Multimeter?
Advantages of digital multimeters (DMMs)
□□□□□□□
50000 & 500000 Count
■ 4-4 / 5 digits 50000 count
(Selectable 5-4 / 5 digits 500000 count for DCV 5 Hz)
■ 0.03% best accuracy
■ AC / AC + DC True RMS
■ Fast speed bar graph
■ Capacitance measurement (5000 count)
■ 4-20mA% measurement
dBm 20 selectable reference impedance Line frequency (AC sine wave) measurement
■ Logic frequency measurement Duty cycle measurement
■ Capture (peak hold) 0.8ms in duration
■ MAX, MIN, MAX-MIN recording mode
■ Peak hold
■ Data hold, Range hold
■ Relative value
■ Auto power off(17min.) (cancelable) ■Alarm for improper test lead insertion to current
terminal
Protective holster with wall hanger and lead holder
■ Tilt stand
■ Optical link RS232C / USB interface (optional)
Display : numeral display 50000 S 500000 selectable
Bar graph 52 segments Sampling rate : 5 times / sec. for 50000 count numer­al display , 1.25 times / sec. for 500000 count numer­al display 60 times / sec. for bar graph Bandwidth : V : 45Hz--1kHz, 1kHz--20kHz (below 500V),
A:45Hz--1kHz Safety : IEC61010-1 (EN61010-1) 2001-02 CAT.Ill 600V
Max./CAT.IMOOOVMax. Battery life : Approx. 120h (alkaline battery) at DCV range
A digital multimeter is a convenient measuring instrument that allows by itself the measurement of DC voltage, AC voltage, DC current, AC current and resistance (Pocket type DMM normally cannot be used for the measurement of current for safety reasons). In addition to these basic measuring functions, most models are provided with features such as a diode test function and con­tinuity buzzer. Some of recent products feature the measure­ment of frequency and capacitor capacity. Some have added functions of maximum and minimum value hold and relative val­ue measurement as well as data hold and range hold functions. The advent of DMMs (PC series) connectable to a PC makes it possible to let a PC assume the function of expensive recording meters and recorders.
Highly accurate measurement. Higher accuracy (1% or less) compared with an analog multimeter (approximately 3%).
1
DCV
500rrV5/50/500/1000V
±
0.03°/
+2)
0.01mV
10MO
ACV
500rrV5/50/500/1000V
+
0.8%
60)
0.01mV
DCA
500jj/5m/50rn/500rn/5/10A
±
0.1%
20)
O.OIjjA
ACA
500jj/5m/50rn/500rn/5/10A
±
1.0%
40)
O.OIjjA
Resistance
500/5k/50k/500k/5M/50MO
±
0.2%
6)
0.01O
Capacitance
50n/500n/5jj/50jj/500jj/9999jjF
±
0.8%
3)
0.01 nF
Frequency
5Hz--200kHz
±
0.002
/o+4)
0.0001Hz
Logic freque
ncy 5 Hz—-2MHz
±
0.002
/o+4)
0.0001Hz
Duty cycle
0.1%—99.99%
±
3d/k
z+2)
dBm
-11.76dBm--54.25dBrn at 600Q
±
0.25dB+2)
'Tnnnnr»
JUUUUU
Reduced measuring loss due to high internal impedance (low voltage drop between terminals).
±25d d 200O. Oner
4--20rnA% Continuity
\=0%,20mA=100%
No reading error. No parallax error and reading error by a user as occurs with an analog multimeter.
Bandwidth
V : 45Hz--1kHz 1 kH
■-20kHz (b
low 500V) , A : 45Hz--1k
Hz
Fuse
12.5A/500V IR20kA
#6.3X32
0.63A/250V IR1.5kA q>
5.2X20
Battery
6LF22(9V)X1
Size / V\feight
H179XW37XD55mrn
/460g(inc
uding holster)
Standard
Testlead(TL-82),Ho
ster(H-50)
Clip adapter(CL-13) ,
■•I.UM.mTEfgEEnEEM
Measurement
Four key points in choosing a suitable model
Software : PC Link , PC Link Plus
Optical PC link cable : KB-RS2 , KB-USB2
Clamp probe : CL124, CL140, CL-20D, CL-22AD, CL33DC
Temperature probe : T-300PC (PC Link software will be nec
Test lead : TL-21M
Carrying case : C-CD
Voltage, Resistance measurement
I. What are the necessary measuring functions?
Choose the necessary functions, except voltage and resistance measurement, (including need for the measurement of current (400mA, 10A, 12A, 20A), ca­pacitor, frequency, temperature and measurement of 4-20mA, etc.)
2. Other necessary functions
Functions required differ depending on where the measurement is taken.
1) To record measured values concurrently with the process of measurement
To fix data by the data hold function. To secure the test lead in the holster.
2) To check changes in measured values
Measurement of maximum values, minimum val­ues, and relative values.
3. For measurements of waveforms of non-sine waves, choose a modei supporting measurements by RMS values.
In measuring distorted sine and non-sine waves (sq­uare wave, triangular wave, pulse), significant errors occur in measurement by models making measure­ments by mean values.
There are two types of RMS values.
AC-Coupled true RMS value: Adapted to measure­ments of distorted sine and non-sine waves of the AC AC + DC-coupled true RMS value: Adapted to meas­urements of waveform containing a DC component.
4. Other functions
There are other types including a function to transfer data during measurement to a PC in real time and a function to record measured data in a built-in memory. To transfer data to a PC, optional connecting cables and data retrieval software (PC Link or PC Link Plus) are required in addition to a DMM of PC series.
In making measure­ments, connect your DMM in parallel with an object to be measured. Do not apply signals ex­ceeding the maxi­mum rated input vol­tage.
High accuracy & built-in memory(PC Link) ^^^^
PC520M KJ£3
43,000 points data logging in built-in memory
■ 3-4 / 5 digits 5000 count
■ 0.08% best accuracy HAC True RMS
■ Fast speed bar graph Capacitance measurement
K type temperature -50°C~1000°C
iSOptional accessory K-AD is necessary. iSK type temp, sensor K-250PC is included as a standard accessory.
■ Frequency measurement (AC sine wave only)
■ Data hold / Range hold
■ Auto power off(17min.) (cancelable) Test lead resistance zero adjustment function
■Alarm for improper test lead insertion to current terminal
Protective holster with wall hanger and lead holder
■ Tilt stand
■ Optical link RS232C / USB interface (optional)
Data Logging Mode
■ 43,000 data points in built-in memory Selection of measurement inerval 0.05s/1 s/20s/40s/1 min/2min/4min/8min (DCV, ACV, DCA, ACA) 0.2s/1s/20s/40s/1min/2min/4min/8min (°C, O) 0.4s/1 s/20s/40s/1min/2min/4min/8min(Hz) Auto-standby mode during data logging to extend battery life
Auto-stop of data logging when batteries are low to guarantee accuracy of every logged datum Export logged data to PC
Display : numeral display 5000 , bar graph 52 segments Sampling rate : 5 times / sec, 60 times / sec. for bar graph Bandwidth :40Hz-~20kHz (below500V) ,40Hz-~1kHz (ACA) Safety : IEC61010-1 (EN61010-1) 2001-02 CAT. Ill 600V
Max./CAT. II 1000V Max. Battery life : Approx. 150h (alkaline battery) at DCV range
EaB3ElE3E2
Current measurement
In making measure­ments, connect your DMM in series with an object to be measured. Do not apply signals exceeding the maxi­mum rated input cur­rent.
DCV
50m/500m/5/50/500/1000V
±(0 08%+2) 001mV ]0MQ
50m/500m/5/50/500/1000V
±(0.5%+3) 0.01mV
DCA
500jj/5rn/50rn/500rn/5/10A
±(0.2%+4) 0.1jjA
5 OOjj/5 m/5 0 m/5 0 Om/5/1 0 A
±(0.6%+3) 0.1jjA
Resistance
50/500/5k/50k/500k/5M/50MO
±(0.2%+2) 0.01O
50n/500n/5jj/50jj/500jj/9999jjF
±(0.8%+3) 0.01 nF
Temperature
-50°G-1000°C (thermocouple K type)
±(0.3%+3) 1°C
Frequency 5Hz~125kHz ±(0.01%+2) 0.001Hz
Continuity
Buzzer sounds at between 20Oand 1
20O. Open voltage : approx. 3V
Diode test
Open voltage : approx. 3.5V
Bandwidth
40Hz--20kHz (below 500V) 40Hz~1
Hz (ACA)
Fuse / Battery
12.5A/500V IR20kA ^.3X32 0.63A/250V IR1.5kA ^.2X20
6LF22(9V) X1
Size / VXfeight
H179XW37XD55mrrV460g(includin
holster)
Standard
Test lead (TL-82), Holster(H-50), Th Clip adapter(CL-13), Instruction man
eimocouple Ktype (K-250PC),
Software : PC Link, PC Link Plus
Optical PC lin
k cable : KB-RS2, KB-USB2
Clamp probe
CL124, CL140, CL-20D, CL-22AD, CL33DC
Temperature
orobe : T-300PC (PC Link softwa K-8-250--800
ewill be necessary to use.),
K type adapte
r : K-AD
When the black test lead is connected to the cathode side of the diode and the red test lead to the anode side, the forward voltage can be measured. In contrast, if the black test lead is connected to the anode side of the diode and the red test lead to the cath­ode side, the reverse voltage can be meas­ured and "OL" display appears.
Test lead : Carrying c
06
07
http://www.sanwa-meter.co.jp
http://www.sanwa-meter.co.jp

pageCatalog pdf di En 2012-02-07-17