E series

E series
1 / 15 PagesView full catalog

E series

Product catalog summary
General Features
The flow divider is composed of modular elements with gears connected by an internal coupling sleeve, ensuring synchronized rotation. It utilizes hydraulic power, reducing the need for multiple pumps and mechanical couplers, offering precision and minimizing energy loss.
Working Conditions
- Minimum fluid viscosity: 12 mm²/sec
- Maximum starting viscosity: 800 mm²/sec
- Suggested viscosity range: 17 - 65 mm²/sec
- Operating temperature: -15 to 85°C
- Hydraulic fluid: Mineral oil
Specifications
Flow dividers can function as pressure intensifiers, allowing higher pressure between sections. For inlet flows over 80 l/min, technical consultation is recommended. Detailed specifications include displacement, maximum outlet pressure, and flow per section for various models.
Applications
Used in systems requiring independent hydraulic circuits, such as lifting platforms, hydraulic presses, and military installations. They also amplify pressure in systems needing higher operating pressures.
Displacement Selection
Maintain speed within the recommended range with a maximum pressure difference of 50 bar between stages to equalize flow. Flow deviation is kept within ±2% under these conditions.
Guidelines for Port Combination
For multiple inlets, configurations should have one inlet per 80 l/min of flow. Pressure differences between elements should not exceed 50 bar for precision.
Available Valves
Relief valves realign cylinders at the end of their cycle, preventing damage. Overload and anti-cavitation valves are adjustable and include security features to prevent sticking.
Available Ports
Includes BSPP and SAE threaded ports, with specific dimensions for each model.
Assembling Dimensions
Detailed dimensions for assembling with and without valves, including specific measurements for each model type.
Ordering Information
Outlines a coding system for ordering, specifying type, cover, stages, displacement, and port configurations.
Overview
This document provides technical specifications and ordering instructions for Salami S.p.A.'s 2DRE-AR rotary flow dividers and flow equalizers, including seal options, port configurations, valve types, and displacement measurements.
Seal Options
Standard seals are Buna nitrile, with Viton seals available using the code 'V'.
Port Configurations
Specifies GAS threaded ports (BSPP) and SAE threaded ports (ODT). Configuration requires specifying type, cover options, stages, displacement, and port types.
Valve Types
Includes adjustable overload valves, anti-cavitation valves, and combinations thereof, with specific codes for each type.
Displacement Measurements
Options provided in cubic inches per revolution and cubic centimeters per revolution, with a range of values for different applications.
Ordering Instructions
Outlines a key code method for ordering, specifying type, cover options, stages, displacement, port types, valve type, and pressure settings. Maximum stages are six; for more, consult the technical department.
Contact Information
Contact details for Salami S.p.A. and its international branches in Spain, France, and the USA are provided for further inquiries and support.
See more

Catalog excerpts

E series-1

GEAR FLOW DIVIDERS Technical Catalogue

 Open the catalog to page 1
E series-2

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS GENERAL FEATURES A ow divider is composed of two or more modular elements (stages) with gears mechanically linked by an internal coupling sleeve, between the shafts, that causes them to turn at the same speed.Unlike multiple pumps, in which the input power is mechanical (shaft connected to a motor), in a ow divider the input power is hydraulic, i.e. a ow of oil under pressure supplies the modular elements, which are in turn connected to the hydraulic circuits serving the users. Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected]...

 Open the catalog to page 2
E series-3

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS 2DRE Typical applications of ow dividers Examples of this kind of application: • lifting platforms and bridges; • hydraulic bending presses and shearing machines; • hoisting of freight containers; • lubrication systems; • hydraulic opening / closing of gates; • automatic hydraulically-driven machines; • actuation of formwork for construction; • wood processing machinery; • conveyance of trolleys driven by hydraulic cylinders or motors; • equipment for the food industry; • military installations. Pressure ampliers. When in a hydraulic system one user requires...

 Open the catalog to page 3
E series-4

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS In order to equalize the ow, it needs to maintain the speed within the suggested speed range, with a Δp max. of 50 bar (725 psi) between the different stages.Keeping these conditions, we can assure a ow deviation, within ± 2% on the different stages. n = number of section Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected] CALCULATION EXAMPLE Flow equalizer (diagram page 4): suppose we have to supply two cylinders, both with the same ow of 30l/min. The ow equalizer’s inlet ow Q0, delivered by the pump, will be 60 l/min....

 Open the catalog to page 4
E series-5

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS Allt he data here showed were carried outw ithm ineral oila tt he temperatureo f 50°Cw ithv iscosity of 22 cSt Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected] Performancer ange

 Open the catalog to page 5
E series-6

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS GUIDELINE FOR THE COMBINATION OF THE PORTS These drawings give only an overview of the different combinations of inlet and outlet working ports. Anyway, to x the correct number and size of inlet working ports, please get in touch with our technical dept. Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected] In this table, the number of inlets in function of the number of elements are indicated. For ow dividers with many inlets, as they are all communicating it is even possible to use only one of them, by plugging the other...

 Open the catalog to page 6
E series-7

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS OVERLOAD VALVE (setting range from 50 to 275 bar - 725 to 4000 psi ) On the 2DRE-VA, this valve is available just set 50 bar Wrench 22 Dimension from the top valve, see page 8 Flow (l/min) OVERLOAD AND ANTI-CAVITATION VALVE (setting range from 50 to 275 bar - 725 to 40 00 psi ) ANTI-CAVITATION VALVE Flow (l/min) Both valves VA and AR are adjustable without oil leaking. Further more both have a security device to avoid valve sticking Flow (l/min) Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected] Relief valves are used...

 Open the catalog to page 7
E series-8

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected] PORTS Type British standard pipe parallel (BSPP) Y

 Open the catalog to page 8
E series-9

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS ASSEMBLING DIMENSIONS (release without valves) Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected]

 Open the catalog to page 9
E series-10

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS ASSEMBLING DIMENSIONS (release with valves/external discharge ) Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected] Outlet side

 Open the catalog to page 10
E series-11

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS ASSEMBLING DIMENSIONS (release with valves/internal by-pass) 47.2 (1.86) Salami S.p.A. Via Emilia Ovest, 1006 - 41123 Modena tel. +39 059 387411 [email protected]

 Open the catalog to page 11
E series-12

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS Keeping the above drawing as reference point, looking the flow divider from the height, maintaining the outlet ports always at the same side we will be able to fix all the features.Please, have a look on the example here below in order to understand the key code method. 0,27 cu.in/rev. 0,40 cu.in/rev. 0,50 cu.in/rev. 0.65 cu.in/rev. 0,68 cu.in/rev. 0.77 cu.in/rev. 0,84 cu.in/rev. 1.01 cu.in/rev. 1.15 cu.in/rev. 1.37 cu.in/rev. 1.58 cu.in/rev. 1.84 cu.in/rev. Without inlet port With inlet port OUTLET PORT SIDE COVER INLET PORT SIDE COVERS OUTLET PORT Salami...

 Open the catalog to page 12
E series-13

ROTARY FLOW DIVIDERS AND FLOW EQUALIZERS 2DRE-AR HOW TO ORDER (release with valves/external discharge ) Keeping the above drawing as reference point, looking the flow divider from the height, maintaining the outlet ports always at the same side we will be able to fix all the features.Please, have a look on the example here below in order to understand the key code method. 0,27 cu.in/rev. 0,40 cu.in/rev. 0,50 cu.in/rev. 0.65 cu.in/rev. 0,68 cu.in/rev. 0.77 cu.in/rev. 0,84 cu.in/rev. 1.01 cu.in/rev. 1.15 cu.in/rev. 1.37 cu.in/rev. 1 . 5 8 c u. in/re v. 1 . 8 4 c u. in/re v. Adjustable overload...

 Open the catalog to page 13
E series-14

Keeping the above drawing as reference point, looking the flow divider from the height, maintaining the outlet ports always at the same side, we will be able to fix all the features, PI ease, have a look on the example here below in order to understand the key code method. Max number of stages 6, for assemblings which need of more steges, please get in touch with our technical dept. Amending as per our example above, when you have to sot up a 2DRE flow divider, beginning from ;he right side you have to specify: first cover (with or without inlet port or pre-arranged for overload valve VA) ^ stages,...

 Open the catalog to page 14
E series-15

GEAR FLOW DIVIDERS Dealer Spare Parts Catalogue TM SALAMI spa via Emilia Ovest 1006 41100 Modena Italy telefono +39-059-387411 telefax +39-059-387500 [email protected] - www.salami.it SALAMI ESPAÑA Poligono Industrial Armenteres C/Primer de Maig, 18, Nave 4 08980 San Feliu de Llobregat Barcelona telefono +34-93-6327288 telefax +34-93-6667826 [email protected] SALAMI FRANCE 22, rue Louis Saillant 69120 Vaulx en Velin Lyon telefono +33-04-78809941 telefax +33-04-78803669 [email protected] SALAMI HYDRAULICS N.A INC Loop Road Baldwinsville NY 13027 - USA Tel.: +1-315-295-2363 Fax.: +1-315-295-2364...

 Open the catalog to page 15

All SALAMI catalogs and technical brochures

  1. 2PE

    42  Pages

  2. 3PE and 3ME

    53  Pages

  3. 1,5PE

    41  Pages

  4. VD10A - VD12A

    32  Pages

  5. PG330

    34  Pages

  6. PLC series

    11  Pages

  7. VDP08

    46  Pages

  8. VDP8

    42  Pages

  9. VDM8 series

    38  Pages

  10. VDM9

    22  Pages

  11. VDM6A series

    35  Pages

  12. VDM6

    38  Pages

  13. VD8A series

    48  Pages

  14. VD6A series

    56  Pages

  15. PG301 series

    13  Pages

  16. H series

    33  Pages

  17. E series

    13  Pages

  18. E series

    26  Pages

  19. B series

    32  Pages

  20. E series

    20  Pages

Archived catalogs

  1. Product range

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.