Catalogue General catalogue
www.sacemi.com
print switch display
Page / 56
Where to buy
this product ?
Request
a Quote
Sacemi Elettropompe - 2547, 3262, 3549
/ 56
See all the products Sacemi Elettropompe
Text version of the page
Type AP 100 A--112 A-B
Usages:
These pumps are suitable for transferring liquids containing impurities measuring up to 2 mm.
The hydraulic components, namely the cast-iron impeller and scroll and the steel pump body,
allow the pumps to be used with water, emulsions and oily substances in general with a
maximum viscosity of 3° Engler (21 CST).
The temperature of the liquid must not exceed 90° C.
They are usually used on:
• Machine tools (milling machines-lathes-work centres)
• Glass processing machines
• Surface treatment systems
• Filtration systems
They should usually be installed at about 6 - 7 cm. from the base of a tank, with a capacity in proportion to the flow rate. It is important to check that the maximum level of the liquid in the tank always remains 3 - 4 cm. lower than the flange (see figure).
In cases where the liquid is particularly dirty, the user is recommended to construct the tank in compartments to allow the dirt to deposit before it is stirred up by the pump. For other usages you are advised to consult our technical office.
Table of dimensions and weights
TYPE
A
B
C
D
0E
0F
0G
0H
0I
0L
M
N
Kg.
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
700
320
48
AP100A
830
450
380
280
240
1-1/4"
2-1/2"
300
270
13
170
136
54
990
610
N. 4
56
1240
860
58
730
320
59
AP 112A
860
450
410
280
240
1-1/2"
2-1/2"
300
270
13
170
136
65
1020
610
N. 4
67
1270
860
69
730
320
61
AP 112B
860
450
410
320
240
2"
2-1/2"
300
270
13
190
145
67
1020
610
N. 4
69
1270
860
71
Electrical features
Type
KW. Input
Hz. 50
Hz. 60
230/400
254-290/440-500
230/400
208-230/440-460
254-290/440-500
318-346/550-600
AP 100 A
4,80
14,5/8,4
11,0/6,3
17,3/10
14,8/8,6
14,5/8,4
11,4/6,0
AP 112 A
5,50
19,2/11
14,5/8,4
23,8/13,8
19,4/11,2
19,2/11
15,2/8,7
AP 112 B
6,00
21,0/12,2
16,0/9,2
25,2/14,5
21,4/12,4
21,0/12,2
16,6/9,6
0 200 400 600 800 1000
Q [l/min] - volumetric delivery
The data of this diagram are referred to a viscosity not higher than 5 CST 20° c. |
44
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-56
pdf-page pdf di En 2008-12-49-05