Halogen-free Cables
1 /63Pages

Halogen-free Cables

Halogen-free Cables
1 /63Pages

Catalog excerpts

Halogen-free Cables-1

Halogen-free Cables

 Open the catalog to page 1
Halogen-free Cables-3

SRBIX® cables can be fully recycled and in separate components newly supplied to the resource cycle. Cables with SRBIX® FRNC outer sheath avoid flame propagation in case of local flaming and are flame retardant and selfextinguishing acc. to VDE, EN and IEC. They fulfil the smoke density acc. to IEC, EN, VDE and BS. Halogen-free cables especially for use in rail vehicles acc. to EN 45545-2 You will find halogen-free Ethernet cables especially for use in rail vehicles in chapter E You will find Besilen® insulated strands for use in rail vehicles in chapter K

 Open the catalog to page 3
Halogen-free Cables-4

Halogen-free Cables Applications Typical areas of application for halogen-free cables Halogen-free cables are applicable in delicate areas as, for example, public buildings and institutions or railway vehicles and in areas where the general safety requirements for cables are very high. Besides being halogen free acc. to EN 50306-1 + EN 50264-1 the used cables have to be flame retardant and self extinguishing and are not allowed to enhance flame propagation. This is why halogen-free cables are mandatory in many cases. In addition, flexible application is often desired. All those cha- racteristics...

 Open the catalog to page 4
Halogen-free Cables-5

Halogen-free Cables Applications Application of halogen-free C data cables Data cables are used for the transmission of signals, measuring values and control signals in electronic control appliances, data processing systems, railway technologies, weighing installations, office appliances or wherever smallest cross sections, bending radii, shielding or high flexibility is demanded. The paired, halogen-free C data cables are designed for increased requirements on transmission characteristics and near-end cross talk attenuation. The excellent characteristics of these cables, in various versions...

 Open the catalog to page 5
Halogen-free Cables-6

Halogen-free Cables Single conductor screened coloured cores numbered cores twisted pairs inner sheath +220 °C + 90 °C + 85 °C – 30 °C – 40 °C – 50 °C Temperature range fixed laying* Basic construction Cable type Selection table Peak operating voltage: < 0,25 mm² = max. 350 V ≥ 0,25 mm² = max. 500 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 450/750 V Nominal voltage Uo/U 0,6/1 kV Voltage UL resp. CSA 600 V Voltage UL resp. CSA 1000 V Testing voltage 1500 V Testing voltage 2000 V Testing voltage 2500 V Testing voltage 3000 V Testing voltage 4000 V Halogen-free acc. to IEC 60754-1 + VDE...

 Open the catalog to page 6
Halogen-free Cables-7

• from *The temperature range for flexible application is mentioned on the corresponding catalogue page to

 Open the catalog to page 7
Halogen-free Cables-8

Halogen-free CablesSelection tableCables for Railway Technology acc. to EN 45545-2 Cable type • from *The temperature range for flexible application is mentioned

 Open the catalog to page 8
Halogen-free Cables-9

Halogen-free Cables Selection index CharacteType ristics approvals Standards from Data cable Control cable Power cable screened twisted pairs twisted triple Voltage range Temperature range fixed laying* Cable type + 90°C – 40°C Peak operating voltage max. 300 V Peak operating voltage max. 350 V Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 0,6/1 kV Testing voltage 1500 V Testing voltage 2000 V Testing voltage 4000 V Halogen-free acc. to IEC 60754-1 + VDE 0482-754-1 Fire performance: no flame propagation acc. to IEC 60332-3-22 + VDE 0482-332-3-22 Cat. A Fire performance: flame retardant...

 Open the catalog to page 9
Halogen-free Cables-10

Halogen-free Cables Selection index Data cable Control cable screened twisted pairs Voltage range Temperature range Construction fixed laying* Cable type continuously flexible with highest fire protection + 90 °C – 40 °C Peak operating voltage < 0,25 mm² = max. 350 V ≥ 0,25 mm² = max. 500 V Nominal voltage 0,6/1 kV Testing voltage 1500 V Testing voltage 4000 V Halogen-free acc. to IEC 60754-1 + VDE 0482-754-1 No flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25 Cat. C resp. D Flame retardant and self-extinguishing acc. to IEC 60332-1-2, VDE...

 Open the catalog to page 10
Halogen-free Cables-11

» flame retardant and self-extinguishing » very good stripping » flexible » fulfils fire protection requirements R15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3 » flame retardant acc. to UN/ECE R118 » PFAS free Halogen-free CablesSfiBIX® A 146 FRNC SfiBIX® A 156 FRNC warn BROCKSKES ■ D-VIERSEN ■ SfiBIX* A 146 FRNC 300/500 V 0,5 mm2 C marking example: SOB BROCKSKES ■ D-VIERSEN ■ SfiBIX® A 146 FRNC 300/500 V 0,5 mm2 C Construction: Technical Data: Conductor: bare copper strands Nominal voltage: SfiBIX* A 146 FRNC: SfiBIX* A 156 FRNC: Temperature range Outstanding features: » halogen-free...

 Open the catalog to page 11
Halogen-free Cables-12

Halogen-free Cables S A 166 FRNC wiring cable with improved fire performance and extended temperature range 0.6/1 kV BRÖCKSKES · D-VIERSEN · S A 166 FRNC 0,6/1 kV 1,5 mm² C marking example: S BRÖCKSKES · D-VIERSEN · S A 166 FRNC 0,6/1 kV 1,5 mm² C Technical Data: Construction: bare copper strands acc. to IEC 60228, VDE 0295, class 5 Nominal voltage: Testing voltage: Colour code: Min. bending radius: For one single bend: Temperature range fixed laying: flexible application: Fire performance: No flame propagation acc. to IEC 60332-3-24 + VDE 0482-332-3-24 resp. IEC 60332-3-25 + VDE 0482-332-3-25...

 Open the catalog to page 12
Halogen-free Cables-13

marking example: SOB BROCKSKES ■ D-VIERSEN ■ SfiBIX® A 147 FRNC 300/500V 0,5 mm2 20 AWG U AWM Style 10528 75°C 60OV C Conductor: tinned copper strands Insulation: SfiBIX” Colour code: see table* Outstandiung features: » halogen-free » no flame propagation » flame retardant and self-extinguishing » UL recognized » PFAS free Technical Data: Nominal voltage: SfiBIX* A 147 FRNC: SfiBIX* A 157 FRNC: Voltage UL: SfiBIX* A 147 FRNC: SfiBIX* A 157 FRNC: Testing voltage: SfiBIX* A 147 FRNC: SfiBIX* A 157 FRNC: Temperature range DIN/VDE: UL: up to + 75 °C Fire performance: no flame propagation acc. to...

 Open the catalog to page 13
Halogen-free Cables-14

Halogen-free Cables SRBIX® A 100 HT SRBIX® A 101 HT high temperature resistant single conductor with nickel-plated strands high temperature resistant single conductor with silver-plated strands warn BROCKSKES ■ D-VIERSEN ■ SflBIX* A 100 HT ■ 220°C ■ C marking example: SflB BROCKSKES ■ D-VIERSEN ■ SflBIX® A 100 HT ■ 220°C ■ C nickel-plated copper strands SRBIX* A 101 HT: silver-plated copper strands fine wires Insulation: SRBIX” Colour code: see table* » halogen-free » high temperature resistant » flexible » PFAS free » SRBIX* A 101 HT: good solderability Technical Data: Nominal voltage: Uo/U...

 Open the catalog to page 14

All SAB BROECKSKES GMBH & Co. KG catalogs and technical brochures

  1. Dynamic Cables

    22  Pages

  2. Data Cables

    22  Pages

  3. Cable Asseblies

    36  Pages

  4. Tray Cables

    19  Pages

  5. Tactical Cables

    12  Pages

  6. Reeling Cables

    16  Pages

  7. Handling Cables

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.