MSA 650
System resolution
Accuracy Matting Max. velocity grades pitch (Edge separation amin)
continuous momentary
Signal-outputs (optional):
Scale model
• Sinusoidal micro-current signals MSA650.13
+5 V ±5%, max. 90 mA
Output signals:
Encoder signals: 7 to 16 uApp,
typical 11.5 uApp at 1 Kn
Reference pulse: 2 to 8 uA,
typical 5 uA (useable component) at 1 Kn
Max. output frequency: 100 kHz (with 3 m cable)
Sinusoidal micro-current signals
MSA 650.13
depending on external subdividing
±5, ±10 um/m
20 um
1 m/s
2 m/s
Square wave Line Driver signals with integrated Subdividing
MSA 650.24
10 urn
±10 um/m
40 um
1 m/s (5 us)
2 m/s (2.5 us)
MSA 650.23
5 um
±5, ±10 um/m
20 um
1 m/s (2.5 us)
2 m/s (1.2 us)
MSA 650.33
2.5 um
±5, ±10 um/m
20 um
1 m/s (1.2 us)
1 m/s (1.2 us)
MSA 650.64
2 um
±5, ±10 um/m
40 um
1 m/s (800 ns)
2 m/s (400 ns)
MSA 650.63
1 um
±5, ±10 um/m
20 um
1 m/s (40 0 ns)
1 m/s (400 ns)
MSA 650.73
0.5 um
±5, ±10 um/m
20 um
1 m/s (20 0 ns)
1 m/s (20 0 ns)
• Square wave signals (single ended) with integrated Subdividing Electronics
• Square wave signals (differential) via Line Driver RS 422 standard
with integrated Subdividing Electronics
MSA 650.23 = times1
MSA 650.24 = times1
MSA 650.33 = times2
MSA 650.63 = times5
MSA 650.64 = times5
MSA 650.73 = times10
Power supply:
+5 V ±5%, < 150 mA (with interpolation, unloaded)
< 200 mA (without interpolation, unloaded)
Other accuracy grades or grating pitches (e.g. Inch) upon request
Standard measuring lengths: (mm)
170, 220, 270, 320, 370, 420, 470, 520, 620, 720, 770, 820, 920, 1040, 1140, 1240, 1340, 1440, 1540, 1640, 1740
Measuring type: glass scale
Reference Mark (RI): selectable MSA 650.xx K:
Distance coded Reference Marks (K): after travelling 20 mm the absolute position will be shown on the display.
MSA 650.xx:
Up to a measuring length of 920 mm, one Reference Mark can either be placed in the middle of scales 1040 mm or longer, or 35 mm from either end of measuring length. With a measuring length of 1040 mm or longer, a Reference Mark will be placed 45 mm from either end of the measured length.
Option:
One Reference Mark at any location, or two or more Reference Marks separated by distances of n x 50 mm
Required moving force:
with standard sealing lips < 3 N
with low drag sealing lips < 0.2 N
Environmental sealing DIN 40050: IP 53 (with standard sealing lips)
Permissible vibration: 80 m/s2 (40 to 2000 Hz) Permissible shock: 200 m/s2 (8 ms)
Permissible temperature:
-20°C to +70°C (storage), 0°C to +50°C (operation) Weight (approx.)
0.8 kg/m (scale spar) + 85 g (scanning head without cable)
34
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
pdf-page pdf di En 2009-01-02-08