New Model – SKORPION without Blower MAXIMUM AIR TEMPERATURE 120V 1.5kW 230V 3.0kW Open ended or with flare 1000°F (540°C) 1400°F (760°C) With high-flow nozzle 1300°F (730°C) 1400°F (760°C) With external air source(Skorpion without Blower) See note* See note* *Note: For models without Blower, the maximum temperature capability of heater will depend entirely on flowrate produced by external air source. The Skorpion blower produces approx. 10 SCFM (283 SLPM) with no additional piping or manifolds attached to heater exit. Higher flowrates than this will result in lower maximum temperatures. SPECIAL NOTES: • Threaded 1” female NPT port is provided for convenient air connection to external air source such as regenerative blower or compressed air. • WARNING: External air supply must be turned ON prior to turning heater ON. • Inlet air pressure must not exceed 5 PSI (.3 Bar) or else air leaks will be noticed in the unit. • For best flow conditions, use min. ¾” NPT size incoming air line. OSRAM SYLVANIA 131 Portsmouth Avenue Exeter, NH 03833 USA Tel: 603-772-4331 Fax: 603-772-1072 2