Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik - #1

/ 8


catalogue search
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 01
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 02
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 03
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 04
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 05
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 06
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 07
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik
P. 08
Pages:
Mineral Insulated Metal Sheathed (MIMS) Resistance Thermometers - Rössel Messtechnik


See other catalogues for Rössel Messtechnik

Text version of the page
www.roesseldresden.de www.roesselwerne.de www.rossel.nl Product Information 170 Mineral-Insulated Resistance Thermometers for Industry, Laboratories and Research Special Advantages: Short response times Mechanically resistant Easily bendable Highly resistant against vibrations 3- and 4-wire circuits from measuring resistor upon request Easy packing and shipment even in the case of long RTD‘s Mineral-Insulated Metal-Sheathed Resistance Thermometer Detectors (MIMS RTD’s) supplement the Mineral-Insulated Metal-Sheathed Thermocoup les (MIMS TC´s), which are tested and approved over many years. MIMS RTD´s can be applied for temperatures from -100 °C up to +550 °C. They combine the advantages of the MIMS RTD´s with tho se of the bendable mineral-insulated metal-shea thed thermocouples. Important advantages of the MIMS RTD´s: · bendable with small radius · suitable for high pressure and vacuum · two-, three- or four-wire circuits are possible · easy packing and shipment even in the case of long RTD´s As supply wires mineral-insulated metal-sheathed cables are used. The supply wires are embedded in a MgO compact insulation and surrounded by a metal sheath of stainless steel. The compact in sulation fixes the wires completely so that they can not be damaged neither by vibration nor by strong bending. Short circuits between the wires or between them and the metal sheath are impos sible. The minimum bending radius depends on the out side diameter of the MIMS cable. About 5 to7 of times the outer diameter is a practicable standard value. The measuring resistor itself complies with the requirements of the DIN EN 60 751:2009 standard. If in special cases, for example in the case of gre at lengths, the inner conductor resistance increa ses more than usual, the resistance is shown on the identification plate. The temperature sensitive length of the RTD is typically 35 mm. Different lengths can be supplied upon request.

pageCatalog pdf di En 2012-06-22-01