| | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | FAKRA- RF Calibration Kit | | |
| | | |
| | | FAKRA- HF Kalibrier- Kit Elektrische Spezifikation | | |
| | | FAKRA- RF Calibration Kit Electrical Specifications | | |
| | | |
| | | | | | | | | | Devices | Parameters Parameter | | | | Open circuits1 Leerlauf (male and female) | Return loss/ Rückflussdämpfung Deviation from nominal phase/ Nominale Phasenabweichung | | | | Short circuits1 Kurzschluss (male and female) | Return loss/ Rückflussdämpfung Deviation from nominal phase/ Nominale Phasenabweichung | | | | Broadband loads Breitband-Last (male and female) | Return loss/ Rückflussdämpfung Resistance/Gleichstrom-Widerstand Power handling/Nennleistung | | | | Adaptors, phase matched Adapter, phasenangepasst | Return loss/ Rückflussdämpfung Accuracy of electrical length/ Toleranz elektrische Länge | | | | | | | | | | | | | | | Specifications | Frequency range in GHz | | | | Spezifikation | | | | | < 0.05 dB | DC to < 1 | | | | < 0.10 dB | > 1 to < 3 | | | | < 0.12 dB | > 3 to < 6 | | | | < 0.5° | DC to < 1 | | | | < 1.5° | > 1 to < 3 | | | | < 2.2° | > 3 to < 6 | | | | < 0.05 dB | DC to < 1 | | | | < 0.10 dB | > 1 to < 3 | | | | < 0.12 dB | > 3 to < 6 | | | | < 0.5° | DC to < 1 | | | | < 1.2° | > 1 to < 3 | | | | < 1.8° | > 3 to < 6 | | | | > 42 dB | DC to < 1 | | | | > 40 dB | > 1 to < 3 | | | | > 36 dB | > 3 to < 6 | | | | 50 ß ± 0.50 ß | DC | | | | < 0.5 W (0° to 50° C) | DC to 6 | | | | > 38 dB | DC to < 1 | | | | > 26 dB | > 1 to < 3 | | | | > 21 dB | > 3 to < 6 | | | | ±0.4 mm | DC to 6 | | | | (±2.9° at 6 GHz) | | | | | | | | | | |
| | | |
| | | 1. The specification for the opens and shorts are given as allowed deviation from the nominal model as defined in the test report included in the kit. | | 1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale Phasenabweichung wie im Testreport angegeben (im Kalibrier- Kit enthalten). | | |
| | | |
| | | Rosenberger connectors specification fulfill in principle the indicated data of the Technical Data. Individual values of connectors may deviate depending upon application, design, type of cable, assembly method and execution. Specific data sheets for particular products can be provided on request from your Rosenberger sales partner. | | Rosenberger- Steckverbinder erfüllen grundsätzlich die in den Technischen Daten angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und - ausführung können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem Rosenberger- Ansprechpartner. | | |
| | | |
| | | Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.de | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | |