You may also be interested in
Temperature data-logger, Transmitter, Data-logger, Pressure data-logger, Hand-held data-logger
Text version of the page
Add intelligence to your cleaning toolsPipeline Data Logger (PDL) - 38191 PDLPipeline Data Logger INSPECTION TECHNOLOGIES PIPELINESALES PRODUCTS ROSENs Pipeline Data Logger (PDL) can be used to measure and record temperature profiles, detect and locate restrictions and deposits, monitor tool behavior, assess cleaning progress and effectiveness, and verify pipeline conditions. The PDL can be attached to any standard cleaning tool and employs fast response, low current sensors which can record for more than 30 days and up to 500 km (310 miles) of inspection. Data are presented in an easy to understand graphical format using supplied software. THE KEY BENEFITS Accurate, robust and reliable Fast, accurate data reporting Attaches to any cleaning tool Supplied with graphical software TIME-BASED RECORDED PROFILES Temperature Absolute and differential pressure profile Thri-axial acceleration (inclination and tool rotation) SIZES PDL 4 Standard applications Pipe size β₯ 4" Operating time 115 250 hours PDL 14 Extended time and range Pipe size β₯ 14" Operating time 30 60 daysPipeline Data Logger 4 THE STANDARD, ADVANCED AND PROFESSIONAL EDITION Temperature Average temperature Pressure Absolute pressure, min/avg/max pressure Differential Pressure Standard Advanced Average Diff. Pressure Min/avg/max diff. pressure Acceleration Professional Inclination Rotation Norm acceleration Average acceleration (3 charts; x,y,z) Min/avg/max acceleration (3 charts; x,y,z) Pipeline Data Logger 14 |
|