1. Catalogs
  2. Emerson Automation Solutions - ROSEMOUNT
  3. Installation & Calibration Equipment

Installation & Calibration Equipment

Installation & Calibration Equipment
1 / 48 PagesView full catalog

Installation & Calibration Equipment

Product catalog summary
Overview: Emerson Process Management offers a variety of Rosemount Analytical accessories for sensor and instrument mounting across industries like chemical, food and beverage, and water treatment. The brochure covers mounting tees, ball valve kits, and configurations for conductivity, pH, ORP, and amperometric sensors.
Mounting Recommendations: Best practices include ensuring sensors are fully submerged, using pipe tape to prevent leaks, and avoiding over-tightening. Specific orientations are advised for different sensor types to ensure accurate measurements.
Insertion Sensor Mounting: Discusses in-line tees, low flow cells, handrail mounting, floating balls, and other adapters for easy sensor insertion and removal, with configurations for different sensor types.
Retraction Assemblies: Features ball valve kits and assemblies for high-pressure environments, allowing sensor maintenance without process interruption.
Instrument Mounting: Describes mounting brackets for wall, pipe, or panel installations, ensuring secure and accessible instrument placement.
Wiring Accessories: Covers best practices for cable management, including junction boxes and extension cables, to protect against moisture and ensure reliable connections.
Calibration Accessories: Details pH buffer solutions, conductivity standards, and calibration units to maintain sensor accuracy.
Flow Accessories: Includes rotameters and flow controllers to manage sample flow rates, crucial for accurate sensor readings.
Special Parts and Assemblies: Custom panels with sensors and instruments for specific applications, ensuring ease of installation and operation.
Certificates: Information on calibration and material certificates for sensors and chemicals, ensuring compliance and traceability.
Specifications: Detailed specifications for dissolved oxygen sensors, particularly the 499ADO model, including optional accessories like the Jet Spray Cleaner and various mounting assemblies. Sensors require continuous flow for accurate measurements and are unsuitable for standing liquids. Specifications include materials, temperature range, and pressure limits.
Procedures: Installation procedures emphasize correct sensor mounting for accurate readings, with visual aids showing correct and incorrect installations. Describes handrail mounting assemblies and floating ball systems for maintaining sensor positioning in varying water levels.
Standards and Recommendations: Recommends specific adapters and connectors for different sensor models to ensure compatibility and ease of installation. Advises on using retraction assemblies for safe sensor removal without depressurizing systems.
Key Components and Accessories:
  • Floating Ball System: Keeps sensors at a fixed depth, accommodating sensors with 1-inch back-facing threads.
  • Jet Spray Cleaner: Cleans sensors by directing a spray of cleaning fluid, suitable for tank or basin installations.
  • Mounting Adapters: Various adapters for threaded and submersion connections, ensuring secure sensor installation.
  • Retraction Assemblies: Allow sensors to be inserted or removed without system depressurization, with adjustable insertion depths.
Figures and Illustrations: Includes numerous figures illustrating the installation and use of sensors and accessories, such as correct sensor mounting, floating ball systems assembly, and jet spray cleaners use.
Critical Information: Continuous flow is necessary for accurate sensor operation. Proper installation is crucial to avoid incorrect readings. The document provides part numbers and descriptions for ordering components and accessories.
Retraction Assemblies: Designed for Model 228 toroidal conductivity sensors and adaptable for certain pH and contacting conductivity sensors. Two types: mechanical (PN 23311-00) and manual (PN 23311-01), with flush ports for cleaning before removal. Requires a 1-1/2" full port ball valve (PN 9340065).
PASVE Rotary Retraction Valve: Used for mounting and servicing pH sensors, allowing cleaning and calibration without halting the process. Available for direct welding onto pipes or tanks and with flanged connections, supporting various pH sensors at temperatures up to 482°F and pressures up to 570 psig.
Instrument Mounting: Includes kits for pipe or wall mounting of Rosemount Analytical instruments, compatible with several models. Mounting brackets available in carbon steel or 316 SST.
Wiring Accessories: Junction boxes and cables for extending sensor connections, with a recommended maximum distance of 200 ft between sensors and instruments. Wireless solutions available for remote installations.
Remote Junction Boxes: Allow extended sensor cable runs, suitable for indoor and outdoor use. PN 23550-00 compatible with most sensors, PN 23555-00 specifically for pH and ORP sensors with an integral preamplifier.
VP Connector Cables: Various extension and connector cables for EMI protection, used with sensors featuring VP quick disconnect fittings.
Overview: Detailed specifications and guidelines for sensor cables, calibration accessories, flow accessories, and special parts used in analytical instruments, particularly by Rosemount Analytical.
1. Sensor Cables:
  • VP6 Cable: Compatible with multiple sensors, features a PVC jacket, maximum diameter of 0.31 inches, and temperature range of -40°C to 105°C.
  • VP8 Cable: Designed for pH and ORP sensors, available in various lengths.
  • Extension Cables: Available in prepped and unprepped forms, with recommendations for factory-prepped cables.
2. Calibration Accessories:
  • Conductivity Validation Unit (CVU): For calibrating conductivity sensors, available in two versions.
  • Calibration Standards: Offers pH buffer solutions and conductivity standards in various sizes and color codes.
  • Bench Top Calibrator: For convenient calibration of SMART pH sensors in a laboratory setting.
3. Flow Accessories:
  • Rotameters: Measure and control flow in sidestream samples.
  • Constant Head Flow Controller: Provides steady flow control using gravity, not recommended for certain conductivity sensors.
4. Special Parts and Assemblies: Custom modifications and assemblies for specific customer requirements.
Special Systems and Assemblies: Describes custom systems and assemblies involving Hoffman enclosures and instruments, customizable for multiple sensors and instruments.
Certificates and Calibration: Outlines different levels of calibration certificates, including basic, electronic calibration test data, and loop calibration compliant with NIST standards. Other certificates include hazardous area certificates and material certificates.
Product Index: Comprehensive index lists part numbers and descriptions, including tags, adapters, junction boxes, extension cables, pH buffers, rotameters, and more.
Contact Information: Provides contact details for various Emerson Process Management offices worldwide.
See more

Catalog excerpts

Installation & Calibration Equipment-1

Installation & Calibration Equipment Sensor & Instrument Mounting, Accessories, Systems and More Visualize > Analyze > Optimize ROSEMOUNT EMERSON Analytical Process Management

 Open the catalog to page 1
Installation & Calibration Equipment-2

INSTALLATION & CALIBRATION EQUIPMENT Emerson Process Management offers a variety of Rosemount Analytical accessories to fit many requirements. This brochure includes mounting tees, ball valve kits, and other configurations used for mounting conductivity, pH, ORP and amperometric (dissolved oxygen, chlorine, and ozone) sensors and instruments. Please note that each mounting accessory is only valid for the stated sensor(s). Also included is information on instrument mounting, cables, junction boxes and various chemicals. The accessories in this brochure can be used in a wide variety of applications...

 Open the catalog to page 2
Installation & Calibration Equipment-3

CHOOSING THE RIGHT MOUNTING SOLUTION VP CONNECTOR SHOWN; SENSORS ARE ALSO AVAILABLE WITH INTEGRAL CABLE PROCESS END (FRONT END) THREADS, CLOSEST TO SENSING/MEASURING END OF THE SENSOR BACK END PROCESS THREADS, CLOSEST TO CABLE OR VP CONNECTOR Figure 1. The 3900 general purpose pH sensor is offered with 1 inch MNPT threads in two locations: one on the process end and one on the cable end. It also has a 3/4” MNPT process end thread. Understanding sensor process connections: process connector (sold separately) to allow variable insertion depths for the sensor and easy sensor removal without twisting...

 Open the catalog to page 3
Installation & Calibration Equipment-4

MOUNTING RECOMMENDATIONS FOR SENSORS tees and flow cells: > To prevent leakage, wrap the sensor threads with pipe tape before inserting into its mounting. > Do not over tighten the sensorwhen installing. Hand tighten the sensor, and then tighten with a wrench. > The electrodes must be completely submerged in the process liquid to measure properly Install Sensor Figure 4. pH sensor recommended mounting orienta- tion. pH sensors should be mounted at least 10° from the horizontal to ensure correct measurement. Sensors can also be mounted vertically. Install sensor within 45° of vertical Figure 5....

 Open the catalog to page 4
Installation & Calibration Equipment-5

MOUNTING RECOMMENDATIONS FOR SENSORS Measured Conductivity Conductivity (toroidal) sensors should be kept at a far enough distance between sensor and pipe wall to ensure the pipe wall does not interfere with the reading. If clearance is too small, the sensor should be calibrated while in the pipe. The sensor should be completely submerged in liquid. Mounting the sensor in a vertical pipe run with the flow from bottom to top is best. If the sensor must be mounted in a horizontal pipe run, orient the sensor in the 3 o’clock or 9 o’clock position. Metal Pipe True Conductivity Plastic Pipe 3/4 to...

 Open the catalog to page 5
Installation & Calibration Equipment-6

INSERTION SENSOR MOUNTING The mounting parts contained in this section include inline tees, low flow cells, a handrail mounting assembly, a floating ball system, a jet spray cleaner, mounting adapters, and process connectors. The in-line tees are offered in various configurations to assist in easy sensor insertion and removal without twisting cables. The low flow cells are available for sidestream samples with 1/4" OD tubing. The handrail mounting assembly is available with all the parts needed to install a sensor into a pond MEASUREMENT TYPE or basin; the jet-spray cleaner can be used with this...

 Open the catalog to page 6
Installation & Calibration Equipment-7

IN-LINE TEES These versatile in-line tees can be used with Rosemount Analytical pH, ORP, conductivity, dissolved oxygen, ozone, and chlorine sensors having 1-inch process connections. Compatible sensor models are listed in the table below. Tees can be installed directly in process piping or in slip streams. PN 23567-00 and PN 91524003, -04, and -05 have union fittings that allow the sensor In-Line Tees to be removed without the need to unscrew it, thus eliminating the possibility of the cable becoming twisted and damaged. Tees are offered in PVC and CPVC and can connect to ¾, 1, and 1 ½ inch...

 Open the catalog to page 7
Installation & Calibration Equipment-8

IN-LINE TEES Tees with union adapters offer quick and easy access and eliminate damage from cable twisting. Figure 17. 2 in. tee with ¾, 1, or 1½ in. threaded process connections (PN 915240-03, -04, -05 respectively) shown with a Model 499A amperometric sensor. The tee assembly is offered with a sensor mounting adapter that allows the user to remove the sensor without twisting the cable. Figure 16. Sensor tip in process stream flow path. Figure 18. PERpH-X 3500VP pH sensor in PN 915240-03 Tee Figure 14. 1½ in. tee with 1½ in. socket process connection (PN 23567-00) shown with a Model 499A amperometric...

 Open the catalog to page 8
Installation & Calibration Equipment-9

Emerson offers a variety of low flow cells for sidestream applications where it is impractical to divert a large volume of sample, particularly if the sample must be sent to waste. Choose a transparent plastic or stainless steel body—both have ¼ inch FPT process connections. Plastic flow cells PN 24091-00, -01, and -02 are also supplied with ¼ inch MPT to ¼ inch OD tubing fittings Process Connection Wetted Materials and have a union connection that allows easy removal of the sensor. Valved rotameters are also available (see page 41) to adjust and measure sample flow in sidestream installations....

 Open the catalog to page 9
Installation & Calibration Equipment-10

HANDRAIL MOUNTING Use a handrail mounting assembly whenever a pH, ORP, or dissolved oxygen sensor must be installed in a tank, aeration basin, pond, or open channel. Two versions are available. PN 11275-01 consists of a 13-ft (4.0-m) long PVC pipe with a 45° bend about two feet (0.6 m) from the lower end where the sensor is connected. The angle allows bubbles to slide off the sensor. Clamps attach the pipe to a frame that can be bolted to a handrail. The pipe insertion depth is adjustable. The HRMS consists of a 1½ inch pipe clamp held by a clevis and pin assembly, which can be attached to a...

 Open the catalog to page 10
Installation & Calibration Equipment-11

HANDRAIL MOUNTING ASSEMBLY SWEEP PIPE WITH 1 INCH FNPT ADAPTER REGUL ARY CHECK TO MAKE SURE CONNECTIONS ARE WATER TIGHT ZnCAN BE ANY CONVENIENT DIMENSION Figure 28. Handrail Mounting Assembly (PN 11275-01) shown with Model 499A Dissolved Oxygen Sensor.

 Open the catalog to page 11

All Emerson Automation Solutions - ROSEMOUNT catalogs and technical brochures

  1. FRL Accessories

    14  Pages

  2. TankRadar Pro

    32  Pages

  3. Roxar PTPT15K

    2  Pages

  4. SW-300

    4  Pages

  5. DL8000

    12  Pages

  6. AMS Suite

    16  Pages

  7. Line Card

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.