Single probe Double Layer Detection System for solar wafers (Solar sensors WF12IG453S)
4Pages

{{requestButtons}}

Catalog excerpts

Single probe Double Layer Detection System for solar wafers (Solar sensors WF12IG453S) - 1

SINGLE PROBE DOUBLE LAYER DETECTION SYSTEM for crystalline Solar Wafer DOUBLE SHEET DETECTOR A100 • Double Layer Detection for crystalline Solar Wafers • Eddy current measurement principle • Very fast response time - less than 20 ms • Analog output for connection to PLC

Open the catalog to page 1
Single probe Double Layer Detection System for solar wafers (Solar sensors WF12IG453S) - 2

Important Notes: The sensor WF12IG453S was specifically developed for double layer detection applications of crystalline solar wafers. The following requirements must be fulfilled during the measurement: 1. No electrically conductive material at the circumference of the sensor body of 26 mm diameter (1 in.) The air gap between sensor face and solar wafers surface must be kept constant during measurement. The ideal air gap is .5 mm +/- .2 mm, for other sensor gaps refer to „Typical sensor data WF12IG453S“ Typical values at 25°C (70°F) Output voltage depending of cell type (Air gap 0.5 mm)...

Open the catalog to page 2
Single probe Double Layer Detection System for solar wafers (Solar sensors WF12IG453S) - 3

Note: The cell type is not a standardized classification. Cell type denotes the combined influence of the silicon thickness, backside surface coating and bus conductor. This influence leads to differing output voltage behavior. Important: Because the output voltage behavior depends on the wafer type, a teaching procedure is necessary. Output voltage depending of air gap (Cell type B) Output voltage[V] Air gap (0.1 mm) Typical sensor data WF12IG453S Air gap region without restriction Absolute largest air gap1 Air gap variation during the measurement ... Air gap 0.0 mm ... Air gap 1.0 mm ......

Open the catalog to page 3
Single probe Double Layer Detection System for solar wafers (Solar sensors WF12IG453S) - 4

Flange plug M12 Power supply / Signal • Power supply ORDER INFORMATION Control unit Part name Control unit in aluminium enclosure, operating voltage 20 .. 28 VDC Part name Double-Layer Sensor M12x1, with Plug connection, incl. 2 Plastic nut Cable, Straight male and female, for connection to the control unit Part name Parte name Cable, Straight male and female, for connection to the control unit Cable, one end with straight, the other for terminal connection Cable, one end with straight, the other for terminal connection Standard length of cable is 5 m, larger lengths upon request Comment...

Open the catalog to page 4

All ROLAND ELECTRONIC catalogs and technical brochures

  1. NS9N-AAD-SC

    4 Pages

  2. ECT40

    4 Pages

  3. C100

    4 Pages

  4. XA100

    4 Pages

  5. SND8S

    4 Pages

  6. NS9SC

    4 Pages