Catalog excerpts
Eddy Current Inspection System ECT40 System for fault inspection of metallic semiproducts such as tubes, coils, wires and cables by eddy current measurement. ● Absolute and differential channel ● Frequencies: 1 kHz - 2 MHz ● Real-time communication of measurement module with the evaluation computer via Ethernet ● I/O interface for automation ● Evaluation computer for visualization and operation of the measurement channels THE ROLAND PLUS ► Compact design ► Full HD graphics
Open the catalog to page 1EDDY CURRENT INSPECTION SYSTEM ECT40 The ECT40 serves the fault inspection of metallic semiproducts such as tubes, coils, wires, cables and bars. It has been specifically developed for the use in the quality control area. The standard DIN EN ISO 15548-1 was considered in the conception of the system. Focussed applications of the system are inspection of surface, volume or subareas like weld seam, using one or more sensor coils. In the field of eddy current testing, the following inspection standards are usually applied: ASTM, API, BS, JIS, ETTC, ENEL, DIN, EN, ISO. In order to provide the...
Open the catalog to page 2EDDY CURRENT INSPECTION SYSTEM ECT40 The eddy current measurement module is accommodated separately from the evaluation computer ECT40-PC and connected via Ethernet cable. The dual channel module works phase synchronous with a common transmitter. The module ECT40-IO-ADAP serves as interface to the PLC. Fieldbus systems are under preparation. The visualization of operations is performed with a supplied software for Windows OS, as well as the operation of the measurement channel. The software communicates with the measuring module via Ethernet. The whole administration and the complete log is...
Open the catalog to page 3EDDY CURRENT INSPECTION SYSTEM ECT40 Technical Data Evaluation Signal: Thresholds: Sample rate: Other module data Voltage supply: Power consumption: Ambient temperature: Protection class: Control signals: (Extract) Data interface: Sensor interface: Connections: CE conformity: Circle, sector, double sector, 3 10 kHz per channel 24 VDC +/-5% approx. 25 W ( 2 channel) +5°C to +40°C (operation) IP65 Ready for operation, measurement start, fault / sorting, marking Ethernet 100 Mbit/s Differential / Absolute coil with separate transmitter and receiver Pluggable at front side EN 61000-6-2:2005-08,...
Open the catalog to page 4All ROLAND ELECTRONIC catalogs and technical brochures
-
NS9N-AAD-SC
4 Pages
-
Thickness Gauging
38 Pages
-
Angle Control Unit SIS-ACU
4 Pages
-
SHX42 Sensor bracket
4 Pages
-
Remote Service Box RSB
2 Pages
-
SND40 for tubes
4 Pages
-
SND40 for coils
4 Pages
-
SIS Calibrator
4 Pages
-
C100
4 Pages
-
XA100
4 Pages
-
SND8S
4 Pages
-
NS9SC
4 Pages
-
DOUBLE SHEET DETECTOR C100-S
4 Pages