Double Sheet Detection System A100 Single probe Double Sheet Detection System for ferrous materials THE ROLAND PLUS ► Teach-In ► Clear-Type-Display ► 3 Outputs ● Single probe permanent-magnetic sensors ● Ferrous material 0.04 - 4 mm (0.0015 - 0.16 in) thickness (single sheet) ● Easy set-up by key operation or via control input ● LCD display for visualization of nominal / current values, operational / error message, key allocation ● Compact enclosures - Control unit for DIN-rail mounting, protection class IP00 - Control unit for machine frame mounting, in protective enclosure, protection class IP54 The manual contains detailed security instructions These devices are NOT suitable for personnel safety applications. Never use these products as sensing devices for personnel protection. Their use as a safety device may create an unsafe condition which could lead to injury or death.

 Open the catalog to page 1

DOUBLE SHEET DETECTION SYSTEM A100 Application When feeding sheets automatically, more than one sheet can be inadvertently fed into the processing machine. This can result in damage of the machine and tools, expensive repairs and production loss. The single probe Double Sheet Detector A100 has been designed to prevent such events. Function The permanent magnetic sensors detect electronically magnetic flux changes caused by sheet interference. The magnetic flux changes are transformed into electrical signals by the sensors. These electrical signals are processed by the control unit and sent...

 Open the catalog to page 2

DOUBLE SHEET DETECTION SYSTEM A100 Technical Data A100 Supply voltage Power consumption Power / Switching indication LCD display, 16 characters each Ambient temperature Switching outputs 0-1-2 - Sheet Opto coupler outputs, output sourcing (PNP) Temperature drift of switching point Switching capacity Measurement period The minimum dwell time of the sheet on the sensor is 15 ms For DIN-rail mounting (EN50022, BS5584) / Aluminum enclosure for machine frame mounting Terminal Block / Plug connection Supply connection Enclosure HAN 3A, EMI-typw, metrical, 7-pin insert and PE Sensor socket M12,...

 Open the catalog to page 3

DOUBLE SHEET DETECTION SYSTEM A100 Abbreviated Set-up For detailed instructions refer to the Operating Manual Teach-In instructions 1. Put a sheet with nominal thickness fully onto the sensor (see connection sketch). 2. Press the SETUP key and then the NEW key, a new Teach-In procedure will then be performed. 3. The green LED (1-sheet) lights up now, the measuring value is stored. 4. Functional check: If a second sheet is placed in front of the sensor (double sheet condition), the red LED (2-sheet) lights up. If both sheets are removed, the red LED (0-sheet) lights up. ORDER INFORMATION...

 Open the catalog to page 4