| | | 5. Maintenance | | |
| | | |
| | | The level of maintenance of the clamping device determines its functionality, clamping force, accuracy and service life. Regular maintenance consists of charging the grease nipples (see illustration) with approx. 0.5 cm3 grease approximately every 8 operating hours. A non-acidic, viscous grease with MoS2 additive should be used for this purpose. | | We recommend our F90* grease in this respect. Several no-load clamping strokes should be completed after lubricating to distribute the grease applied evenly. The guides for the 3 wedge bars and 3 clamping jaws are supplied with lubricant via the grease nipples. | | |
| | | |
| | | |
| | | Blowing out: Never blow into the jaw guides or guide slots with air. | | |
| | | |
| | | Preventing maintenance work: | | |
| | | |
| | | | | | | | | | | | Check-list | Period | Procedure | Possibility of error | | | | | every 6 months | Clamping force measuring system EDS** | wear of the sealings in the cylinder lack of lubrication | | | | Wear control of the clamping set | weekly | visually | loss of torque loss of accuracy | | | | Mounting check of the clamping set parts | weekly | check screw connection | loss of torque loss of accuracy | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | * Recommended grease F90: | Id.-Nr.: | ** Recommended clamping force measuring system EDS: | Id.-Nr.: | | | | 100-g-tube | 630869 | EDS 50 compl. | 161425 | | | | 1000-g-case | 619989 | EDS 100 compl. | 161426 | | | | | | EDS 50/100 compl. | 161427 | | | | | | | | | | | |
| | | |
| | | 6. Spare parts When ordering spare parts, please quote the Ident. No. of the chuck and the item number or designation of the desired part (see page 2). - The Ident. No. will be found on the face of the chuck. | | |
| | | |
| | | | | |
| | | |
| | | | | | | | | | | | | | | | | | | |