5. Maintenance
The level of maintenance of the clamping device determines its functionality, clamping force, accuracy and service life. Regular maintenance consists of charging the grease nip­ples (see illustration) with approx. 0.5 cm3 grease approxi­mately every 8 operating hours. A non-acidic, viscous grease with MoS2 additive should be used for this purpose.
We recommend our F90* grease in this respect. Several no-load clamping strokes should be completed after lubricating to distribute the grease applied evenly. The guides for the 3 wedge bars and 3 clamping jaws are supplied with lubricant via the grease nipples.
Blowing out:
Never blow into the jaw guides or guide slots with air.
Preventing maintenance work:
Check-list
Period
Procedure
Possibility of error
Checking clamp. force
every 6 months
Clamping force measuring system EDS**
wear of the sealings in the cylinder lack of lubrication
Wear control of the clamping set
weekly
visually
loss of torque loss of accuracy
Mounting check of the clamping set parts
weekly
check screw connection
loss of torque loss of accuracy
* Recommended grease F90:
Id.-Nr.:
** Recommended clamping force measuring system EDS:
Id.-Nr.:
100-g-tube
630869
EDS 50 compl.
161425
1000-g-case
619989
EDS 100 compl.
161426
EDS 50/100 compl.
161427
6. Spare parts
When ordering spare parts, please quote the Ident. No. of the chuck and the item number or designation of the desired part (see page 2). - The Ident. No. will be found on the face of the chuck.