catalogue search
|
You may also be interested in
Quick-change chuck, Clamping device, Through-hole chuck, Dead center, Steady rest
Text version of the page
39 39
Typ GA/GI mit Greifkraftsicherung Zubehör: Schmutzabdeckung
RZP 64
Zubehör: Federnder Andrückstern
13 ±0,02
ƒO 76
M5
(3x)
6,7
43,3
10
56 ±0,02
9
25
M4 /5 tief
für Direktanschluss
(Schließen)
M5 /6 tief
Luftanschluss
(2x)
12
27
RZP 64/3-1 MAX. 40,5 ; MIN. 34,5
RZP 64/3-2 MAX. 40,5; MIN. 37,5
RZP 64/3-1 MAX. 23,5 ; MIN. 17,5
RZP 64/3-2 MAX. 20,5; MIN. 17,5
M4
(6x)
ƒO 4 H7
(2x)
Sensorhalter- ƒO 8
(3x)
32
32,5
15° 15°
120° 3x
120° 3x
ƒO 7H8
18
56,8
ƒO 64
55,8
4
RZP-64/3-1/2: 51,3
RZP-64/3-1/2 GA/GI: 64,8
32
120° 3x
RZP-64/3-1/2: 48,8
RZP-64/3-1/2 GA/GI: 62,3
2,5
4
48
MAX. 54
11
21
40
RZP 64/3-1 MAX. 23,5 ; MIN. 17,5
RZP 64/3-2 MAX. 20,5; MIN. 17,5
28 14
14
RZP 64/3-1: 21
RZP 64/3-2: 24
ƒO 5,5
ƒO 10
28,3
Hub 4
48,5
11
3x Bohrung
für Fed. Andrückstern
36,5
23
10
38
9
M5 /6 tief (1x)
für Sperrluft
ƒO 56
ƒO 64
Adapter Greifer
O-Ring
Ø4x1,5
Schlauchloser Direktanschluss
ƒO4
ƒO7
1,1
M4
Federkraft: MIN. 11N
MAX. 18N
30,8
10
M3
(3x)
ƒO 4,5
ƒO 6 h6
(6x)
ƒO 35
30°
ƒO 35
2,5
42,3
C-Nut für Magnetsensoren
9
/5 tief
für Direktanschluss
(Öffnen)
Centric gripping
RZP
Technical data RZP-64/3-1 RZP-64/3-2 RZP-64/3-1 GA RZP-64/3-2 GA RZP-64/3-1 GI RZP-64/3-2 GI
Item no. 170050 170051 170052 170053 170054 170055
Total gripping force at 6 bar N 650 1200 850 1600 900 1700
Total stroke mm 12 6 12 6 12 6
Total grip. force maintained by safety device N 200 400 200 400
Recommended workpiece weight kg 3.2 6.0 3.2 6.0 3.2 6.0
Weight kg 0.45 0.45 0.55 0.55 0.55 0.55
3-jaw centric gripper RZP-64
3 x Borehole for resilient
pressure piece Tubeless direct connection
Adapter Gripper
M5/6 deep for sealing
air connection
O-ring
C-nut for magnetic sensors
Ø 8 Sensor holder
M5/6 deep for sealing
air connection
Close
Open
Type GA/GI with gripping force
safety device
Accessories: Resilient pressure piece Accessories: Protective cover
Elasticity MIN. 11N
MAX. 18N
M4 /5 deep for air
connection
M4 /5 deep for
air connection Stroke
|