R&S®IQR I/Q Data Recorde - 1

Test & Measurement R&S®IQR I/Q Data Recorder Realtime recording and streaming of digital I/Q data

Open the catalog to page 1
R&S®IQR I/Q Data Recorde - 2

R&S®IQR I/Q Data Recorder At a glance The R&S®IQR is a high-speed recorder for recording and playing digital I/Q data streams. When used in combination with one of the many Rohde & Schwarz instruments that have the R&S®Digital I/Q Interface, the R&S®IQR can store and play data in realtime. The R&S®IQR I/Q data recorder is an ideal storage medium for I/Q data streams. It can be used, for example, for providing interference or test signals, for drive tests, for realtime storage of data when archiving RF signals, and for playing recorded I/Q signals. The I/Q data recorder is well suited for...

Open the catalog to page 2
R&S®IQR I/Q Data Recorde - 3

R&S®IQR I/Q Data Recorder Benefits and key features ❙❙ Fast R&S®Digital I/Q Interface with separate input and output ❙❙ Ethernet interfaces for communications and data exchange ❙❙ BNC sockets for trigger and synchronization signals ❙❙ Universal interfaces for PC peripherals ▷▷ page 7 Fast storage and playing of digital I/Q data in realtime ❙❙ Backup of recorded I/Q data files ❙❙ Export and import of I/Q data ❙❙ Processing of I/Q data, e.g. with MATLAB® ▷▷ page 8 ❙❙ R&S®Digital I/Q Interface ❙❙ Optimum configuration for the required bandwidths ▷▷ page 4 Numerous interfaces for data ­...

Open the catalog to page 3
R&S®IQR I/Q Data Recorde - 4

Fast storage and playing of digital I/Q data in realtime R&S®Digital I/Q Interface Many Rohde & Schwarz instruments have a digital I/Q inter­ face. The combination of different measuring instruments via the digital I/Q interface makes it possible to implement a wide variety of applications, from simple data recordings to providing complex RF test signals. The Rohde & Schwarz instruments compatible with the R&S®IQR are listed in the data sheet (PD 5214.4394.22). Digital I/Q data has real and imaginary parts, allowing the RF signal to be fully described. Key parameters are the sample rate and...

Open the catalog to page 4
R&S®IQR I/Q Data Recorde - 5

Rugged, compact I/Q data recorder with removable memory pack Rugged, compact, 3 HU, ½ 19" format The very compact R&S®IQR I/Q data recorder has only 3 HU and a ½ 19" width, so it can be integrated in a 19" rack with other similarly compact instruments, such as the R&S®TSMW universal radio network analyzer or the R&S®SFE broadcast tester. The design of the housing, such as the stainless steel frame, and the use of SSDs as the system memory make the R&S®IQR suitable for operation under extreme conditions as occur during drive tests, for example. The data memory packs are simple to remove and...

Open the catalog to page 5
R&S®IQR I/Q Data Recorde - 6

information directly Easy manual operation directly on the instrument In addition to a main settings menu, the instrument has a parameterization menu for recording and playing. The following functions can be parameterized: i Trigger definition (trigger source, trigger type) i Selection of file to be played or definition of file name i Record and play parameters Additional information such as the progress bar, sample rate, l/Q level, reference level and the names of the con- nected instruments is displayed to keep the user informed of the status before and during recording and playing....

Open the catalog to page 6
R&S®IQR I/Q Data Recorde - 7

Numerous i ­nterfaces for data ­communications and control Ethernet interfaces for communications and data exchange The two Ethernet interfaces are used for communications between the R&S®IQR and connected instruments. This includes external control of the R&S®IQR using remote desktop and SCPI commands and the ability to control connected instruments that do not have a built-in monitor, such as the R&S®TSMW or generators. In addition, I/Q data can be exported and imported via LAN. BNC sockets for trigger and synchronization signals Except for two USB interfaces on the front panel, all...

Open the catalog to page 7
R&S®IQR I/Q Data Recorde - 8

Export Configuration Source File... Dest. File... Export/Archiving Format Remaining Time Transfer Ftate Export Running Backup of recorded l/Q data files l/Q data recorded in realtime can be archived offline on cost-effective mass memories via the Ethernet and Export and import of l/Q data The R&S®IQR-K101 option allows an R&S®IQR l/Q data file in binary file format to be output to an external USB storage device such as a USB hard disk drive. The file can also be output via Ethernet for storage on an external network drive. This option also makes it possible to import individual l/Q data...

Open the catalog to page 8
R&S®IQR I/Q Data Recorde - 9

trigger concept The extensive trigger menu provides many control options to start and stop recording and playing. Depending on the trigger source, the following modes are available: Triggering on the l/Q level prevents recording of nonrelevant data Triggering on the l/Q level optimizes the start of recording, providing a type of observation mode. In conjunction with a predefined recording time (record duration), the storage requirements can be limited to the data of interest. Triggering by external signals The rising or falling slope of external signals at a user- definable BNC socket can...

Open the catalog to page 9
R&S®IQR I/Q Data Recorde - 10

Simultaneous recording and playing of several spectra Multiplexing and parallel output of I/Q data streams The R&S®IQR­K105 option supports the recording and playing of multiplexed I/Q data streams of the R&S®TSMW universal radio network analyzer. As a result, up to two spectra can be transferred simultaneously via the digital I/Q interface. The simultaneously stored spectra can be transferred to a PC for further processing (R&S®IQR­K101 option) or output to two generators equipped with the R&S®Digital I/Q Interface (R&S®IQR­K107 option). Simultaneous recording and playing of multiple...

Open the catalog to page 10
R&S®IQR I/Q Data Recorde - 11

Continuous recording of position data and reference levels Recording and graphical display of position data eliminates need for video recordings Recording of GPS coordinates The ability to assign a location to the recorded spectrum is an important function for drive test applications. The R&S®IQR­K102 option allows GPS data to be trans­ ferred via USB from the R&S®TSMW GPS receiver or from the separate R&S®TSMX­PPS2 GPS receiver (see “Applications”). The time-synchronized GPS data is saved in a separate file together with the sample count, providing a clear allocation to the I/Q data...

Open the catalog to page 11

All Rohde Schwarz catalogs and technical brochures

  1. R&S®FPL1000

    20 Pages

  2. R&S®HF907

    2 Pages

  3. R&S®EVSF1000

    12 Pages

  4. R&S®UMS175

    10 Pages

  5. R&S®AVHE100

    24 Pages

  6. HM8030

    2 Pages

Archived catalogs