Test & Measurement R&S®IQR I/Q Data Recorder Realtime recording and streaming of digital I/Q data
Open the catalog to page 1R&S®IQR I/Q Data Recorder At a glance The R&S®IQR is a high-speed recorder for recording and playing digital I/Q data streams. When used in combination with one of the many Rohde & Schwarz instruments that have the R&S®Digital I/Q Interface, the R&S®IQR can store and play data in realtime. The R&S®IQR I/Q data recorder is an ideal storage medium for I/Q data streams. It can be used, for example, for providing interference or test signals, for drive tests, for realtime storage of data when archiving RF signals, and for playing recorded I/Q signals. The I/Q data recorder is well suited for...
Open the catalog to page 2R&S®IQR I/Q Data Recorder Benefits and key features ❙❙ Fast R&S®Digital I/Q Interface with separate input and output ❙❙ Ethernet interfaces for communications and data exchange ❙❙ BNC sockets for trigger and synchronization signals ❙❙ Universal interfaces for PC peripherals ▷▷ page 7 Fast storage and playing of digital I/Q data in realtime ❙❙ Backup of recorded I/Q data files ❙❙ Export and import of I/Q data ❙❙ Processing of I/Q data, e.g. with MATLAB® ▷▷ page 8 ❙❙ R&S®Digital I/Q Interface ❙❙ Optimum configuration for the required bandwidths ▷▷ page 4 Numerous interfaces for data ...
Open the catalog to page 3Fast storage and playing of digital I/Q data in realtime R&S®Digital I/Q Interface Many Rohde & Schwarz instruments have a digital I/Q inter face. The combination of different measuring instruments via the digital I/Q interface makes it possible to implement a wide variety of applications, from simple data recordings to providing complex RF test signals. The Rohde & Schwarz instruments compatible with the R&S®IQR are listed in the data sheet (PD 5214.4394.22). Digital I/Q data has real and imaginary parts, allowing the RF signal to be fully described. Key parameters are the sample rate and...
Open the catalog to page 4Rugged, compact I/Q data recorder with removable memory pack Rugged, compact, 3 HU, ½ 19" format The very compact R&S®IQR I/Q data recorder has only 3 HU and a ½ 19" width, so it can be integrated in a 19" rack with other similarly compact instruments, such as the R&S®TSMW universal radio network analyzer or the R&S®SFE broadcast tester. The design of the housing, such as the stainless steel frame, and the use of SSDs as the system memory make the R&S®IQR suitable for operation under extreme conditions as occur during drive tests, for example. The data memory packs are simple to remove and...
Open the catalog to page 5information directly Easy manual operation directly on the instrument In addition to a main settings menu, the instrument has a parameterization menu for recording and playing. The following functions can be parameterized: i Trigger definition (trigger source, trigger type) i Selection of file to be played or definition of file name i Record and play parameters Additional information such as the progress bar, sample rate, l/Q level, reference level and the names of the con- nected instruments is displayed to keep the user informed of the status before and during recording and playing....
Open the catalog to page 6Numerous i nterfaces for data communications and control Ethernet interfaces for communications and data exchange The two Ethernet interfaces are used for communications between the R&S®IQR and connected instruments. This includes external control of the R&S®IQR using remote desktop and SCPI commands and the ability to control connected instruments that do not have a built-in monitor, such as the R&S®TSMW or generators. In addition, I/Q data can be exported and imported via LAN. BNC sockets for trigger and synchronization signals Except for two USB interfaces on the front panel, all...
Open the catalog to page 7Export Configuration Source File... Dest. File... Export/Archiving Format Remaining Time Transfer Ftate Export Running Backup of recorded l/Q data files l/Q data recorded in realtime can be archived offline on cost-effective mass memories via the Ethernet and Export and import of l/Q data The R&S®IQR-K101 option allows an R&S®IQR l/Q data file in binary file format to be output to an external USB storage device such as a USB hard disk drive. The file can also be output via Ethernet for storage on an external network drive. This option also makes it possible to import individual l/Q data...
Open the catalog to page 8trigger concept The extensive trigger menu provides many control options to start and stop recording and playing. Depending on the trigger source, the following modes are available: Triggering on the l/Q level prevents recording of nonrelevant data Triggering on the l/Q level optimizes the start of recording, providing a type of observation mode. In conjunction with a predefined recording time (record duration), the storage requirements can be limited to the data of interest. Triggering by external signals The rising or falling slope of external signals at a user- definable BNC socket can...
Open the catalog to page 9Simultaneous recording and playing of several spectra Multiplexing and parallel output of I/Q data streams The R&S®IQRK105 option supports the recording and playing of multiplexed I/Q data streams of the R&S®TSMW universal radio network analyzer. As a result, up to two spectra can be transferred simultaneously via the digital I/Q interface. The simultaneously stored spectra can be transferred to a PC for further processing (R&S®IQRK101 option) or output to two generators equipped with the R&S®Digital I/Q Interface (R&S®IQRK107 option). Simultaneous recording and playing of multiple...
Open the catalog to page 10Continuous recording of position data and reference levels Recording and graphical display of position data eliminates need for video recordings Recording of GPS coordinates The ability to assign a location to the recorded spectrum is an important function for drive test applications. The R&S®IQRK102 option allows GPS data to be trans ferred via USB from the R&S®TSMW GPS receiver or from the separate R&S®TSMXPPS2 GPS receiver (see “Applications”). The time-synchronized GPS data is saved in a separate file together with the sample count, providing a clear allocation to the I/Q data...
Open the catalog to page 11All Rohde Schwarz catalogs and technical brochures
-
R&S®FPC Spectrum analyzer
16 Pages
-
R&S®ZNL vector network analyzer
18 Pages
-
R&S®MXO 4 Oscilloscope
40 Pages
-
R&S®RTE1000 oscilloscope
40 Pages
-
R&S®FPL1000
20 Pages
-
R&S®ZNA vector network analyzers
52 Pages
-
R&S®HF907
2 Pages
-
R&S®RO129 Antenna Rotator
6 Pages
-
R&S®PR100 Portable Receiver
30 Pages
-
R&S®ETC Compact TV Analyzer
12 Pages
-
R&S®RSC Step Attenuator
10 Pages
-
R&S®RTA4000 Oscilloscope
22 Pages
-
R&S®NRP Power Meter Family
40 Pages
-
R&S®EVSF1000
12 Pages
-
R&S®UMS175
10 Pages
-
R&S®AVHE100
24 Pages
-
HM8030
2 Pages
-
R&S®HMC8015 Power Analyzer
10 Pages
-
R&S®HM8118 LCR-Bridge
2 Pages
-
Digital Multimeter HMC8012
3 Pages
-
Mobile network testing solutions
20 Pages
-
Value Instruments Catalog
69 Pages
-
Test & Measurement Catalog 2016
266 Pages
-
R&S®BBA150 Broadband Amplifier
16 Pages
-
R&S®UPZ Audio Switcher
6 Pages
-
R&S®SMZ Frequency Multiplier
8 Pages
-
Test & Measurement Catalog 2013/2014
214 Pages
-
R&S®CMW-CU Control Unit
6 Pages
-
R&S®FSQ Signal Analyzer
14 Pages
-
R&S®FSU Spectrum Analyzer
16 Pages
-
R&S®RTE-B1 Mixed Signal, 400 MHz
26 Pages
-
R&S®RTO Digital Oscilloscopes
32 Pages
-
R&S®ZVB Vector Network Analyzers
20 Pages
-
R&S®CMA180 Radio Test Set
16 Pages
-
R&S®CBT/CBT32 Bluetooth® Tester
20 Pages
-
R&S®UPV Audio Analyzer
24 Pages
-
R&S®RTE Digital Oscilloscope
26 Pages
-
R&S®TSMX-PPS2 GPS Module
4 Pages
-
R&S®CMW500 Platform overview
20 Pages
-
R&S®EM010 VXI HF Receiver
10 Pages
-
EMC Precompliance Solutions
79 Pages
-
UMS120 Monitoring Syste
8 Pages
Archived catalogs
-
Network Operators Catalog
18 Pages
-
Broadcasting Catalog
144 Pages
-
Secure communication Catalog
274 Pages
-
T & M Product Catalog
146 Pages
-
R&S®RF Step Attenuators
2 Pages
-
Q8384 Optical Spectrum Analyzer
10 Pages
-
R&S®NRP Power Meter
22 Pages
-
Audio Analyzers ¸UP 300/¸UP 350
16 Pages
-
R&S®ZVL Vector Network Analyzers
14 Pages
-
SMU200A Flyer
2 Pages
-
SMU200A Vector Signal Generator
44 Pages
-
R&S®EVS300 ILS/VOR Analyzer
12 Pages
-
WiMAX Communication Tester
16 Pages