video corpo

R&S®CMA180 Radio Test Set Specifications
28Pages

{{requestButtons}}

Catalog excerpts

R&S®CMA180 Radio Test Set Specifications - 1

Test & Measurement R&S®CMA180 Radio Test Set Specifications

Open the catalog to page 1
R&S®CMA180 Radio Test Set Specifications - 2

Rohde & Schwarz R&S CMA180 Radio Test Se

Open the catalog to page 2
R&S®CMA180 Radio Test Set Specifications - 3

Rohde & Schwarz R&S CMA180 Radio

Open the catalog to page 3
R&S®CMA180 Radio Test Set Specifications - 4

Definitions General Product data applies under the following conditions: • • • • Three hours storage at ambient temperature followed by 15 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <, ≤, >, ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing...

Open the catalog to page 4
R&S®CMA180 Radio Test Set Specifications - 5

The R&S CMA180 radio test set is a compact tester for analog radios. It is equipped with a high-performance RF generator, RF analyzer, AF generator and AF analyzer and features advanced interfaces. Its future-ready hardware concept also permits testing of digital radios. An arbitrary waveform generator (ARB) allows the generation of complex RF signals. Designed for high performance, ® usability and portability, the R&S CMA180 is the right choice for development, production and service applications. Rohde & Schwarz R&S CMA180 Radio Test Set

Open the catalog to page 5
R&S®CMA180 Radio Test Set Specifications - 6

General technical specifications RF generator Frequency range Frequency resolution Frequency uncertainty 0.1 MHz to 3000 MHz 1 Hz same as timebase + frequency resolution Output level range RF COM with high-power attenuator RF COM without high-power attenuator Output level uncertainty in temperature range from +20 °C to +35 °C, no overranging output level > –120 dBm 0.1 MHz to 1 MHz 1 MHz to 2000 MHz 2000 MHz to 2700 MHz 2700 MHz to 3000 MHz output level > –112 dBm 0.1 MHz to 1 MHz 1 MHz to 2000 MHz 2000 MHz to 2700 MHz 2700 MHz to 3000 MHz 0.1 MHz to 30 MHz continuous wave (CW) peak...

Open the catalog to page 6
R&S®CMA180 Radio Test Set Specifications - 7

Output level uncertainty RF COM Output level linearity with fixed RF output attenuator setting (digital gain) RF COM Output level resolution Output level repeatability Output level setting range RF COM with high-power attenuator RF COM without high-power attenuator RF OUT RF power overload protection RF COM with high-power attenuator ("RF COM connector attenuation" in setup menu) RF COM without high-power attenuator ("RF COM connector attenuation" in setup menu) RF IN in temperature range from 0 °C to 1 +50 °C , no overranging output level > –120 dBm 0.1 MHz to 1 MHz 1 MHz to 2000 MHz 2000...

Open the catalog to page 7
R&S®CMA180 Radio Test Set Specifications - 8

Version 04.00, May 2015 Attenuation of second harmonics RF COM with high-power attenuator RF COM without high-power attenuator RF OUT Attenuation of third harmonics RF COM with high-power attenuator RF COM without high-power attenuator RF OUT Attenuation of nonharmonics RF COM, RF OUT, with/without high-power attenuator Nonharmonics, absolute RF COM with high-power attenuator Phase noise harmonics of 24.576 MHz and 25 MHz, except 175 MHz, 225 MHz, 275 MHz, 325 MHz, 375 MHz 175 MHz, 225 MHz, 275 MHz, 325 MHz, 375 MHz harmonics of 800 MHz 920.3125 MHz and 1840.625 MHz 2760.9375 MHz single...

Open the catalog to page 8
R&S®CMA180 Radio Test Set Specifications - 9

Modulation Modulation Amplitude modulation Source Modulation frequency Modulation distortion range resolution uncertainty, internal source uncertainty, external source range resolution CCITT-weighted internal modulation source, external AF1 IN, AF2 IN, external SPDIF IN 0 % to 100 % 0.1 % <1% <3% 0 Hz to 21 kHz 0.1 Hz <1% range resolution uncertainty, internal source uncertainty, external source range, internal modulation generator CCITT-weighted internal modulation source, external AF1 IN, AF2 IN, external SPDIF IN 0 Hz to 100 kHz 1 Hz <1% <3% 0 Hz to 21 kHz <1% range resolution...

Open the catalog to page 9
R&S®CMA180 Radio Test Set Specifications - 10

Version 04.00, May 2015 Multitone frequency range Noise 1 to 20 selectable tones with individual frequencies and levels 0 Hz to 21 kHz signal composite with flat frequency response 0 Hz to 21 kHz Modulation source: arbitrary waveform generator (ARB) (R&S®CMA-B110B option) Memory size Word length Sample length Sample rate Maximum possible RF bandwidth I Q marker with 4-bit marker minimum maximum depending on arbitrary waveform file Trigger Trigger sources Delay Repetition external TRIG IN 0 s to 100 s single, continuous Interferer Interferer Delta frequency range Delta level range Modulation...

Open the catalog to page 10
R&S®CMA180 Radio Test Set Specifications - 11

Version 04.00, May 2015 Harmonic response RF COM Spurious response Inherent spurious response Phase noise Dynamic range RF COM with high-power attenuator RF COM without high-power attenuator second harmonic fin = 1 MHz to 1000 MHz, fselected = 2 MHz to 2000 MHz, input power near expected nominal power setting fin = 1000 MHz to 1500 MHz, fselected = 2000 MHz to 3000 MHz, input power near expected nominal power setting third harmonic fin = 1 MHz to 666.7 MHz, fselected = 3 MHz to 2000 MHz, input power near expected nominal power setting fin = 666.7 MHz to 1000 MHz, fselected = 2000 MHz to...

Open the catalog to page 11
R&S®CMA180 Radio Test Set Specifications - 12

Power meter TX test, expert test Frequency range Frequency resolution Measurement modes Resolution bandwidths Expected nominal power setting range Measurement control Level range RF COM with high-power attenuator RF COM without high-power attenuator measurement timeout repetition statistic measurement length step length 0.1 MHz to 1 MHz continuous wave (CW) peak envelope power (PEP) 1 MHz to 30 MHz continuous wave (CW) peak envelope power (PEP) 30 MHz to 2000 MHz continuous wave (CW) peak envelope power (PEP) 2000 MHz to 3000 MHz continuous wave (CW) peak envelope power (PEP) 0.1 MHz to 1...

Open the catalog to page 12
R&S®CMA180 Radio Test Set Specifications - 13

Version 04.00, May 2015 Level uncertainty RF COM Level uncertainty RF COM with high-power attenuator Level resolution Level repeatability Level linearity, with fixed expected nominal power setting RF COM in temperature range from +20 °C to +35 °C, no overranging 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz 2000 MHz to 3000 MHz 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz 2000 MHz to 3000 MHz in temperature range from 0 °C to 3 +50 °C , no overranging 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz 2000 MHz to 3000 MHz 0.1 MHz to 1 MHz 1 MHz to 30 MHz 30 MHz to 2000 MHz...