| | | Safety Isolation System | |
| | | |
| | | ElectroGuard™ Optional Features (continued) | | |
| | | |
| | | Expansion Module (Can be ordered separately): For applications requiring more than the maximum allowable Remote Lockout Stations, or total wire lengths longer than those permitted with the Remote Lockout Stations. Expansion Modules are available in 4 or 10 port configurations. E ach E xpansion Module is wired to a port on the Control Module, and takes the connection port that would normally accommodate a Remote Lockout Station (see page 12-18 to determine if an Expansion Module is required due to wire length considerations). The 23A through 85A systems will accommodate connection of a maximum of 4 Expansion Modules, and the 110A through 1200A systems will accommodate connection of a maximum of 6 Expansion Modules. Certain ampere size Safety Isolation System Power Panels can accommodate either 1 or 2 Expansion Modules installed internally. In all other instances the Expansion Module(s) must be located external to the Safety Isolation System in a suitably rated enclosure. | | N ote: The time delay feature affects all input devices wired to the Expansion Module. For Expansion Module(s) Factory Installed: Add One of the Following Catalogue Number Strings to the Safety Isolation System Catalogue Number: | | |
| | | |
| | | | | | | | | | | N umber of Expansion Modules | Number of Ports per Expansion Module | Catalogue N umber String O | | | | One (available on Bulletin 2031, 2032, or 2033, 110A-1200A Systems only) | 4 | -1EUF | | | | 4 w/time delay | -1EU FTDA | | | | 10 | -1EUT | | | | 10 w/time delay | -1EUTTDA | | | | Two (available on 630A - 1200A Bulletin 2032 or 2033 Systems only) | 4 | -2EUF | | | | 4 w/time delay | -2EU FTDA | | | | 10 | -2EUT | | | | 10 w/time delay | -2EUTTDA | | | | | | | | | | |
| | | |
| | | O e.g Catalogue N umber 2032T-A 0630jB-30L becomes Catalogue N umber 2032T-A 0630jB-30L-2EU T to indicate a 630A Safety Isolation System that indudes2 internally installed 10 port Ecpanson Moduleswithout the time delay feature. Open Type Expansion Module for Field Addition | | |
| | | |
| | | | | | | | | | Ampere Size of Safety Isolation System | Internal Provisions to Accommodate Expansion Modules | | | | 23A - 85A | None | | | | 110A - 420A | Provisions to accept one (1) Expansion Module (Bulletins 2031, 2032 or 2033) | | | | 630A - 1200A | Provisions to accept up to two (2) Expansion Modulesin Bulletin 2032 or 2033 combination systems, or one (1) Expansion Module in Bulletin 2031 non combination systems. | | | | | | | | | |
| | | |
| | | | | | | | | | | Open Type © | | | | Description | Catalogue Number | | | | 4 port | 2030-EUNF | | | | 4 port w/ time delay | 2030-EUNF-1TDA | | | | 10 port | 2030-EUNT | | | | 10 port w/time delay | 2030-EUNT-1TDA | | | | | | | | | |
| | | |
| | | © Requires user supplied enclosure if not installed in the Safety Isolation System Power Panel. © To order the Status Communication to a remote PLC option installed in an enclosed Expanson Module, add one of the followingCatalogue Strings to the Expansion Module Catalogue Number: | | |
| | | |
| | | Expansion Modules may be ordered with an adustable time delay feature (1-30 seconds) in order to allow time for the machine operator to shut-down drives or other equipment that requires a controlled stop after a Remote Lockout Station has been switched to the "Off " position. Consult your Rockwell Automation sales office for other time settings. Enclosed Expansion Modules are available with optional "Flex" modules to provide status communication to a remote PLC. Communication can be via DeviceNet or Remote I /O. N ote: The status communication option allows a remote PLC to receive status signals from the Expansion Module. The Expansion Module does not accept input signals from DeviceNet or Remote I/O. | | |
| | | |
| | | | | | | | | | | Communication | Number of I/O | Catalogue | | | | Platform | Points | Number String G | | | | Remote I/O | 16 points | -1COM | | | | DeviceNet | 16 points | -1DNET | | | | | | | | | | |
| | | |
| | | 0 e.g Catalogue Number 2030-BJ.F becomes Catalogue Number 2030-BJ.F-1COM to indcate a Type 12 enclosed, 4-port expansion module, with 16 points of remote I/O. | | |
| | | |
| | | |
| | | To order the optional enclosed Expansion Module for field addition for North America: | | |
| | | |
| | | | | | | | | | | | | | Catalogue N umber © | | | | Description | Type 1 Enclosure | Type12 Enclosure | Type 4 Painted Enclosure | Type 4X Stainless Steel Enclosure | | | | 4 port | 2030-EUAF | 2030-EUJF | 2030-EUFF | 2030-EUCF | | | | 4 port w/ time delay | 2030-EUAF-1TDA | 2030-EUJF-1TDA | 2030-EUFF-1TDA | 2030-EUCF-1TDA | | | | 10 port | 2030-EUAT | 2030-EUJT | 2030-EU FT | 2030-EUCT | | | | 10 port w/time delay | 2030-EUAT-1TDA | 2030-EUJT-1TDA | 2030-EUFT-1TDA | 2030-EUCT-1TDA | | | | | | | | | | | | |
| | | |
| | | To order the optional enclosed Expansion Module for field addition for outside of North America: | | |
| | | |
| | | | | | | | | | | | | Catalogue N umber © | | | | Description | IP30 Enclosure | IP54 Enclosure | IP65 Enclosure | | | | 4 port | 2030-EUPF | 2030-EUHF | 2030-EUWF | | | | 4 port w/ time delay | 2030-EUPF-1TDA | 2030-EUHF-1TDA | 2030-EUWF-1TDA | | | | 10 port | 2030-EUPT | 2030-EUHT | 2030-EUWT | | | | 10 port w/time delay | 2030-EUPT-1TDA | 2030-EUHT-1TDA | 2030-EUWT-1TDA | | | | | | | | | | | |
| | | |
| | | 12-16 | | |
| | | © Allen-Bradley | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | |