Safety Isolation System
ElectroGuard™
Optional Features (continued)
Expansion Module (Can be ordered separately):
For applications requiring more than the maximum allowable Remote Lockout Stations, or total wire lengths longer than those permitted with the Remote Lockout Stations. Expansion Modules are available in 4 or 10 port configurations. E ach E xpansion Module is wired to a port on the Control Module, and takes the connection port that would normally accommodate a Remote Lockout Station (see page 12-18 to determine if an Expansion Module is required due to wire length considerations).
The 23A through 85A systems will accommodate connection of a maximum of 4 Expansion Modules, and the 110A through 1200A systems will accommodate connection of a maximum of 6 Expansion Modules.
Certain ampere size Safety Isolation System Power Panels can accommodate either 1 or 2 Expansion Modules installed internally. In all other instances the Expansion Module(s) must be located external to the Safety Isolation System in a suitably rated enclosure.
N ote: The time delay feature affects all input devices wired to the Expansion Module.
For Expansion Module(s) Factory Installed:
Add One of the Following Catalogue Number Strings to
the Safety Isolation System Catalogue Number:
N umber of Expansion Modules
Number of Ports per Expansion Module
Catalogue N umber String O
One (available on
Bulletin 2031, 2032,
or 2033, 110A-1200A Systems only)
4
-1EUF
4 w/time delay
-1EU FTDA
10
-1EUT
10 w/time delay
-1EUTTDA
Two (available on 630A - 1200A Bulletin 2032 or 2033 Systems only)
4
-2EUF
4 w/time delay
-2EU FTDA
10
-2EUT
10 w/time delay
-2EUTTDA
O e.g Catalogue N umber 2032T-A 0630jB-30L becomes Catalogue N umber 2032T-A 0630jB-30L-2EU T to indicate a 630A Safety Isolation System that indudes2 internally installed 10 port Ecpanson Moduleswithout the time delay feature.
Open Type Expansion Module for Field Addition
Ampere Size of Safety Isolation System
Internal Provisions to Accommodate Expansion Modules
23A - 85A
None
110A - 420A
Provisions to accept one (1) Expansion Module (Bulletins 2031, 2032 or 2033)
630A - 1200A
Provisions to accept up to two (2) Expansion Modulesin Bulletin 2032 or 2033 combination systems, or one (1) Expansion Module in Bulletin 2031 non combination systems.
Open Type ©
Description
Catalogue Number
4 port
2030-EUNF
4 port w/ time delay
2030-EUNF-1TDA
10 port
2030-EUNT
10 port w/time delay
2030-EUNT-1TDA
© Requires user supplied enclosure if not installed in the Safety Isolation System Power Panel.
© To order the Status Communication to a remote PLC option installed in an enclosed Expanson Module, add one of the followingCatalogue Strings to the Expansion Module Catalogue Number:
Expansion Modules may be ordered with an adustable time delay feature (1-30 seconds) in order to allow time for the machine operator to shut-down drives or other equipment that requires a controlled stop after a Remote Lockout Station has been switched to the "Off " position. Consult your Rockwell Automation sales office for other time settings.
Enclosed Expansion Modules are available with optional "Flex" modules to provide status communication to a remote PLC. Communication can be via DeviceNet or Remote I /O.
N ote: The status communication option allows a remote PLC to receive status signals from the Expansion Module. The Expansion Module does not accept input signals from DeviceNet or Remote I/O.
Communication
Number of I/O
Catalogue
Platform
Points
Number String G
Remote I/O
16 points
-1COM
DeviceNet
16 points
-1DNET
0 e.g Catalogue Number 2030-BJ.F becomes Catalogue Number 2030-BJ.F-1COM to indcate a Type 12 enclosed, 4-port expansion module, with 16 points of remote I/O.
To order the optional enclosed Expansion Module for field addition for North America:
Catalogue N umber ©
Description
Type 1 Enclosure
Type12 Enclosure
Type 4 Painted Enclosure
Type 4X Stainless Steel Enclosure
4 port
2030-EUAF
2030-EUJF
2030-EUFF
2030-EUCF
4 port w/ time delay
2030-EUAF-1TDA
2030-EUJF-1TDA
2030-EUFF-1TDA
2030-EUCF-1TDA
10 port
2030-EUAT
2030-EUJT
2030-EU FT
2030-EUCT
10 port w/time delay
2030-EUAT-1TDA
2030-EUJT-1TDA
2030-EUFT-1TDA
2030-EUCT-1TDA
To order the optional enclosed Expansion Module for field addition for outside of North America:
Catalogue N umber ©
Description
IP30 Enclosure
IP54 Enclosure
IP65 Enclosure
4 port
2030-EUPF
2030-EUHF
2030-EUWF
4 port w/ time delay
2030-EUPF-1TDA
2030-EUHF-1TDA
2030-EUWF-1TDA
10 port
2030-EUPT
2030-EUHT
2030-EUWT
10 port w/time delay
2030-EUPT-1TDA
2030-EUHT-1TDA
2030-EUWT-1TDA
12-16
© Allen-Bradley
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
pdf-page pdf di En 2008-10-41-11