Safety Isolation System

ElectroGuard

Combination Systems with Thermal-magnetic Circuit BreakerProduct Selection for Outside of North America (see page 12-19 for Ordering Instructions)

Ampere Rating (AC-3)3-Phase Max. kW Rating (50Hz)Catalogue Number 230V400V500V600VIP 30 EnclosureIP 54 EnclosureIP 54 Motor control centre Type Enclosure (w/bussing)IP 65 Enclosure 2033-C0420P
⊗ -61K2033-C0420H
⊗ -61K2033- 0420H
⊗ -61K2033-C0420W
⊗ -61K -220220- 2033-C0420P
⊗ -62K2033-C0420H
⊗ -62K2033- 0420H
⊗ -62K2033-C0420W
⊗ -62K --250- 2033-C0420P
⊗ -63K2033-C0420H
⊗ -63K2033- 0420H
⊗ -63K2033-C0420W
⊗ -63K 420-200-- --300- 2033-C0420P
⊗ -64K2033-C0420H
⊗ -64K2033- 0420H
⊗ -64K2033-C0420W
⊗ -64K ---355 2033-C0420P
⊗ -65K2033-C0420H
⊗ -65K2033- 0420H
⊗ -65K2033-C0420W
⊗ -65K ---390 2033-C0420P
⊗ -66K2033-C0420H
⊗ -66K2033- 0420H
⊗ -66K2033-C0420W
⊗ -66K ---425 2033-C0420P
⊗ -67K2033-C0420H
⊗ -67K2033- 0420H
⊗ -67K2033-C0420W
⊗ -67K 2033*-C0630P
⊗ -58K2033*-C0630H
⊗ -58K2033- 0630H
⊗ -58K2033*-C0630W
⊗ -58K 160--- 2033*-C0630P
⊗ -59K2033*-C0630H
⊗ -59K2033- 0630H
⊗ -59K2033*-C0630W
⊗ -59K 185--- 2033*-C0630P
⊗ -60K2033*-C0630H
⊗ -60K2033- 0630H
⊗ -60K2033*-C0630W
⊗ -60K 200--- 2033*-C0630P
⊗ -61K2033*-C0630H
⊗ -61K2033- 0630H
⊗ -61K2033*-C0630W
⊗ -61K -250-- 2033*-C0630P
⊗ -63K2033*-C0630H
⊗ -63K2033- 0630H
⊗ -63K2033*-C0630W
⊗ -63K 630150--- -300-- 2033*-C0630P
⊗ -64K2033*-C0630H
⊗ -64K2033- 0630H
⊗ -64K2033*-C0630W
⊗ -64K -355355- 2033*-C0630P
⊗ -65K2033*-C0630H
⊗ -65K2033- 0630H
⊗ -65K2033*-C0630W
⊗ -65K --390- 2033*-C0630P
⊗ -66K2033*-C0630H
⊗ -66K2033- 0630H
⊗ -66K2033*-C0630W
⊗ -66K --450450 2033*-C0630P
⊗ -68K2033*-C0630H
⊗ -68K2033- 0630H
⊗ -68K2033*-C0630W
⊗ -68K ---500 2033*-C0630P
⊗ -69K2033*-C0630H
⊗ -69K2033- 0630H
⊗ -69K2033*-C0630W
⊗ -69K 2033*-C0860P
⊗ -63K2033*-C0860H
⊗ -63K2033- 0860H
⊗ -63K2033*-C0860W
⊗ -63K -450-- 2033*-C0860P
⊗ -68K2033*-C0860H
⊗ -68K2033- 0860H
⊗ -68K2033*-C0860W
⊗ -68K 860250--- -500500- 2033*-C0860P
⊗ -69K2033*-C0860H
⊗ -69K2033- 0860H
⊗ -69K2033*-C0860W
⊗ -69K --560560 2033*-C0860P
⊗ -70K2033*-C0860H
⊗ -70K2033- 0860H
⊗ -70K2033*-C0860W
⊗ -70K ---600 2033*-C0860P
⊗ -71K2033*-C0860H
⊗ -71K2033- 0860H
⊗ -71K2033*-C0860W
⊗ -71K 2033*-C1200P
⊗ -64K2033*-C1200H
⊗ -64K2033- 1200H
⊗ -64K2033*-C1200W
⊗ -64K 390--- 2033*-C1200P
⊗ -66K2033*-C1200H
⊗ -66K2033- 1200H
⊗ -66K2033*-C1200W
⊗ -66K -600600- 2033*-C1200P
⊗ -71K2033*-C1200H
⊗ -71K2033- 1200H
⊗ -71K2033*-C1200W
⊗ -71K -710710710 2033*-C1200P
⊗ -72K2033*-C1200H
⊗ -72K2033- 1200H
⊗ -72K2033*-C1200W
⊗ -72K 1200300--- --750750 2033*-C1200P
⊗ -73K2033*-C1200H
⊗ -73K2033- 1200H
⊗ -73K2033*-C1200W
⊗ -73K --850850 2033*-C1200P
⊗ -74K2033*-C1200H
⊗ -74K2033- 1200H
⊗ -74K2033*-C1200W
⊗ -74K --888888 2033*-C1200P
⊗ -75K2033*-C1200H
⊗ -75K2033- 1200H
⊗ -75K2033*-C1200W
⊗ -75K ---1043 2033*-C1200P
⊗ -76K2033*-C1200H
⊗ -76K2033- 1200H
⊗ -76K2033*-C1200W
⊗ -76K

To order the Time Delay feature, add the following Catalogue String to the end of the Cat. No. shown in the table:

Factory set 30 second time delay feature: -1TDInput Power FeedCatalogue Number Code Example : Catalogue Number 2033-C0180P
⊗ -54K becomes Catalogue Number 2033-C0180P
⊗ -54K-1TD to include the time delay feature.

* Input Power Feed Catalogue Number Code The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.

Example : Catalogue Number 2033*-C0630P
⊗ -58K becomes Catalogue Number 2033T-C0630P
⊗ -58K for a “Top Feed” input power requirement. Top Feed T Bottom Feed B
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position. Consult your local Rockwell Automation sales office for other time settings.

12-14

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
pdf-page pdf di En 2008-10-42-14