| | | CENTERLINE® Motor Control Centers Bulletin 2400 Application-Rated Units | | |
| | | |
| | | BULLETIN 2403 Combination Full Voltage Contactor with Circuit Breaker (FVC) | | |
| | | |
| | | | | | | | | | | | | | | | | Control Voltage Code | Control Type | | | | 220V | 230V | 240V | 380V | 400V | 415V | 480V | 600V | | | | — | — | A | — | — | — | B | C | 120V, 60Hz Transformer Control [1] | | | | — | — | AD | — | — | — | BD | CD | 120V, 60Hz Separate Control [2] | | | | P | — | — | N | — | I | — | — | 110V, 50Hz Transformer Control [11'[3] | | | | PS | — | — | NS | — | IS | — | — | 110V, 50Hz Separate Control [2] | | | | — | P | — | — | KN | — | — | — | 115V, 50HZ Transformer Control [1L[31 | | | | — | PS | — | — | KNS | — | — | — | 115V, 50Hz Separate Control [2] | | | | — | — | — | NP | — | — | — | — | 220V, 50Hz Transformer Control [11'[3] | | | | — | — | — | NP | — | — | — | — | 220V, 50Hz Separate Control [2] | | | | — | — | — | — | KNP | — | — | — | 230V, 50Hz Transformer Control [11'[3] | | | | — | — | — | — | KNP | — | — | — | 230V, 50Hz Separate Control [2] | | | | — | — | — | — | — | IT | — | — | 240V, 50Hz Transformer Control [11'[3] | | | | — | — | — | — | — | IT | — | — | 240V, 50Hz Separate Control [2] | | | | — | — | — | NLP | — | — | — | — | 220V, 50Hz Line to Neutral Control (Separate Control) [4№1 | | | | — | — | — | — | KNLP | — | | — | 230V, 50Hz Line to Neutral Control (Separate Control) [4№1 | | | | | — | — | — | — | ILT | | — | 240V, 50Hz Line to Neutral Control (Separate Control) [4№1 | | | | | | | | | | | | | | | | |
| | | |
| | | [1] Select a control circuit transformer. See Options section beginning on page 26. [2] Control circuit fusing (option 21) and/or disconnect interlock (option 98) may be required to comply with NEC/CEC. See Options section beginning on page 26. [3] Incorporates primary industrial taps for future conversion to new global IEC voltage standards (e.g., 400V/115V/230V). Allows conversion without the need to replace transformers or coils. [4] Requires horizontal neutral bus and vertical neutral bus in 9" (228.60 mm) vertical wireway. Refer to publication 2100-PL001x-EN-P, Section Modifications, to select. [5] Select control circuit fusing (option 21 in Options section beginning on page 30). | | |
| | | |
| | | | | | | | | | | | | | Contactor Rating (Amps) | Number | Trip Current (Amps) | Contactor Rating (Amps) | Number | Trip Current (Amps) | | | | 30 | 30 31 | 15 20 | 100 or 200 | 40 | 100 | | | | 30 or 60 | 32 | 30 | 200 or 300 | 41 42 43 44 | 125 150 175 200 | | | | 60 or 100 | 34 35 36 | 40 50 60 | 300 | 45 46 48 | 225 250 300 | | | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | | | Rating (Amperes) | Standard Interrupting Capacity [1] | Medium Interrupting Capacity [1] | High Interrupting Capacity [1] | | | | 30-60 | CT | FDB | CB | FD | CM | HFD | | | | 100 | CT | FDB | CB | FD | CM | HFD | | | | 200 | CT | JD | — | — | CM | HJD | | | | 300 | CT | KD | — | — | CM | HKD | | | | | | | | | | | | | | |
| | | |
| | | [1] See Appendix (page 34) for circuit breaker interrupting capacity and short circuit withstand ratings. Non-interchangeable circuit breakers. | | |
| | | |
| | | Publication 2400-CA001B-EN-P—September 2005 17 | | |
| | | For Options, Modifications, and Accessories, see page 26 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | |