| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | General Information i | | | | | | 1 | | | | | | | | | | | | | | Delivery Programs | | | | | | The Bulletin 2100 DeviceNet system (power supply unit, built-in cabling system, unit cables, etc.) is UL and cUL listed and meets the requirements of a class 1 power limited circuit (in Canada, class 1 extra-low-voltage power circuit). Per NEC, this circuit is supplied from a source that has a rated output of not more than 30 Volts and 1000 Volt-Amperes. The power supply unit has an 8A, 24V output and the DeviceNet cabling is rated 8A, 600V. See NEC Article 725 for more detailed information. Type 2 Protection Short circuit coordination is defined in IEC 60947-4-1. Type 2 protection (also referred to as Type 2 coordination) is obtainable when the industrial fuses are specified and sized according to publication 100-2.8, Certified Type 2 Short Circuit Coordination with Allen-Bradley Motor Starters. Only Type 1 coordination is available on other than specified fuses and industrial circuit breaker units. | | | | | | | | | | Bulletin 2100 products are available on several quick delivery programs and limited to equipment described in this publication. SC and PE: Products indicating SC or PE delivery provide SC-I and PE-I delivery. When options are added or specified for a section, time of delivery is determined by the longest lead time. SC-I: This program offers stock-supported, individual plug-in units as well as vertical sections with field installed plug-in units. This program applies to all plug-in units and vertical sections unless they are labeled SC-II. The SC-I program provides the quickest delivery. SC-II: This program offers stock-supported vertical sections, with factory-installed units for a completely assembled MCC. This is either SC or SC-II. Units specifically labeled SC-II must be factory installed and are not for plug-in installation in the field. PE-I and PE-II: Shading indicates equipment that is offered on the PE-I or PE-II program. These programs offer a broad range of pre-engineered units and sections and a slightly longer lead time than our SC programs. While PE-I units are available for plug-in installation in the field, units specifically labeled PE-II must be factory installed. Engineered: Equipment or modifications not available on the above delivery programs may be available on the Engineered program. This program offers the complete line of assembled motor control equipment, custom wired for the customer's needs. Additionally, a wide range of special control and bus options are offered, making this our most versatile delivery program. Contact your local Rockwell Automation Sales Office or Allen-Bradley distributor for more information. Delivery Time will be based equipment with the longest lead time on the item. Quicker delivery is possible when equipment is separated and ordered according to the delivery category. For example, if an order has one engineered plug-in unit and the remaining units and sections are SC-II - order the engineered unit as a separate item. The SC-II units and sections will ship on the SC-II delivery program, and only the engineered unit will have a longer delivery time. Delivery Program Indications Delivery programs are indicated in the right column on all configuration pages. PE delivery program is indicated by blue type. | | | | | | | | | | Motor Applications | | | | | | | | | | The Motor Control Center Business has made engineering evaluations for the protective device (circuit breaker or fuse) selection, sizing, and setting range based on the protection rules/requirements and motor criteria as stipulated in NEC, NEMA, and UL standards (e.g., motor full load currents [FLCs], X/R ratios, lock rotor currents, nominal utilization voltages, etc.). Should the motor application have criteria that deviate from those stated in the aforementioned standards, higher FLC and/or motor inrush currents (greater than 1300% of the nominal FLC) may be experienced (e.g., special motors, non-standard NEMA motors, energy efficient motors, Design E motors, IEC Type N motors, etc.). To address these cases, consult publications 2100-TD001x-EN-P and 2100-TD002x-EN-P (for circuit breaker applications), publication 2100-TD003x-EN-P (for power fuse applications), and the NEC for selection guidance. Should additional guidance or information be needed, contact your local Rockwell Automation Sales Office. Documentation For assembled motor control centers, the customer is supplied with a copy of the motor control center layout and specification (Form 385) and publication 2100-5.0, Bulletin 2100 CENTERLINE Motor Control Centers Instruction Manual. Publication 2100-IN040x-EN-P, Receiving, Handling, and Storing Motor Control Centers, is attached to the outside packaging of each shipping block. Information on field termination and bus torquing instructions are located on the inside of each vertical wireway door. Documentation for individual units consists of a copy of the unit wiring diagram and installation instructions. This documentation may be located in a centralized wiring diagram holder or other location depending on configuration. Manuals supplied by Richland Center for SMC units, Ac drive units, PLC units, etc. are included in the diagram pocket of each MCC containing these products. For other documentation, consult your local Rockwell Automation sales representative. | | | | | | | | | | | | | | | | | Catalog Number Wiring Type B—Class 1 NEMA Type 1 and Type 1 w/ gasket | Delivery Program | | | | 2112B-FA_-_ | SC | | | | 2112BB-GA_-_ | PE-II | | | | | | | | | | | | | | | | | Post Shipment Support | | | | | | | | | | | | | | Service and Storage Conditions CENTERLINE MCCs conform to NEMA standard ICS 1-1993 for service and storage conditions. All MCCs should have an ambient operating temperature above 0oC but shall not exceed 40oC with up to 95% non-condensing humidity. If the equipment is stored, the ambient temperature shall be above -30oC but shall not exceed 65oC. In addition, MCCs have an altitude class of 2km. The altitude class of 2 km designates equipment for installation where the altitude does not exceed 2000 meters (6600 feet). For installation above 2000 meters, Contact your local Rockwell Automation Sales Office for derating requirements. Device Products DeviceNet Look for the DeviceNet logo throughout this book to find units and options that are DeviceNet ready to use in the IntelliCENTER or Bulletin 2100 DeviceNet MCCs. The components used in these units are DeviceNet compatible and ODVA certified. Also, the installation conforms to the rules and guidelines of The Planning and Installation Manual for DeviceNet. | | | | | | • Field Service • Field Complaints • Repair & Modifications • Technical Issues • GMC Code 10 Authorization • Warranty Issues • Domestic and International Renewal Parts Order Services CENTERLINE MCC: Email: RAMCCSupport@ra.rockwell.com Fax: 1-414- 382-4045 Phone: 1-440-646-5800 Select Options 2, 5, 1 for Allen-Bradley Brand Products, Motor Control Centers, Hardware Support IntelliCENTER MCC: Email: RAICTechSupport@ra.rockwell.com Fax: 1-414- 382-0505 Phone: 1-440-646-5800 Select Options 2, 5, 2 for Allen-Bradley Brand Products, Motor Control Centers, IntelliCENTER Support | | | | | | | | | | | | | | 3 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|