Catalogue CENTERLINE® Motor Control Centers
www.rockwellautomation.fr
print switch display
Page / 266
Make a request   
ROCKWELL AUTOMATION - 14318, 2753
/ 266
See other catalogues for ROCKWELL AUTOMATION
Text version of the page
Contactor and Starter Units
Bulletin 2123E
Two Speed 2-Winding Starter Unit with Industrial circuit breaker (TS2W)
See page 31 for product description.
Note: A two-speed 2-winding motor (TS2W) requires a mechanically and electrically interlocked assembly of two 3-pole contactors. A two-speed 1-winding motor (TS1W) requires a mechanically and electrically interlocked assembly of 3-pole and 5-pole contactors. Consult your local Rockwell Automation Sales Office for application assislance.H^^^^^^^^^^^H^^H^^^^^H^^^^^^^^^^^^^B^^^^^^^^^^
NEMA Size
Constant or Variable Torque Line Voltage
Space
Catalog Number [1] Wiring Type B—Class I
Delivery
208V Hp
240V Hp
380V-415V
Hp
480V/600V
Hp
Factor
NEMA Type 1 and Type 1 w/ gasket
NEMA Type 12
Program
1
0.125-7.5
0.125-7.5
0.125-10
0.125-10
2.0
2123EB-BA_-_
2123EB-BD_-_
2
10
10-15
15-25
15-25
2.0
2123EB-CA_-_
2123EB-CD_-_
SC
3
15-25
20-30
30-50
30-50
3.0
2123EB-DA_-_
2123EB-DD_-_
4
30-40
40-50
60-75
60-100
4.5
2123EB-EA_-_
2123EB-ED_-_
PE
5 H
50-75
60-100
100-150
125-200
6.0
2123EB-FA_-_
2123EB-FD_-_
PE-II
[1] The catalog numbers listed are not complete:
• Select the control voltage type from table on page 205 (e.g., 2123EB-BABD).
• Select the horsepower from table on page 206 (e.g., 2123EB-BABD-30).
• Select the circuit breaker from Circuit Breaker Type table on page 211 (e.g., 2123EB-BABD-30CA).
• For circuit breaker size based on load horsepower, refer to publications 2100-TD001x-EN-P and 2100-TD002x-EN-P.
The catalog numbers listed include an external reset button for the overload relay. To order catalog numbers without the external reset button, replace the letter
"A" with the letter "K" (e.g., 2123EB-BK_-_) or replace the letter "D" with the letter "J" (e.g., 2123EB-BJ_-_).
[2] If low speed full load current is below 77A, a special starter is required. Contact your local Rockwell Automation Sales Office.
Bulletin 2123F
Two Speed 1-Winding Starter Unit with Circuit Breaker (TS1W)
See page 31 for product description.
Note: A two-speed 1-winding motor (TS1W) requires a mechanically and electrically interlocked assembly of 3-pole and 5-pole contactors. A two-speed 2-winding motor (TS2W) requires a mechanically and electrically interlocked assembly of two 3-pole contactors. Consult your local Rockwell Automation Sales Office for application assistance.
NEMA
Constant or Variable Torque Line Voltage
Space
Catalog Number [1] Wiring Type B—Class I
Delivery
Size
208V
Hp
240V
Hp
380V-415V
Hp
480V/600V
Hp
Factor
NEMA Type 1 and Type 1 w/ gasket
NEMA Type 12
Program
1
0.125-7.5
0.125-7.5
0.125-10
0.125-10
2.0
2123FB-BA_-_
2123FB-BD_-_
2
10
10-15
15-25
15-25
2.0
2123FB-CA_-_
2123FB-CD_-_
SC
3
15-25
20-30
30-50
30-50
3.5
2123FB-DA_-_
2123FB-DD_-_
4
30-40
40-50
60-75
60-100
4.5
2123FB-EA_-_
2123FB-ED_-_
5 H
50-75
60-100
100-150
125-200
6.0
25" W
2123FB-FA_-__
2123FB-FD_-__
PE-II
[1] The catalog numbers listed are not complete:
• Select the control voltage type from table on page 205 (e.g., 2123FB-BABD).
• Select the horsepower from table on page 206 (e.g., 2123FB-BABD-30).
• Select the circuit breaker from Circuit Breaker Type table on page 211 (e.g., 2123FB-BABD-30CA).
• For circuit breaker size based on load horsepower, refer to publications 2100-TD001x-EN-P and 2100-TD002x-EN-P.
The catalog numbers listed include an external reset button for the overload relay. To order catalog numbers without the external reset button, replace the letter
"A" with the letter "K" (e.g., 2123FB-BK_-_) or replace the letter "D" with the letter "J" (e.g., 2123FB-BJ_-_).
[2] If low speed full load current is below 77A, a special starter is required. Contact your local Rockwell Automation Sales Office.
For Options, Modifications, and Accessories, see pages 101-117 45
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-150
151-200
201-250
251-266
pdf-page pdf di En 2008-10-42-14