Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | Contactor and Starter Units | | | | | | | | | | Bulletin 2106 See page 31 for product description. | | | | | | | | | | | | | | | | | | | | | | | | | | NEMA | Line Voltage | Fuse Clip (See Appendix for short circuit withstand ratings.) | Space | Catalog Number [1] Wiring Type B—Class I | Delivery | | | | Size | 208V Hp | 240V Hp | 380V-415V Hp | 480V/ 600V Hp | Rating (Amperes) | Class | Factor | NEMA Type 1 and Type 1 w/ gasket | NEMA Type 12 | Program | | | | 1 | 0.125-7.5 | 0.125-7.5 | 0.125-10 | 0.125-10 | 30 | CC, J, R, H, HRCII-C | 1.5 | 2106B-BA_-_ | 2106B-BD_-_ | | | | | | | | | | 60 | J, R, H, HRCII-C | | | | | | | | 2 | 10 | 10-15 | | 15-25 | 30 [2] 60 100 | J, R, H, HRCII-C J, R, H, HRCII-C J | 1.5 | 2106B-CA_-_ | 2106B-CD_-_ | | | | | | | | | | 100 | R, H, HRCII-C | 2.0 [3] | | | SC | | | | 3 | 15-25 | 20-30 | | 30-50 | 60 [2] 100 200 | J, R, H, HRCII-C J, R, H, HRCII-C J, R, H, HRCII-C | 3.0 | 2106B-DA_-_ | 2106B-DD_-_ | | | | | 4 | 30-40 | 40-50 | | 60-100 | 100 [2] 200 400 | J, R, H, HRCII-C J, R, H, HRCII-C J | 4.0 | 2106B-EA_-_ | 2106B-ED_-_ | | | | | 5 | 50-75 | 60-100 | 100-150 | 125-200 | 200 [2] 400 600 | J, R, H, HRCII-C J, R, H, HRCII-C J | 6.0 | 2106B-FA_-__ | 2106B-FD_-__ | PE-II | | | | | | | | | | | | | | | | | | | | | | | | | | [1] The catalog numbers listed are not complete: • Select control voltage type from table on page 205 (e.g., 2106B-BABD). • Select horsepower from table on page 206 (e.g., 2106B-BABD-31). • If power fuse will NOT be selected, select fuse clip from table above. Then select clip designator from table on page 207 (e.g., 2106B-BABD-31-24J). • If power fuse WILL be selected, first select clip designator from table on page 207 (e.g., 2106B-BABD-31_-20J). Then select power fuse from table on page 207 (e.g., 2106B-BABD-31GT-20J). • For fuse rating based on load horsepower, see publication 2100-TD003x-EN-P. The catalog numbers listed include an external reset button for the overload relay. To order catalog numbers without the external reset button, replace the letter "A" with the letter "K" (e.g., 2106B-BK_-_) or replace the letter "D" with the letter "J" (e.g., 2106B-BJ_-_). [2] Available on 480V and 600V applications only. [3] For 208V and 240V applications with Class R or H fuses, unit only requires 1.5 space factors. | | | | | | | | | | Bulletin 2107 See page 31 for product description. | | | | | | | | | | | | | | | | | | | | | | | | NEMA Size | Line Voltage | Space | Catalog Number [1] Wiring Type B—Class I | Delivery | | | | 208V Hp | 240V Hp | 380V-415V Hp | 480V/600V Hp | Factor | NEMA Type 1 and Type 1 w/ gasket | NEMA Type 12 | Program | | | | 1 | 0.125-7.5 | 0.125-7.5 | 0.125-10 | 0.125-10 | 1.5 | 2107B-BA_-_ | 2107B-BD_-_ | | | | | 2 | 10 | 10-15 | 15-25 | 15-25 | 1.5 | 2107B-CA_-_ | 2107B-CD_-_ | SC | | | | 3 | 15-25 | 20-30 | 30-50 | 30-50 | 3.0 | 2107B-DA_-_ | 2107B-DD_-_ | | | | 4 | 30-40 | 40-50 | 60-75 | 60-100 | 4.0 | 2107B-EA_-_ | 2107B-ED_-_ | | | | | 5 | 50-75 | 60-100 | 100-150 | 125-200 | 6.0 | 2107B-FA_-_ | 2107B-FD_-_ | PE-II | | | | | | | | | | | | | | | | | | | | | | | | [1] The catalog numbers listed are not complete: • Select control voltage type from table on page 205 (e.g., 2107B-BABD). • Select horsepower from table on page 206 (e.g., 2107B-BABD-30). • Select circuit breaker type from Circuit Breaker Type table on page 211 (e.g., 2107B-BABD-30CA). • For circuit breaker size based on load horsepower, refer to publications 2100-TD001x-EN-P and 2100-TD002x-EN-P. The catalog numbers listed include an external reset button for the overload relay. To order catalog numbers without the external reset button, substitute the letter "A" for the letter "K" (e.g., 2107B-BK_-_) or replace the letter "D" with the letter "J" (e.g., 2107B-BJ_-_). | | | | | | | | | | For Options, Modifications, and Accessories, see pages 101-117 37 | | | | | | | | | | | | | | | | | | | | | |
|