| | | | | | | | | | | | | | | | | | | | | Contactor and Starter Units | | | | | | | | | | Bulletin 2102L • See page 31 for product description. • For unit sizing, select unit rating based on 125% of actual load amperes. Note: In order to address the heating effects from loads containing a high degree of harmonic content, it may be necessary to oversize the field conductors (especially neutrals), use k-factor lighting industrial transformers, and oversize the lighting contactor units (increase by 50%); for high harmonic load applications, Contact your local Rockwell Automation Sales Office. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Rating (Amperes) [1] | Transformer Primary Switching kVA [2] | Fuse Clip (See Appendix for short circuit withstand ratings.) | Space Factor | Catalog Number [3] Wiring Type B—Class I | Delivery Program | | | | 208V | 240V | 380V-415V | 480V | 600V | NEMA Type 1 and Type 1 w/ gasket | NEMA Type 12 | | | | 10 | 30 | 10 | 30 | 10 | 30 | 10 | 30 | 10 | 30 | Rating (Amperes) | Class | | | | 30[4] | 1.2 | 3.6 | 2.4 | 4.3 | 2.8 | 7.1 | 4.9 | 8.5 | 6.2 | 11 | 30 | CC, J | 0.5 | 2102LB-ZK_-_ | 2102LB-ZJ_-_ | SC | | | | 30 | 1.2 | 3.6 | 2.4 | 4.3 | 2.8 | 7.1 | 4.9 | 8.5 | 6.2 | 11 | 30 | CC, J, R, H | 1.0 | 2102LB-BK_-_ | 2102LB-BJ_-_ | | | | 60 | 2.1 | 6.3 | 4.1 | 7.2 | 6.8 | 11.8 | 8.3 | 14 | 10 | 18 | 30 60 | J, R, H | 1.0 | 2102LB-CK_-_ | 2102LB-CJ_-_ | | | | 100 | 4.1 | 12 | 8.1 | 14 | 13.3 | 23.3 | 16 | 28 | 20 | 35 | 60 100 | J, R, H | 2.5 | 2102LB-DK_-_ | 2102LB-DJ_-_ | | | | 200 | 6.8 | 20 | 14 | 23 | 22.5 | 39 | 27 | 47 | 34 | 59 | 100 200 | J, R, H | 3.0 | 2102LB-EK_-__ | 2102LB-EJ_-__ | | | | | 300 | 14 | 41 | 27 | 47 | 45 | 78.3 | 54 | 94 | 68 | 117 | 200 400 | J, R, H | 4.0 | 2102LB-FK_-__ | 2102LB-FJ_-__ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | [1] Ampere ratings apply to non-motor loads such as fluorescent ballasts, mercury vapor lamps, and resistive heating. Tungsten lamp current ratings are limited to applications 480 volts line-to-line (277 volts line-to-neutral) maximum. [2] Ratings are based on the contactor being used to switch transformers having an inrush of not more than 20 times their rated full load current, regardless of the nature of the secondary load. Ratings do not apply to transformers used in resistance welder manufacturer service. [3] The catalog numbers listed are not complete: • Select control voltage type from table on page 205 (e.g., 2102LB-BKBD). • Then select designator from table on page 208 (e.g., 2102LB-BKBD-24J). • To select optional power fuse, select from table on page 208 (e.g., 2102LB-BKBD-24J-607G). • For fuse rating, based on disconnect rating see publication 2100-TD003x-EN-P. [4] Separate or transformer control only, except 208V (where separate control only). These units have horizontal handles, Bulletin 194R fused molded case switch, up to three (3) Bulletin 800E pilot devices, and one (1) 7-pt. pull-apart control terminal block with #16 AWG control wire only. One (1) 3-pole power terminal block is supplied as standard. | | | | | | | | | | 34 For Options, Modifications, and Accessories, see pages 101-117 | | | | | | | | | | | | | | | | | | | | |
|