Vertical Sections 2
Vertical Sections With Industrial circuit breaker (SC) (Without Vertical Wireway)
?Maximum SC shipping block is one (1) vertical section.? End
closing plates are supplied.?Splice kits are not included .?
Industrial enclosures without horizontal bus are UL listed to the UL Standard for Safety UL 508 unless otherwise indicated, short circuit interrupting capacity marking does not apply.?Line side of circuit breaker is connected to horizontal bus for sections with horizontal bus. >
? Customer cables connect to line side of circuit breaker for sections without horizontal bus >
. Section NEMA Type 1 NEMA Type 12 Description Working Depth (Inches) Delivery Program Depth (Inches) Width (Inches) CatalogNumber CatalogNumber 2100-GKC1_1D-_ _-_ _ >
[1] 2100-GJC1_1D-_ _-_ _ >
[1] 2100-GKC1_2D-_ _-_ _ >
[1] 2100-GJC1_2D-_ _-_ _ >
[1] 30 2100-GKC1_3D-_ _-_ _ >
[1] 2100-GJC1_3D-_ _-_ _ >
[1] 8.5 (withhorizontal bus)1520 35 2100-GKC1_4D-_ _-_ _ >
[1] 2100-GJC1_4D-_ _-_ _ >
[1] 2100-GKC2_1D-_ _-_ _ >
[1] 2100-GJC2_1D-_ _-_ _ >
[1] 25 2100-GKC2_2D-_ _-_ _ >
[1] 2100-GJC2_2D-_ _-_ _ >
[1] 2020 30 2100-GKC2_3D-_ _-_ _ >
[1] 2100-GJC2_3D-_ _-_ _ >
[1] 35 2100-GKC2_4D-_ _-_ _ >
[1] 2100-GJC2_4D-_ _-_ _ >
[1] 2100-GKC2_1A-_ _-_ _ >
[1] 2100-GJC2_1A-_ _-_ _ >
[1] 11.5 (withhorizontal bus) 25 2100-GKC2_2A-_ _-_ _ >
[1] 2100-GJC2_2A-_ _-_ _ >
[1] 2020 >
VerticalSectionIncludes full six (6.0) space factor door and mounting plate. With disconnecting means.
No vertical wireway. See page 235 for circuit breaker interrupting capacityAdding equipment to these sections may void UL and C-UL/CSA certification.
[2] 30 2100-GKC2_3A-_ _-_ _ >
[1] 2100-GJC2_3A-_ _-_ _ >
[1] 35 2100-GKC2_4A-_ _-_ _ >
[1] 2100-GJC2_4A-_ _-_ _ >
[1] 2100-GKC2_1B-_ _-_ _ >
[1] 2100-GJC2_1B-_ _-_ _ >
[1] 14(withhorizontal bus) 25 2100-GKC2_2B-_ _-_ _ >
[1] 2100-GJC2_2B-_ _-_ _ >
[1] [2] 2020 30 2100-GKC2_3B-_ _-_ _ >
[1] 2100-GJC2_3B-_ _-_ _ >
[1] 35 2100-GKC2_4B-_ _-_ _ >
[1] 2100-GJC2_4B-_ _-_ _ >
[1] [3] [3] SC
25 2100-GKC1_1A-_ _ 2100-GJC1_1A-_ _ 25 2100-GKC1_2A-_ _ >
[3] 2100-GJC1_2A-_ _ >
[3] 30 2100-GKC1_3A-_ _ >
[3] 2100-GJC1_3A-_ _ >
[3] 11.5(without horizontal bus)1520 35 2100-GKC1_4A-_ _ >
[3] 2100-GJC1_4A-_ _ >
[3] 2100-GKC2_1A-_ _ >
[3] 2100-GJC2_1A-_ _ >
[3] 25 2100-GKC2_2A-_ _ >
[3] 2100-GJC2_2A-_ _ >
[3] 2020 30 2100-GKC2_3A-_ _ >
[3] 2100-GJC2_3A-_ _ >
[3] 35 2100-GKC2_4A-_ _ >
[3] 2100-GJC2_4A-_ _ >
[3] 2100-GKC1_1B-_ _ >
[3] 2100-GJC1_1B-_ _ >
[3] 14(withouthorizontal bus)1520 25 2100-GKC1_2B-_ _ >
[3] 2100-GJC1_2B-_ _ >
[3] 30 2100-GKC1_3B-_ _ >
[3] 2100-GJC1_3B-_ _ >
[3] 35 2100-GKC1_4B-_ _ >
[3] 2100-GJC1_4B-_ _ >
[3] 2100-GKC2_1C-_ _ >
[3] 2100-GJC2_1C-_ _ >
[3] 19(withouthorizontal bus)2020 25 2100-GKC2_2C-_ _ >
[3] 2100-GJC2_2C-_ _ >
[3] 30 2100-GKC2_3C-_ _ >
[3] 2100-GJC2_3C-_ _ >
[3] 35 2100-GKC2_4C-_ _ >
[3] 2100-GJC2_4C-_ _ >
[3] [1]The catalog numbers listed are not complete:?Select ground bus option B, C, N, or P from table on page 12 (only horizontal ground bus is supplied; e.g., 2100-GKC1 B ). ?Select bus bar bracing, A or B, from table on page 12 (horizontal bus is provided in vertical sections; e.g., 2100-GKC1B1D- A ).?Select bus bar material and plating from table on page 12 (e.g., 2100-GKC1B1D-A AT06 ).?Select trip current number from Trip Current table on page 21 (e.g., 2100-GKC1B1D-AAT06- 30 ).?Select circuit breaker type from Inverse Time (Thermal Magnetic) Circuit Breaker Option table on page 21 (e.g., 2100-GKC1B1D-AAT06-30 CT ). [2]Horizontal bus is 5” deeper than standard. [3]The catalog numbers listed are not complete:?Select ground bus option B, C, N, or P from table on page 12 (only horizontal ground bus is supplied; e.g., 2100-GKC1 B ). ?Select trip current number from Trip Current table on page 21 (e.g., 2100-GKC1B1A- 30 ).?Select circuit breaker type from Inverse Time (Thermal Magnetic) Circuit Breaker Option table on page 21 (e.g., 2100-GKC1B1A-30 CT ). >
20 For Options, Modifications, and Accessories, see page 21